메뉴 건너뛰기




Volumn 139, Issue 10, 2013, Pages 1033-1044

Experimental investigation of coupled frequency and time-domain transient test-based techniques for partial blockage detection in pipelines

Author keywords

Frequency response analysis; Laboratory tests; Partial blockage; Pressure signal analysis; Transient analysis; Water pipelines

Indexed keywords

CALCULATION EFFICIENCY; EXPERIMENTAL APPLICATION; EXPERIMENTAL INVESTIGATIONS; FREQUENCY RESPONSE ANALYSES (FRA); FREQUENCY RESPONSE ANALYSIS; LABORATORY TEST; PARTIAL BLOCKAGE; PRESSURE SIGNAL;

EID: 84884345844     PISSN: 07339429     EISSN: None     Source Type: Journal    
DOI: 10.1061/(ASCE)HY.1943-7900.0000768     Document Type: Article
Times cited : (105)

References (33)
  • 1
    • 0037526489 scopus 로고    scopus 로고
    • Leak monitoring in pipeline networks using wavelet analysis
    • none
    • Al-Shidhani, I., Beck, S. B. M., and Staszewsky, W. J. (2003). "Leak monitoring in pipeline networks using wavelet analysis." Key Eng. Mater., 245-246(none), 51-58.
    • (2003) Key Eng. Mater. , vol.245-246 , pp. 51-58
    • Al-Shidhani, I.1    Beck, S.B.M.2    Staszewsky, W.J.3
  • 2
    • 0033197897 scopus 로고    scopus 로고
    • A transient test-based technique for leak detection in outfall pipes
    • Brunone, B. (1999). "A transient test-based technique for leak detection in outfall pipes." J. Water Resour. Plann. Manage., 125(5), 302-306.
    • (1999) J. Water Resour. Plann. Manage. , vol.125 , Issue.5 , pp. 302-306
    • Brunone, B.1
  • 3
    • 0035182798 scopus 로고    scopus 로고
    • Detecting leaks in pressurized pipes by means of transients
    • Brunone, B., and Ferrante, M. (2001). "Detecting leaks in pressurized pipes by means of transients." J. Hydraul. Res., 39(5), 539-547.
    • (2001) J. Hydraul. Res. , vol.39 , Issue.5 , pp. 539-547
    • Brunone, B.1    Ferrante, M.2
  • 4
    • 44049107131 scopus 로고    scopus 로고
    • Discussion of 'Detection of partial blockage in single pipelines'
    • by P. Mohapatra. M.H. Chaudhry, A.A. Kassem, and J. Moloo
    • Brunone, B., Ferrante, M., and Meniconi, S. (2008a). "Discussion of 'Detection of partial blockage in single pipelines' by P.K. Mohapatra, M.H. Chaudhry, A.A. Kassem, and J. Moloo." J. Hydraul. Eng., 134(6), 872-874.
    • (2008) J. Hydraul. Eng. , vol.134 , Issue.6 , pp. 872-874
    • Brunone, B.1    Ferrante, M.2    Meniconi, S.3
  • 5
    • 43649094878 scopus 로고    scopus 로고
    • Portable pressure wave-maker for leak detection and pipe system characterization
    • Brunone, B., Ferrante, M., and Meniconi, S. (2008b). "Portable pressure wave-maker for leak detection and pipe system characterization." J. Am. Water Works Assoc., 100(4), 108-116.
    • (2008) J. Am. Water Works Assoc. , vol.100 , Issue.4 , pp. 108-116
    • Brunone, B.1    Ferrante, M.2    Meniconi, S.3
  • 6
    • 63649127134 scopus 로고    scopus 로고
    • A selective literature review of transient-based leak detection methods
    • Colombo, A. F., Lee, P. J., and Karney, B.W. (2009). "A selective literature review of transient-based leak detection methods." J. Hydroenviron. Res., 2(4), 212-227.
    • (2009) J. Hydroenviron. Res. , vol.2 , Issue.4 , pp. 212-227
    • Colombo, A.F.1    Lee, P.J.2    Karney, B.W.3
  • 8
    • 79957446926 scopus 로고    scopus 로고
    • Leak detection in complex series pipelines by using system frequency response method
