-
1
-
-
0033511955
-
Dodick photolysis for cataract surgery: Early experience with the Q-switched neodynium: YAG Laser in 100 consecutive patients
-
Nov
-
Kanellopoulos AJ, Dodick J, Froman, Brauweiler, Alzner E. Dodick photolysis for cataract surgery: early experience with the Q-switched neodynium: YAG Laser in 100 consecutive patients. Ophthalmology. Nov 1999;106(11):2197-2202.
-
(1999)
Ophthalmology
, vol.106
, Issue.11
, pp. 2197-2202
-
-
Kanellopoulos, A.J.1
Dodick, J.2
Froman, B.3
Alzner, E.4
-
2
-
-
0035077627
-
Laser cataract surgery: A prospective evaluation of 1000 consecutive laser cataract procedures using the Dodick photolysis Nd:YAG system
-
Photolysis Investigative Group, Apr, discussion 654-655
-
Kanellopoulos AJ. Photolysis Investigative Group. Laser cataract surgery: A prospective evaluation of 1000 consecutive laser cataract procedures using the Dodick photolysis Nd:YAG system. Ophthalmology. Apr 2001;108(4): 649-654; discussion 654-655.
-
(2001)
Ophthalmology
, vol.108
, Issue.4
, pp. 649-654
-
-
Kanellopoulos, A.J.1
-
3
-
-
78649810323
-
Evaluation of phacoemulsificationinduced oxidative stress and damage of cultured human corneal endothelial cells in different solutions using redox fluorometry microscopy
-
Nishi Y, Engler C, Na DR, et al. Evaluation of phacoemulsificationinduced oxidative stress and damage of cultured human corneal endothelial cells in different solutions using redox fluorometry microscopy. Acta Ophthalmol. 2010;88(8):e323-e327.
-
(2010)
Acta Ophthalmol
, vol.88
, Issue.8
-
-
Nishi, Y.1
Engler, C.2
Na, D.R.3
-
4
-
-
78049304743
-
Comparison of endothelial changes and power settings between torsional and longitudinal phacoemulsification
-
Reuschel A, Bogatsch H, Barth T, Wiedemann R. Comparison of endothelial changes and power settings between torsional and longitudinal phacoemulsification. J Cataract Refract Surg. 2010;36(11):1855-1861.
-
(2010)
J Cataract Refract Surg
, vol.36
, Issue.11
, pp. 1855-1861
-
-
Reuschel, A.1
Bogatsch, H.2
Barth, T.3
Wiedemann, R.4
-
5
-
-
33846662618
-
Torsional mode versus conventional ultrasound mode phacoemulsification: Randomized comparative clinical study
-
Liu Y, Zeng M, Liu X, et al. Torsional mode versus conventional ultrasound mode phacoemulsification: randomized comparative clinical study. J Cataract Refract Surg. 2007;33(2):287-292.
-
(2007)
J Cataract Refract Surg
, vol.33
, Issue.2
, pp. 287-292
-
-
Liu, Y.1
Zeng, M.2
Liu, X.3
-
6
-
-
33644678962
-
Comparative clinical trial of ultrasound phacoemulsification with and without the WhiteStar system
-
Fishkind W, Bakewell B, Donnenfeld ED, Rose AD, Watkins LA, Olson RJ. Comparative clinical trial of ultrasound phacoemulsification with and without the WhiteStar system. J Cataract Refract Surg. 2006;32(1):45-49.
-
(2006)
J Cataract Refract Surg
, vol.32
, Issue.1
, pp. 45-49
-
-
Fishkind, W.1
Bakewell, B.2
Donnenfeld, E.D.3
Rose, A.D.4
Watkins, L.A.5
Olson, R.J.6
-
7
-
-
84871288835
-
Effect of femtosecond laser fragmentation on effective phacoemulsification time in cataract surgery
-
Conrad-Hengerer I, Hengerer FH, Schultz T, Dick HB. Effect of femtosecond laser fragmentation on effective phacoemulsification time in cataract surgery. J Refract Surg. 2012;28(12):879-883.
-
(2012)
J Refract Surg
, vol.28
, Issue.12
, pp. 879-883
-
-
Conrad-Hengerer, I.1
Hengerer, F.H.2
Schultz, T.3
Dick, H.B.4
-
8
-
-
85027948337
-
Effect of femtosecond laser fragmentation of the nucleus with different softening grid sizes on effective phaco time in cataract surgery
-
Conrad-Hengerer I, Hengerer FH, Schultz T, Dick HB. Effect of femtosecond laser fragmentation of the nucleus with different softening grid sizes on effective phaco time in cataract surgery. J Cataract Refract Surg. 2012;38(11):1888-1894.
-
(2012)
J Cataract Refract Surg
, vol.38
, Issue.11
, pp. 1888-1894
-
-
Conrad-Hengerer, I.1
Hengerer, F.H.2
Schultz, T.3
Dick, H.B.4
|