-
2
-
-
79960049457
-
Development of a highly sensitive fluorescence probe for hydrogen peroxide
-
Abo M, Urano Y, Hanaoka K, Terai T, Komatsu T, Nagano T (2011) Development of a highly sensitive fluorescence probe for hydrogen peroxide. J Am Chem Soc 133: 10629-10637.
-
(2011)
J Am Chem Soc
, vol.133
, pp. 10629-10637
-
-
Abo, M.1
Urano, Y.2
Hanaoka, K.3
Terai, T.4
Komatsu, T.5
Nagano, T.6
-
3
-
-
79955010718
-
Luminescent probes for detection and imaging of hydrogen peroxide
-
Schäferling M, Grögel DBM, Schreml S (2011) Luminescent probes for detection and imaging of hydrogen peroxide. Microchim Acta 174: 1-18.
-
(2011)
Microchim Acta
, vol.174
, pp. 1-18
-
-
Schäferling, M.1
Grögel, D.B.M.2
Schreml, S.3
-
4
-
-
43949099273
-
Electrochemiluminescent detection of hydrogen peroxide using amphiphilic luminol derivatives in solution
-
Jiao T, Leca-Bouvier BD, Boullanger P, Blum LJ, Girard-Egrot AP (2008) Electrochemiluminescent detection of hydrogen peroxide using amphiphilic luminol derivatives in solution. Colloids Surf A 321: 143-146.
-
(2008)
Colloids Surf A
, vol.321
, pp. 143-146
-
-
Jiao, T.1
Leca-Bouvier, B.D.2
Boullanger, P.3
Blum, L.J.4
Girard-Egrot, A.P.5
-
5
-
-
0037170699
-
Determination of hydrogen peroxide by using a flow injection system with immobilized peroxidase and long pathlength capillary spectrophotometry
-
Pappas AC, Stalikas CD, Fiamegos YC, Karayannis MI (2002) Determination of hydrogen peroxide by using a flow injection system with immobilized peroxidase and long pathlength capillary spectrophotometry. Anal Chim Acta 455: 305-313.
-
(2002)
Anal Chim Acta
, vol.455
, pp. 305-313
-
-
Pappas, A.C.1
Stalikas, C.D.2
Fiamegos, Y.C.3
Karayannis, M.I.4
-
6
-
-
84870786879
-
An amperometric biosensor for the detection of hydrogen peroxide released from human breast cancer cells
-
Zhao J, Yan YL, Zhu L, Li XX, Li GX (2013) An amperometric biosensor for the detection of hydrogen peroxide released from human breast cancer cells. Biosens Bioelectron 41: 815-819.
-
(2013)
Biosens Bioelectron
, vol.41
, pp. 815-819
-
-
Zhao, J.1
Yan, Y.L.2
Zhu, L.3
Li, X.X.4
Li, G.X.5
-
7
-
-
29944443113
-
Electrochemical non-enzymatic glucose sensors
-
Park S, Boo H, Chung TD (2006) Electrochemical non-enzymatic glucose sensors. Anal Chim Acta 556: 46-57.
-
(2006)
Anal Chim Acta
, vol.556
, pp. 46-57
-
-
Park, S.1
Boo, H.2
Chung, T.D.3
-
8
-
-
84872042119
-
Electrochemical sensing of hydrogen peroxide using metal nanoparticles: a review
-
Chen SH, Yuan R, Chai YQ, Hu FX (2013) Electrochemical sensing of hydrogen peroxide using metal nanoparticles: a review. Microchim Acta 180: 15-32.
-
(2013)
Microchim Acta
, vol.180
, pp. 15-32
-
-
Chen, S.H.1
Yuan, R.2
Chai, Y.Q.3
Hu, F.X.4
-
9
-
-
79953659327
-
Direct electrochemistry of myoglobin based on electrodeposition of Pd nanoparticles with carbon ionic liquid electrode as basic electrode
-
Huang J, Zheng J, Sheng Q (2011) Direct electrochemistry of myoglobin based on electrodeposition of Pd nanoparticles with carbon ionic liquid electrode as basic electrode. Microchim Acta 173: 157-163.
-
(2011)
Microchim Acta
, vol.173
, pp. 157-163
-
-
Huang, J.1
Zheng, J.2
Sheng, Q.3
-
10
-
-
79960424986
-
Preparation, characterization, surface modification and redox reactions of silver nanoparticles in the presence of tryptophan
-
Jacob JA, Naumov S, Mukherjee T, Kapoor S (2011) Preparation, characterization, surface modification and redox reactions of silver nanoparticles in the presence of tryptophan. Colloids Surf B 87: 498-504.
