메뉴 건너뛰기




Volumn 14, Issue 5, 2013, Pages 13-24

Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric-modulated arc therapy (VMAT)

Author keywords

3D diode array; Patient specific QA; Setup error; VMAT

Indexed keywords

ARTICLE; COMPUTER ASSISTED RADIOTHERAPY; CONE BEAM COMPUTED TOMOGRAPHY; EQUIPMENT; EVALUATION STUDY; FEMALE; HEALTH CARE QUALITY; HUMAN; IMAGE QUALITY; INTENSITY MODULATED RADIATION THERAPY; MALE; METHODOLOGY; NEOPLASM; RADIOMETRY; RADIOTHERAPY; SEMICONDUCTOR; SENSITIVITY AND SPECIFICITY; STANDARD; STATISTICS;

EID: 84884153727     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v14i5.3828     Document Type: Article
Times cited : (20)

References (37)
  • 1
    • 37549049393 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: IMRT in a single arc
    • Otto K. Volumetric modulated arc therapy: IMRT in a single arc. Med Phys. 2008;35(1):310-17.
    • (2008) Med Phys , vol.35 , Issue.1 , pp. 310-317
    • Otto, K.1
  • 2
    • 64049093906 scopus 로고    scopus 로고
    • Volumetric intensity-modulated arc therapy vs conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study.
    • Verbakel WF, Cuijpers JP, Hoffmans D, Bieker M, Slotman BJ, Senan S. Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study. Int J Radiat Oncol Biol Phys. 2009;74(1):252-59.
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , Issue.1 , pp. 252-259
    • Verbakel, W.F.1    Cuijpers, J.P.2    Hoffmans, D.3    Bieker, M.4    Slotman, B.J.5    Senan, S.6
  • 3
    • 77956635815 scopus 로고    scopus 로고
    • Single arc volumetric modulated arc therapy of head and neck cancer
    • Bertelsen A, Hansen CR, Johansen J, Brink C. Single arc volumetric modulated arc therapy of head and neck cancer. Radiother Oncol. 2010;95(2):142-48.
    • (2010) Radiother Oncol , vol.95 , Issue.2 , pp. 142-148
    • Bertelsen, A.1    Hansen, C.R.2    Johansen, J.3    Brink, C.4
  • 4
    • 0036603788 scopus 로고    scopus 로고
    • Clinical implementation of intensity-modulated arc therapy
    • Yu C, Li X, Ma L, Chen D, et al. Clinical implementation of intensity-modulated arc therapy. Int J Radiat Oncol Biol Phys. 2002;53(2):453-63.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , Issue.2 , pp. 453-463
    • Yu, C.1    Li, X.2    Ma, L.3    Chen, D.4
  • 5
    • 34547828790 scopus 로고    scopus 로고
    • Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy
    • Cao D, Holmes T, Afghan M, Shepard D. Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy. Int J Radiat Oncol Biol Phys. 2007;69(1):240-50.
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , Issue.1 , pp. 240-250
    • Cao, D.1    Holmes, T.2    Afghan, M.3    Shepard, D.4
  • 6
    • 51049087485 scopus 로고    scopus 로고
    • Treatment of lung cancer using volumetric modulated arc therapy and image guidance: a case study
    • Bedford J, Nordmark Hansen V, McNair H, et al. Treatment of lung cancer using volumetric modulated arc therapy and image guidance: a case study. Acta Oncol. 2008;47(7):1438-43.
    • (2008) Acta Oncol , vol.47 , Issue.7 , pp. 1438-1443
    • Bedford, J.1    Nordmark Hansen, V.2    McNair, H.3
  • 7
    • 70349337606 scopus 로고    scopus 로고
    • Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs
    • Verbakel WF, Senan S, Cuijpers JP, Slotman BJ, Lagerwaard FJ. Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs. Radiother Oncol. 2009;93(1):122-24.
    • (2009) Radiother Oncol , vol.93 , Issue.1 , pp. 122-124
    • Verbakel, W.F.1    Senan, S.2    Cuijpers, J.P.3    Slotman, B.J.4    Lagerwaard, F.J.5
  • 8
    • 77954168345 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: a dosimetric and treatment efficiency analysis
    • McGrath SD, Matuszak MM, Yan D, Kestin LL, Martinez AA, Grills IS. Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: a dosimetric and treatment efficiency analysis. Radiother Oncol. 2010;95(2):153-57.
    • (2010) Radiother Oncol , vol.95 , Issue.2 , pp. 153-157
    • McGrath, S.D.1    Matuszak, M.M.2    Yan, D.3    Kestin, L.L.4    Martinez, A.A.5    Grills, I.S.6
  • 9
    • 0035924238 scopus 로고    scopus 로고
    • Optimized intensity-modulated arc therapy for prostate cancer treatment
    • Ma L, Yu C, Earl M, et al. Optimized intensity-modulated arc therapy for prostate cancer treatment. Int J Cancer. 2001;96(6):379-84.
    • (2001) Int J Cancer , vol.96 , Issue.6 , pp. 379-384
    • Ma, L.1    Yu, C.2    Earl, M.3
  • 10
    • 51849157038 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy
    • Palma D, Vollans E, James K, et al. Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys. 2008;72(4):996-1001.
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , Issue.4 , pp. 996-1001
    • Palma, D.1    Vollans, E.2    James, K.3
  • 11
    • 70350502597 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy (VMAT) vs serial tomotherapy, step-and-shoot IMRT and 3-D-conformal RT for treatment of prostate cancer.
    • Wolff D, Stieler F, Welzel G, et al. Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3-D-conformal RT for treatment of prostate cancer. Radiother Oncol. 2009;93(2):226-33.
    • (2009) Radiother Oncol , vol.93 , Issue.2 , pp. 226-233
    • Wolff, D.1    Stieler, F.2    Welzel, G.3
  • 12
    • 70350499496 scopus 로고    scopus 로고
    • Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes?
    • Guckenberger M, Richter A, Krieger T, Wilbert J, Baier K, Flentje M. Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes? Radiother Oncol. 2009;93(2):259-65.
    • (2009) Radiother Oncol , vol.93 , Issue.2 , pp. 259-265
    • Guckenberger, M.1    Richter, A.2    Krieger, T.3    Wilbert, J.4    Baier, K.5    Flentje, M.6
  • 13
    • 4744350871 scopus 로고    scopus 로고
    • Clinical implementation of intensity-modulated arc therapy (IMAT) for rectal cancer
    • Duthoy W, De Gersem W, Vergote K, et al. Clinical implementation of intensity-modulated arc therapy (IMAT) for rectal cancer. Int J Radiat Oncol Biol Phys. 2004;60(3):794-806.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , Issue.3 , pp. 794-806
    • Duthoy, W.1    De Gersem, W.2    Vergote, K.3
  • 14
    • 55149109671 scopus 로고    scopus 로고
    • A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy
    • Cozzi L, Dinshaw KA, Shrivastava SK, et al. A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol. 2008;89(2):180-91.
    • (2008) Radiother Oncol , vol.89 , Issue.2 , pp. 180-191
    • Cozzi, L.1    Dinshaw, K.A.2    Shrivastava, S.K.3
  • 15
    • 84862641791 scopus 로고    scopus 로고
    • Potential impact of volumetric modulated arc therapy on the planning and delivery of radiation therapy
    • Matuszak M, Sui H, Yan D. Potential impact of volumetric modulated arc therapy on the planning and delivery of radiation therapy. Int J Radiat Oncol Biol Phys. 2008;72(1 Suppl):S651.
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , Issue.1 SUPPL
    • Matuszak, M.1    Sui, H.2    Yan, D.3
  • 16
    • 77249094475 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: a planning study and early clinical data
    • Kuijper IT, Dahele M, Senan S, Verbakel W. Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: a planning study and early clinical data. Radiother Oncol. 2010;94(2):224-28.
    • (2010) Radiother Oncol , vol.94 , Issue.2 , pp. 224-228
    • Kuijper, I.T.1    Dahele, M.2    Senan, S.3    Verbakel, W.4
  • 17
    • 72049124537 scopus 로고    scopus 로고
    • Feasibility of single-isocenter volumetric modulated arc radiosurgery for treatment of multiple brain metastases
    • Clark GM, Popple RA, Young PE, Fiveash JB. Feasibility of single-isocenter volumetric modulated arc radiosurgery for treatment of multiple brain metastases. Int J Radiat Oncol Biol Phys. 2010;76(1):296-302.
    • (2010) Int J Radiat Oncol Biol Phys , vol.76 , Issue.1 , pp. 296-302
    • Clark, G.M.1    Popple, R.A.2    Young, P.E.3    Fiveash, J.B.4
  • 19
    • 0032798513 scopus 로고    scopus 로고
    • Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy
    • Low D, Dempsey J, Venkatesan R, et al. Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy. Med Phys. 1999;26(8):1542-51.
    • (1999) Med Phys , vol.26 , Issue.8 , pp. 1542-1551
    • Low, D.1    Dempsey, J.2    Venkatesan, R.3
  • 20
    • 0742271772 scopus 로고    scopus 로고
    • Validation and application of polymer gel dosimetry for the dose verification of an intensity-modulated arc therapy (IMAT) treatment
    • Vergote K, De Deene Y, Duthoy W, et al. Validation and application of polymer gel dosimetry for the dose verification of an intensity-modulated arc therapy (IMAT) treatment. Phys Med Biol. 2004;49(2):287-305.
    • (2004) Phys Med Biol , vol.49 , Issue.2 , pp. 287-305
    • Vergote, K.1    De Deene, Y.2    Duthoy, W.3
  • 21
    • 34748868975 scopus 로고    scopus 로고
    • Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements
    • Pallotta S, Marrazzo L, Bucciolini M. Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements. Med Phys. 2007;34(10):3724-31.