    • Duan, H. F., Lee, P. J., Ghidaoui, M. S., and Tung, Y. K. (2011). "Leak detection in complex series pipelines by using system frequency response method." J. Hydraul. Res., 49(2), 213-221.
    • (2011) J. Hydraul. Res. , vol.49 , Issue.2 , pp. 213-221
    • Duan, H.F.1    Lee, P.J.2    Ghidaoui, M.S.3    Tung, Y.K.4
  • 9
    • 84857186574 scopus 로고    scopus 로고
    • Extended blockage detection in pipelines by using the system frequency response analysis
    • Duan, H. F., Lee, P. J., Ghidaoui, M. S., and Tung, Y. K. (2012a). "Extended blockage detection in pipelines by using the system frequency response analysis." J. Water Resour. Plann. Manage., 138(1), 55-62.
    • (2012) J. Water Resour. Plann. Manage. , vol.138 , Issue.1 , pp. 55-62
    • Duan, H.F.1    Lee, P.J.2    Ghidaoui, M.S.3    Tung, Y.K.4
  • 10
    • 84878519686 scopus 로고    scopus 로고
    • System response function based leak detection in viscoelastic pipeline
    • Duan, H. F., Lee, P. J., Ghidaoui, M. S., and Tung, Y. K. (2012b). "System response function based leak detection in viscoelastic pipeline." J. Hydraul. Eng., 138(2), 143-153.
    • (2012) J. Hydraul. Eng. , vol.138 , Issue.2 , pp. 143-153
    • Duan, H.F.1    Lee, P.J.2    Ghidaoui, M.S.3    Tung, Y.K.4
  • 11
    • 84881284845 scopus 로고    scopus 로고
    • Extended blockage detection in pipes using the system frequency response: Analytical analysis and experimental verification
    • Duan, H. F., Lee, P. J., Kashima, A., Lu, J., Ghidaoui, M. S., and Tung, Y. K. (2013). "Extended blockage detection in pipes using the system frequency response: Analytical analysis and experimental verification." J. Hydraul. Eng., 139(7), 763-771.
    • (2013) J. Hydraul. Eng. , vol.139 , Issue.7 , pp. 763-771
    • Duan, H.F.1    Lee, P.J.2    Kashima, A.3    Lu, J.4    Ghidaoui, M.S.5    Tung, Y.K.6
  • 12
    • 0037217888 scopus 로고    scopus 로고
    • Pipe system diagnosis and leak detection by unsteady-state tests.1. Harmonic analysis
    • Ferrante, M., and Brunone, B. (2003a). "Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis." Adv. Water Resour., 26(1), 95-105.
    • (2003) Adv. Water Resour. , vol.26 , Issue.1 , pp. 95-105
    • Ferrante, M.1    Brunone, B.2
  • 13
    • 0037221351 scopus 로고    scopus 로고
    • Pipe system diagnosis and leak detection by unsteady-state tests.2: Wavelet analysis
    • Ferrante, M., and Brunone, B. (2003b). "Pipe system diagnosis and leak detection by unsteady-state tests. 2: Wavelet analysis." Adv. Water Resour., 26(1), 107-116.
    • (2003) Adv. Water Resour. , vol.26 , Issue.1 , pp. 107-116
    • Ferrante, M.1    Brunone, B.2
  • 14
    • 36448970548 scopus 로고    scopus 로고
    • Wavelets for the analysis of transient pressure signals for leak detection
    • Ferrante, M., Brunone, B., and Meniconi, S. (2007). "Wavelets for the analysis of transient pressure signals for leak detection." J. Hydraul. Eng., 133(11), 1274-1282.
    • (2007) J. Hydraul. Eng. , vol.133 , Issue.11 , pp. 1274-1282
    • Ferrante, M.1    Brunone, B.2    Meniconi, S.3
  • 15
    • 77149129884 scopus 로고    scopus 로고
    • Leak detection in branched pipe systems coupling wavelet analysis and a lagrangian model
    • Ferrante, M., Brunone, B., and Meniconi, S. (2009a). "Leak detection in branched pipe systems coupling wavelet analysis and a lagrangian model." J. Water Supply Res. Technol., 58(2), 95-106.