-
(2011)
Colloids Surf B
, vol.87
, pp. 498-504
-
-
Jacob, J.A.1
Naumov, S.2
Mukherjee, T.3
Kapoor, S.4
-
11
-
-
84873716323
-
The selective oxidation of 1,2-propanediol to lactic acid using mild conditions and gold-based nanoparticulate catalysts
-
Ryabenkova YL, He Q, Miedziak PJ, Dummer NF, Taylor SH, Carley AF, Morgan DJ, Dimitratos N, Willock DJ, Bethell D, Knight DW, Chadwick D, Kiely CJ, Hutchings GJ (2013) The selective oxidation of 1, 2-propanediol to lactic acid using mild conditions and gold-based nanoparticulate catalysts. Catal Today 203: 139-145.
-
(2013)
Catal Today
, vol.203
, pp. 139-145
-
-
Ryabenkova, Y.L.1
He, Q.2
Miedziak, P.J.3
Dummer, N.F.4
Taylor, S.H.5
Carley, A.F.6
Morgan, D.J.7
Dimitratos, N.8
Willock, D.J.9
Bethell, D.10
Knight, D.W.11
Chadwick, D.12
Kiely, C.J.13
Hutchings, G.J.14
-
12
-
-
84873342309
-
Electrochemical deposition of mesoporous Pt-Au alloy films in aqueous surfactant solutions: towards a highly sensitive amperometric glucose sensor
-
Li CL, Wang HJ, Yamauchi Y (2013) Electrochemical deposition of mesoporous Pt-Au alloy films in aqueous surfactant solutions: towards a highly sensitive amperometric glucose sensor. Chem Eur J 19: 2242-2246.
-
(2013)
Chem Eur J
, vol.19
, pp. 2242-2246
-
-
Li, C.L.1
Wang, H.J.2
Yamauchi, Y.3
-
13
-
-
84884206106
-
Platinum nanostructures via self-assembly of an amyloid-like peptide: a novel electrocatalyst for the oxygen reduction
-
Zhou BB, Sun ZF, Li D, Zhang T, Deng L, Liu YN (2013) Platinum nanostructures via self-assembly of an amyloid-like peptide: a novel electrocatalyst for the oxygen reduction. Nanoscale 5: 2669-2673.
-
(2013)
Nanoscale
, vol.5
, pp. 2669-2673
-
-
Zhou, B.B.1
Sun, Z.F.2
Li, D.3
Zhang, T.4
Deng, L.5
Liu, Y.N.6
-
15
-
-
77956424251
-
Direct electrocatalytic reduction of hydrogen peroxide at a glassy carbon electrode modified with polypyrrole nanowires and platinum hollow nanospheres
-
Li JJ, Yuan R, Chai YQ, Zhang TT, Che X (2010) Direct electrocatalytic reduction of hydrogen peroxide at a glassy carbon electrode modified with polypyrrole nanowires and platinum hollow nanospheres. Microchim Acta 171: 125-131.
-
(2010)
Microchim Acta
, vol.171
, pp. 125-131
-
-
Li, J.J.1
Yuan, R.2
Chai, Y.Q.3
Zhang, T.T.4
Che, X.5
-
16
-
-
84860307166
-
A non-enzymatic hydrogen peroxide sensor based on poly(vinyl alcohol)-multiwalled carbon nanotubes-platinum nanoparticles hybrids modified glassy carbon electrode
-
Fang YX, Zhang D, Qin X, Miao ZY, Takahashi S, Anzai J, Chen Q (2012) A non-enzymatic hydrogen peroxide sensor based on poly(vinyl alcohol)-multiwalled carbon nanotubes-platinum nanoparticles hybrids modified glassy carbon electrode. Electrochim Acta 70: 266-271.
-
(2012)
Electrochim Acta
, vol.70
, pp. 266-271
-
-
Fang, Y.X.1
Zhang, D.2
Qin, X.3
Miao, Z.Y.4
Takahashi, S.5
Anzai, J.6
Chen, Q.7
-
17
-
-
84874053495
-
PVP stabilized Pt nano particles catalyzed de-oxygenation of phenoxazine group by hydrazine in physiological buffer media: surfactant competes with reactants for the same surface sites
-
Das RS, Singh B, Banerjee R, Mukhopadhyay S (2013) PVP stabilized Pt nano particles catalyzed de-oxygenation of phenoxazine group by hydrazine in physiological buffer media: surfactant competes with reactants for the same surface sites. Dalton Trans 42: 4068-4080.
