메뉴 건너뛰기




Volumn 73, Issue 6, 2013, Pages 466-475

One-sample determination of glomerular filtration rate (GFR) in children. An evaluation based on 75 consecutive patients

Author keywords

51Cr EDTA; Glomerular filtration rate; Plasma clearance; Renal function; Slope intercept technique

Indexed keywords

EDETATE CHROMIUM CR 51;

EID: 84884225924     PISSN: 00365513     EISSN: 15027686     Source Type: Journal    
DOI: 10.3109/00365513.2013.803233     Document Type: Article
Times cited : (3)

References (23)
  • 2
    • 63649084825 scopus 로고    scopus 로고
    • Measuring glomerular fi ltration rate in children; Can cystatin C replace established methods? A review
    • Andersen TB , Eskild-Jensen A , Fr k i r J , Brchner- Mortensen J . Measuring glomerular fi ltration rate in children; can cystatin C replace established methods? A review. Pediatr Nephrol 2009 ; 24 : 929-41 .
    • (2009) Pediatr Nephrol , vol.24 , pp. 929-941
    • Andersen, T.B.1    Eskild-Jensen, A.2    Frkir, J.3    Brchner-Mortensen, J.4
  • 3
    • 0014527230 scopus 로고
    • Renal inulin clearance versus total plasma clearance of 51 Cr-EDTA
    • Brchner-Mortensen J, Giese J, Rossing N . R enal inulin clearance versus total plasma clearance of 51 Cr-EDTA . Scand J Clin Lab Invest 1969 ; 23 : 301-5 .
    • (1969) Scand J Clin Lab Invest , vol.23 , pp. 301-305
    • Brchner-Mortensen, J.1    Giese, J.2    Rossing, N.3
  • 5
    • 0016052419 scopus 로고
    • A simple method for accurate assessment of the glomerular fi ltration rate in children
    • Brchner-Mortensen J, Haahr J, Chistoffersen J . A simple method for accurate assessment of the glomerular fi ltration rate in children . Scan J Clin Lab Invest 1974 ; 33 : 140-3 .
    • (1974) Scan J Clin Lab Invest , vol.33 , pp. 140-143
    • Brchner-Mortensen, J.1    Haahr, J.2    Chistoffersen, J.3
  • 6
    • 0021288699 scopus 로고
    • 51Cr-EDTA clearance determined by one plasma sample in children
    • Groth S, Aasted M . 5 1 Cr-EDTA clearance determined by one plasma sample in children . Clin Physiol 1984 ; 4 : 75-83 . (Pubitemid 14196135)
    • (1984) Clinical Physiology , vol.4 , Issue.1 , pp. 75-83
    • Groth, S.1    Aasted, M.2
  • 7
    • 84884275592 scopus 로고
    • Determination of 51 Cr-EDTA clearance in infants by a single capillary blood sample
    • Fjeldborg P . Brchner-Mortensen J . D etermination of 51 Cr-EDTA clearance in infants by a single capillary blood sample . Scand J Clin Lab Invest 1986 ; 112 : 541-6 .
    • (1986) Scand J Clin Lab Invest , vol.112 , pp. 541-546
    • Fjeldborg, P.1    Brchner-Mortensen, J.2
  • 8
    • 0035079412 scopus 로고    scopus 로고
    • Guidelines for glomerular fi ltration rate determination in children
    • Paediatric Committee of the european association of nuclear medicine
    • Piepsz A , Colarinha P , Gordon I , Hahn K, Olivier P , Sixt R , van Velzen J . Paediatric Committee of the European Association of Nuclear Medicine. Guidelines for glomerular fi ltration rate determination in children . Eur J Nucl Med 2001 ; 28 : 31-6 .
    • (2001) Eur J Nucl Med , vol.28 , pp. 31-36
    • Piepsz, A.1    Colarinha, P.2    Gordon, I.3    Hahn, K.4    Olivier, P.5    Sixt, R.6    Van Velzen, J.7
  • 9
    • 67649784548 scopus 로고    scopus 로고
    • Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance
    • Jdal L , Brchner-Mortensen J . R eassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: analytically correct relationship between total and one-pool clearance . Scand J Clin Lab Invest 2009 ; 69 : 305-13 .
    • (2009) Scand J Clin Lab Invest , vol.69 , pp. 305-313
    • Jdal, L.1    Brchner-Mortensen, J.2
  • 10
    • 67649718403 scopus 로고    scopus 로고
    • Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part II: Empirically determined relationships between total and onepool clearance
    • Brchner-Mortensen J , Jdal L . Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part II: empirically determined relationships between total and onepool clearance . Scand J Clin Lab Invest 2009 : 69 : 314-22 .
    • (2009) Scand J Clin Lab Invest , vol.69 , pp. 314-322
    • Brchner-Mortensen, J.1    Jdal, L.2
  • 11
    • 0019306511 scopus 로고
    • A simple injection method for determination of the extracellular fl uid volume
    • Brchner-Mortensen J . A simple injection method for determination of the extracellular fl uid volume . Scand J Clin Lab Invest 1980 ; 40 : 567-73 .
    • (1980) Scand J Clin Lab Invest , vol.40 , pp. 567-573
    • Brchner-Mortensen, J.1
  • 12
    • 0017864678 scopus 로고
    • Geometric method for measuring body surface area: A height-weight formula validated in infants, children, and adults