    • (2009) J. Water Supply Res. Technol. , vol.58 , Issue.2 , pp. 95-106
    • Ferrante, M.1    Brunone, B.2    Meniconi, S.3
  • 18
    • 33750564300 scopus 로고    scopus 로고
    • Experimental verification of the frequency response method for pipeline leak detection
    • Lee, P. J., Lambert, M. F., Simpson, A. R., Vítkovský, J. P., and Liggett, J. (2006). "Experimental verification of the frequency response method for pipeline leak detection." J. Hydraul. Res., 44(5), 693-707.
    • (2006) J. Hydraul. Res. , vol.44 , Issue.5 , pp. 693-707
    • Lee, P.J.1    Lambert, M.F.2    Simpson, A.R.3    Vítkovský, J.P.4    Liggett, J.5
  • 19
    • 77957141096 scopus 로고    scopus 로고
    • Quantifying linearization error when modeling fluid pipeline transients using the frequency response method
    • Lee, P. J., and Vítkovský, J. P. (2010). "Quantifying linearization error when modeling fluid pipeline transients using the frequency response method." J. Hydraul. Eng., 136(10), 831-836.
    • (2010) J. Hydraul. Eng. , vol.136 , Issue.10 , pp. 831-836
    • Lee, P.J.1    Vítkovský, J.P.2
  • 20
    • 42449085881 scopus 로고    scopus 로고
    • Discrete blockage detection in pipelines using the frequency response diagram: Numerical study
    • Lee, P. J., Vítkovský, J. P., Lambert, M. F., Simpson, A. R., and Liggett, J. (2008). "Discrete blockage detection in pipelines using the frequency response diagram: Numerical study." J. Hydraul. Eng., 134(5), 658-663.
    • (2008) J. Hydraul. Eng. , vol.134 , Issue.5 , pp. 658-663
    • Lee, P.J.1    Vítkovský, J.P.2    Lambert, M.F.3    Simpson, A.R.4    Liggett, J.5
  • 21
    • 79960136989 scopus 로고    scopus 로고
    • In-line pipe device checking by short period analysis of transient tests
    • Meniconi, S., Brunone, B., and Ferrante, M. (2011a). "In-line pipe device checking by short period analysis of transient tests." J. Hydraul. Eng., 137(7), 713-722.
    • (2011) J. Hydraul. Eng. , vol.137 , Issue.7 , pp. 713-722
    • Meniconi, S.1    Brunone, B.2    Ferrante, M.3
  • 22
    • 84863433040 scopus 로고    scopus 로고
    • Transient hydrodynamics of in-line valves in viscoelastic pressurized pipes. Long period analysis
    • Meniconi, S., Brunone, B., and Ferrante, M. (2012a). "Transient hydrodynamics of in-line valves in viscoelastic pressurized pipes. Long period analysis." Exp. Fluids, 53(1), 265-275.
    • (2012) Exp. Fluids , vol.53 , Issue.1 , pp. 265-275
    • Meniconi, S.1    Brunone, B.2    Ferrante, M.3
  • 23
    • 84864095471 scopus 로고    scopus 로고
    • Water hammer pressure waves interaction at cross-section changes in series in viscoelastic pipes
    • Meniconi, S., Brunone, B., and Ferrante, M. (2012b). "Water hammer pressure waves interaction at cross-section changes in series in viscoelastic pipes." J. Fluids Struct., 33(1), 44-58.
    • (2012) J. Fluids Struct. , vol.33 , Issue.1 , pp. 44-58
    • Meniconi, S.1    Brunone, B.2    Ferrante, M.3
  • 24
    • 78650306359 scopus 로고    scopus 로고
    • Small amplitude sharp pressure waves to diagnose pipe systems
    • Meniconi, S., Brunone, B., Ferrante, M., and Massari, C. (2011b). "Small amplitude sharp pressure waves to diagnose pipe systems." Water Resour. Manage., 25(1), 79-96.
    • (2011) Water Resour. Manage. , vol.25 , Issue.1 , pp. 79-96
    • Meniconi, S.1    Brunone, B.2    Ferrante, M.3    Massari, C.4
  • 25
    • 31044450969 scopus 로고    scopus 로고