-
(2013)
Dalton Trans
, vol.42
, pp. 4068-4080
-
-
Das, R.S.1
Singh, B.2
Banerjee, R.3
Mukhopadhyay, S.4
-
18
-
-
77949310151
-
Fabrication of Pt/polypyrrole hybrid hollow microspheres and their application in electrochemical biosensing towards hydrogen peroxide
-
Bian XJ, Lu XF, Jin E, Kong LR, Zhang WJ, Wang C (2010) Fabrication of Pt/polypyrrole hybrid hollow microspheres and their application in electrochemical biosensing towards hydrogen peroxide. Talanta 81: 813-818.
-
(2010)
Talanta
, vol.81
, pp. 813-818
-
-
Bian, X.J.1
Lu, X.F.2
Jin, E.3
Kong, L.R.4
Zhang, W.J.5
Wang, C.6
-
19
-
-
77955523549
-
Platinum nanoparticle ensemble-on-graphene hybrid nanosheet: one-pot, rapid synthesis, and used as new electrode material for electrochemical sensing
-
Guo S, Wen D, Zhai Y, Dong S, Wang E (2010) Platinum nanoparticle ensemble-on-graphene hybrid nanosheet: one-pot, rapid synthesis, and used as new electrode material for electrochemical sensing. ACS Nano 4: 3959-3968.
-
(2010)
ACS Nano
, vol.4
, pp. 3959-3968
-
-
Guo, S.1
Wen, D.2
Zhai, Y.3
Dong, S.4
Wang, E.5
-
20
-
-
84866110906
-
Nanocomposites of palladium nanoparticle-loaded mesoporous carbon nanospheres for the electrochemical determination of hydrogen peroxide
-
Bian XJ, Guo K, Liao L, Xiao JJ, Kong JL, Ji C, Liu BH (2012) Nanocomposites of palladium nanoparticle-loaded mesoporous carbon nanospheres for the electrochemical determination of hydrogen peroxide. Talanta 99: 256-261.
-
(2012)
Talanta
, vol.99
, pp. 256-261
-
-
Bian, X.J.1
Guo, K.2
Liao, L.3
Xiao, J.J.4
Kong, J.L.5
Ji, C.6
Liu, B.H.7
-
21
-
-
67149139594
-
Functionalization of electrospun ceramic nanofibre membranes with noble-metal nanostructures for catalytic applications
-
Formo E, Yavuz MS, Lee EP, Lane L, Xia YN (2009) Functionalization of electrospun ceramic nanofibre membranes with noble-metal nanostructures for catalytic applications. J Mater Chem 19: 3878-3882.
-
(2009)
J Mater Chem
, vol.19
, pp. 3878-3882
-
-
Formo, E.1
Yavuz, M.S.2
Lee, E.P.3
Lane, L.4
Xia, Y.N.5
-
22
-
-
84866390916
-
2 hollow fibers
-
2 hollow fibers. Angew Chem Int Ed 51: 9543-9546.
-
(2012)
Angew Chem Int Ed
, vol.51
, pp. 9543-9546
-
-
Yoon, K.1
Yang, Y.2
Lu, P.3
Wan, D.H.4
Peng, H.C.5
Masias, K.S.6
Fanson, P.T.7
Campbell, C.T.8
Xia, Y.N.9
-
24
-
-
40449134185
-
Electrospun palladium nanoparticle loaded carbon nanofibers and their electrocatalytic activities towards hydrogen peroxide and NADH
-
Huang JS, Wang DW, Hou HQ, You TY (2008) Electrospun palladium nanoparticle loaded carbon nanofibers and their electrocatalytic activities towards hydrogen peroxide and NADH. Adv Funct Mater 18: 441-448.
-
(2008)
Adv Funct Mater
, vol.18
, pp. 441-448
-
-
Huang, J.S.1
Wang, D.W.2
Hou, H.Q.3
You, T.Y.4
-
25
-
-
77958615221
-
Facile synthesis of a platinum nanoflower monolayer on a single-walled carbon nanotube membrane and its application in glucose detection
-
Su L, Jia W, Zhang L, Beacham C, Zhang H, Lei Y (2010) Facile synthesis of a platinum nanoflower monolayer on a single-walled carbon nanotube membrane and its application in glucose detection. J Phys Chem C 114: 18121-18125.
-
(2010)
J Phys Chem C
, vol.114
, pp. 18121-18125
-
-
Su, L.1
Jia, W.2
Zhang, L.3
Beacham, C.4
Zhang, H.5
Lei, Y.6
-
26
-
-
79960906631
-
Cobalt oxide acicular nanorods with high sensitivity for the non-enzymatic detection of glucose
-
Kung CW, Lin CY, Lai YH, Vittal R, Ho KC (2011) Cobalt oxide acicular nanorods with high sensitivity for the non-enzymatic detection of glucose. Biosens Bioelectron 27: 125-131.