    • Haycock BG , Schwartz GJ , Wisotsky DH . G eometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults . J Pediatr 1978 ; 93 : 62-6 . (Pubitemid 8351870)
    • (1978) Journal of Pediatrics , vol.93 , Issue.1 , pp. 62-66
    • Haycock, G.B.1    Schwartz, G.J.2    Wisotsky, D.H.3
  • 13
    • 0025887186 scopus 로고
    • Estimation of glomerular fi ltration rate in infants and in children using a single-plasma sample method
    • Ham HR , Piepsz A . E stimation of glomerular fi ltration rate in infants and in children using a single-plasma sample method . J Nucl Med 1991 ; 32 : 1294-7 .
    • (1991) J Nucl Med , vol.32 , pp. 1294-1297
    • Ham, H.R.1    Piepsz, A.2
  • 14
    • 0026507526 scopus 로고
    • Limitations of clearance determination using the single sample distribution volume method
    • Kotzerke J , Burchert W , Wiese H , Smekal UV , Hundeshagen H . Limitations of clearance determination using the single sample distribution volume method . Eur J Nucl Med 1992 ; 19 : 19-24 .
    • (1992) Eur J Nucl Med , vol.19 , pp. 19-24
    • Kotzerke, J.1    Burchert, W.2    Wiese, H.3    Smekal, U.V.4    Hundeshagen, H.5
  • 15
    • 0028003494 scopus 로고
    • E stimation of normal chromium-51 ethylene diamine tetra-acetic acid clearance in children
    • Piepsz A , Pintelon H, Ham HR . E stimation of normal chromium-51 ethylene diamine tetra-acetic acid clearance in children . Eur J Nucl Med 1994 ; 21 : 12-26 .
    • (1994) Eur J Nucl Med , vol.21 , pp. 12-26
    • Piepsz, A.1    Pintelon, H.2    Ham, H.R.3
  • 16
    • 0030640438 scopus 로고    scopus 로고
    • E valuation of single sample clearance calculations in 902 patients
    • Lundqvist S , Hietala S -O, Groth S , Sj d in J -G . E valuation of single sample clearance calculations in 902 patients . Acta Radiol 1997 ; 38 : 68-72 .
    • (1997) Acta Radiol , vol.38 , pp. 68-72
    • Lundqvist, S.1    Hietala, S.-O.2    Groth, S.3    Sjdin, J.-G.4
  • 17
    • 0034252585 scopus 로고    scopus 로고
    • Influence of time interval and number of blood samples on the error in renal clearance determination using a monoexponential model: A Monte Carlo simulation
    • Van Laere K, Georges B, Peipsz A , Ham HR . Infl uence of time interval and number of blood samples on the error in renal clearance determination using a monoexponential model: a Monte Carlo simulation . Nucl Med Commun 2000 ; 21 : 741-5 .
    • (2000) Nucl Med Commun , vol.21 , pp. 741-745
    • Van Laere, K.1    Georges, B.2    Peipsz, A.3    Ham, H.R.4
  • 18
    • 0035073956 scopus 로고    scopus 로고
    • Influence of errors in sampling time and in activity measurement on the single sample clearance determination
    • DOI 10.1097/00006231-200104000-00012
    • De Sadeleer C , Peipsz A , Ham H R . Influence of errors in sampling time and in activity measurement on the single sample clearance determination . Nucl Med Commun 2001 ; 22 : 429-32 . (Pubitemid 32291659)
    • (2001) Nuclear Medicine Communications , vol.22 , Issue.4 , pp. 429-432
    • De Sadeleer, C.1    Piepsz, A.2    Ham, H.R.3
  • 20
    • 2142662189 scopus 로고    scopus 로고
    • 51Cr-EDTA clearance
    • DOI 10.1097/00006231-200404000-00013
    • Bird NJ , Henderson BL, Lui D , Peters M . T ime to complete mixing for the measurement of glomerular fi ltration rate from single bolus plasma 51Cr-EDTA clearance . Nucl Med Commun 2004 ; 25 : 393-8 . (Pubitemid 38553361)
    • (2004) Nuclear Medicine Communications , vol.25 , Issue.4 , pp. 393-398
    • Bird, N.J.1    Henderson, B.L.2    Lui, D.3    Peters, M.4
  • 21
    • 27344456641 scopus 로고    scopus 로고
    • 51Cr-EDTA measurements of glomerular filtration rate in children
    • DOI 10.1097/01.mnm.0000179294.16339.4a
    • Blake GM , Gardiner N , Gnanasegaran G , Dizdarevic S . Reference ranges for 51Cr-EDTA measurements of glomerular fi ltration rate in children . Nucl Med Commun 2005 ; 26 : 983-7 . (Pubitemid 41527288)
    • (2005) Nuclear Medicine Communications , vol.26 , Issue.11 , pp. 983-987
    • Blake, G.M.1    Gardiner, N.2    Gnanasegaran, G.3    Dizdarevic, S.4
  • 23
    • 0022359548 scopus 로고
    • W hole-body microvascular permeability of small molecules in man: Clinical aspects, basic concepts and limitation of the single injection technique
    • Thenriksen J H . W hole-body microvascular permeability of small molecules in man: clinical aspects, basic concepts and limitation of the single injection technique . Scand J Clin Lab Invest 1985 ; 45 : 509-13 .
    • (1985) Scand J Clin Lab Invest , vol.45 , pp. 509-513
    • Thenriksen, J.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.