    • Detection of partial blockage in single pipelines
    • Mohapatra, P. K., Chaudhry, M. H., Kassem, A. A., and Moloo, J. (2006). "Detection of partial blockage in single pipelines." J. Hydraul. Eng., 132(2), 200-206.
    • (2006) J. Hydraul. Eng. , vol.132 , Issue.2 , pp. 200-206
    • Mohapatra, P.K.1    Chaudhry, M.H.2    Kassem, A.A.3    Moloo, J.4
  • 26
    • 37549046012 scopus 로고    scopus 로고
    • Partial blockage detection in pipelines by frequency response method
    • Sattar, A. M., Chaudhry, M. H., and Kassem, A. A. (2008). "Partial blockage detection in pipelines by frequency response method." J. Hydraul. Eng., 134(1), 76-89.
    • (2008) J. Hydraul. Eng. , vol.134 , Issue.1 , pp. 76-89
    • Sattar, A.M.1    Chaudhry, M.H.2    Kassem, A.A.3
  • 27
    • 69949087867 scopus 로고    scopus 로고
    • Transient response analysis for fault detection and pipeline wall condition assessment in field water transmission and distribution pipelines and networks
    • Ph. D. thesis, Univ. of Adelaide, SA, Australia
    • Stephens, M. L. (2008). "Transient response analysis for fault detection and pipeline wall condition assessment in field water transmission and distribution pipelines and networks." Ph. D. thesis, Univ. of Adelaide, SA, Australia.
    • (2008)
    • Stephens, M.L.1
  • 28
    • 0003671716 scopus 로고
    • ressure surges in pipe and duct systems
    • Ashgate Publishing Group, UK
    • Swaffield, J. A., and Boldy, A. P. (1993). Pressure surges in pipe and duct systems, Ashgate Publishing Group, UK.
    • (1993)
    • Swaffield, J.A.1    Boldy, A.P.2
  • 29
    • 0002237943 scopus 로고    scopus 로고
    • On turbulent, unsteady, smoothpipe friction
    • 7th Int. Conf. Pressure Surges and Fluid Transients in Pipelines and Open Channels, BHR Group, Harrogate, UK
    • Vardy, A. E., and Brown, J. M. B. (1996). "On turbulent, unsteady, smoothpipe friction." 7th Int. Conf. Pressure Surges and Fluid Transients in Pipelines and Open Channels, BHR Group, Harrogate, UK, 289-311.
    • (1996) , pp. 289-311
    • Vardy, A.E.1    Brown, J.M.B.2
  • 30
    • 19044377093 scopus 로고    scopus 로고
    • Detection and location of a partial blockage in a pipeline using damping of fluid transients
    • Wang, X. J., Lambert, M. F., and Simpson, A. R. (2005). "Detection and location of a partial blockage in a pipeline using damping of fluid transients." J. Water Resour. Plann. Manage., 131(3), 244-249.
    • (2005) J. Water Resour. Plann. Manage. , vol.131 , Issue.3 , pp. 244-249
    • Wang, X.J.1    Lambert, M.F.2    Simpson, A.R.3
  • 31
    • 0036642343 scopus 로고    scopus 로고
    • Leak detection in pipeline systems using the damping of fluid transients
    • Wang, X. J., Lambert, M. F., Simpson, A. R., Liggett, J. A., and Vítkovský, J. P. (2002). "Leak detection in pipeline systems using the damping of fluid transients." J. Hydraul. Eng., 128(7), 697-711.
    • (2002) J. Hydraul. Eng. , vol.128 , Issue.7 , pp. 697-711
    • Wang, X.J.1    Lambert, M.F.2    Simpson, A.R.3    Liggett, J.A.4    Vítkovský, J.P.5
  • 33
    • 85024578678 scopus 로고
    • Frequency-dependent friction in transient pipe flow
    • Zielke, W. (1968). "Frequency-dependent friction in transient pipe flow." J. Basic Eng., 90(1), 109-115.
    • (1968) J. Basic Eng. , vol.90 , Issue.1 , pp. 109-115
    • Zielke, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.