-
(2011)
Biosens Bioelectron
, vol.27
, pp. 125-131
-
-
Kung, C.W.1
Lin, C.Y.2
Lai, Y.H.3
Vittal, R.4
Ho, K.C.5
-
27
-
-
34250666192
-
Electrospinning of carbon/CdS coaxial nanofibers with photoluminescence and conductive properties
-
Yang Y, Wang HY, Lu XF, Zhao YY, Li X, Wang C (2007) Electrospinning of carbon/CdS coaxial nanofibers with photoluminescence and conductive properties. Mater Sci Eng B 140: 48-52.
-
(2007)
Mater Sci Eng B
, vol.140
, pp. 48-52
-
-
Yang, Y.1
Wang, H.Y.2
Lu, X.F.3
Zhao, Y.Y.4
Li, X.5
Wang, C.6
-
28
-
-
77949296206
-
Synthesis and electrocatalysis of carbon nanofiber-supported platinum by 1-AP functionalization and polyol processing technique
-
Lin Z, Ji L, Woodroof MD, Yao YF, Krause W, Zhang X (2010) Synthesis and electrocatalysis of carbon nanofiber-supported platinum by 1-AP functionalization and polyol processing technique. J Phys Chem C 114: 3791-3797.
-
(2010)
J Phys Chem C
, vol.114
, pp. 3791-3797
-
-
Lin, Z.1
Ji, L.2
Woodroof, M.D.3
Yao, Y.F.4
Krause, W.5
Zhang, X.6
-
30
-
-
70449555202
-
Polyacrylonitrile-derived 1D carbon structures via template wetting and electrospinning
-
Khanderi J, Schneider JJ (2009) Polyacrylonitrile-derived 1D carbon structures via template wetting and electrospinning. Z Anorg Allg Chem 635: 2135-2142.
-
(2009)
Z Anorg Allg Chem
, vol.635
, pp. 2135-2142
-
-
Khanderi, J.1
Schneider, J.J.2
-
31
-
-
84856288231
-
Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
-
Zhong HA, Yuan R, Chai YQ, Zhang Y, Wang CY, Jia F (2012) Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles. Microchim Acta 176: 389-395.
-
(2012)
Microchim Acta
, vol.176
, pp. 389-395
-
-
Zhong, H.A.1
Yuan, R.2
Chai, Y.Q.3
Zhang, Y.4
Wang, C.Y.5
Jia, F.6
-
32
-
-
77955424330
-
Poly(BCB)/Au-nanoparticles hybrid film modified electrode: preparation, characterization and its application as a non-enzymatic sensor
-
Kumar SA, Wang SF, Chang YT (2010) Poly(BCB)/Au-nanoparticles hybrid film modified electrode: preparation, characterization and its application as a non-enzymatic sensor. Thin Solid Films 518: 5832-5838.
-
(2010)
Thin Solid Films
, vol.518
, pp. 5832-5838
-
-
Kumar, S.A.1
Wang, S.F.2
Chang, Y.T.3
-
33
-
-
77956936474
-
2 biosensor and simultaneous determination for AA, DA, and UA by MWCNT-PEDOT film
-
2 biosensor and simultaneous determination for AA, DA, and UA by MWCNT-PEDOT film. Biosens Bioelectron 26: 608-614.
-
(2010)
Biosens Bioelectron
, vol.26
, pp. 608-614
-
-
Lin, K.C.1
Tsai, T.H.2
Chen, S.M.3
-
34
-
-
80053115171
-
Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
-
Wang AJ, Zhang PP, Li YF, Feng JJ, Dong WJ, Liu XY (2011) Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods. Microchim Acta 175: 31-37.
-
(2011)
Microchim Acta
, vol.175
, pp. 31-37
-
-
Wang, A.J.1
Zhang, P.P.2
Li, Y.F.3
Feng, J.J.4
Dong, W.J.5
Liu, X.Y.6
-
35
-
-
84870288969
-
Amperometric detection of hydrogen peroxide utilizing synergistic action of cobalt hexacyanoferrate and carbon nanotubes chemically modified with platinum nanoparticles
-
Han LJ, Wang Q, Tricard S, Liu JX, Fang J, Zhao JH, Shen WG (2013) Amperometric detection of hydrogen peroxide utilizing synergistic action of cobalt hexacyanoferrate and carbon nanotubes chemically modified with platinum nanoparticles. RSC Adv 3: 281-287.
-
(2013)
RSC Adv
, vol.3
, pp. 281-287
-
-
Han, L.J.1
Wang, Q.2
Tricard, S.3
Liu, J.X.4
Fang, J.5
Zhao, J.H.6
Shen, W.G.7
|