    • (2007) Med Phys , vol.34 , Issue.10 , pp. 3724-3731
    • Pallotta, S.1    Marrazzo, L.2    Bucciolini, M.3
  • 22
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • Jursinic P and Nelms B. A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery. Med Phys. 2003;30(5):870-79.
    • (2003) Med Phys , vol.30 , Issue.5 , pp. 870-879
    • Jursinic, P.1    Nelms, B.2
  • 23
    • 22244450090 scopus 로고    scopus 로고
    • Characterization of a 2D ion chamber array for the verification of radiotherapy treatments
    • Spezi E, Angelini A, Romani F, Ferri A. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments. Phys Med Biol. 2005;50(14):3361-73.
    • (2005) Phys Med Biol , vol.50 , Issue.14 , pp. 3361-3373
    • Spezi, E.1    Angelini, A.2    Romani, F.3    Ferri, A.4
  • 24
    • 33645511871 scopus 로고    scopus 로고
    • Two-dimensional ionization chamber arrays for IMRT plan verification
    • Poppe B, Blechschmidt A, Djouguela A, et al. Two-dimensional ionization chamber arrays for IMRT plan verification. Med Phys. 2006;33(4):1005-15.
    • (2006) Med Phys , vol.33 , Issue.4 , pp. 1005-1015
    • Poppe, B.1    Blechschmidt, A.2    Djouguela, A.3
  • 25
    • 77953518833 scopus 로고    scopus 로고
    • MapCHECK used for rotational IMRT measurements: step-and-shoot, TomoTherapy, RapidArc
    • Jursinic PA, Sharma R, Reuter J. MapCHECK used for rotational IMRT measurements: step-and-shoot, TomoTherapy, RapidArc. Med Phys. 2010;37(6):2837-46.
    • (2010) Med Phys , vol.37 , Issue.6 , pp. 2837-2846
    • Jursinic, P.A.1    Sharma, R.2    Reuter, J.3
  • 26
    • 51849154948 scopus 로고    scopus 로고
    • Monte Carlo simulation of RapidArc radiotherapy delivery
    • Bush K, Townson R, Zavgorodni S. Monte Carlo simulation of RapidArc radiotherapy delivery. Phys Med Biol. 2008;53(19):N359-N370.
    • (2008) Phys Med Biol , vol.53 , Issue.19
    • Bush, K.1    Townson, R.2    Zavgorodni, S.3
  • 27
    • 65449118359 scopus 로고    scopus 로고
    • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy
    • Letourneau D, Publicover J, Kozelka J, Moseley DJ, Jaffray DA. Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy. Med Phys. 2009;36(5):1813-21.
    • (2009) Med Phys , vol.36 , Issue.5 , pp. 1813-1821
    • Letourneau, D.1    Publicover, J.2    Kozelka, J.3    Moseley, D.J.4    Jaffray, D.A.5
  • 28
    • 67649889107 scopus 로고    scopus 로고
    • Evaluation of the Delta4 phantom for IMRT and VMAT verification
    • Bedford J, Lee Y, Wai P, South C, Warrington A. Evaluation of the Delta4 phantom for IMRT and VMAT verification. Phys Med Biol. 2009;54(9):N167-N176.
    • (2009) Phys Med Biol , vol.54 , Issue.9
    • Bedford, J.1    Lee, Y.2    Wai, P.3    South, C.4    Warrington, A.5
  • 30
    • 66449086805 scopus 로고    scopus 로고
    • Development and evaluation of an efficient approach to volumetric arc therapy planning
    • Bzdusek K, Friberger H, Eriksson K, Hardemark B, Robinson D, Kaus M. Development and evaluation of an efficient approach to volumetric arc therapy planning. Med Phys. 2009;36(6):2328-39.
    • (2009) Med Phys , vol.36 , Issue.6 , pp. 2328-2339
    • Bzdusek, K.1    Friberger, H.2    Eriksson, K.3    Hardemark, B.4    Robinson, D.5    Kaus, M.6
  • 31
    • 73649086212 scopus 로고    scopus 로고
    • Calibration of a novel four-dimensional diode array
    • Yan G, Lu B, Kozelka J, Liu C, Li JG. Calibration of a novel four-dimensional diode array. Med Phys. 2010;37(1):108-15.
    • (2010) Med Phys , vol.37 , Issue.1 , pp. 108-115
    • Yan, G.1    Lu, B.2    Kozelka, J.3    Liu, C.4    Li, J.G.5
  • 32
    • 69649105188 scopus 로고    scopus 로고
    • Task Group 142 report: quality assurance of medical accelerators
    • Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: quality assurance of medical accelerators. Med Phys. 2009;36(9):4197-212.
    • (2009) Med Phys , vol.36 , Issue.9 , pp. 4197-4212
    • Klein, E.E.1    Hanley, J.2    Bayouth, J.3
  • 33
    • 31044444873 scopus 로고    scopus 로고
    • The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator
    • Sharpe MB, Moseley DJ, Purdie TG, Islam M, Siewerdsen J, Jaffray D. The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. Med Phys. 2006;33(1):136-44.
    • (2006) Med Phys , vol.33 , Issue.1 , pp. 136-144
    • Sharpe, M.B.1    Moseley, D.J.2    Purdie, T.G.3    Islam, M.4    Siewerdsen, J.5    Jaffray, D.6
  • 34
    • 33847306482 scopus 로고    scopus 로고
    • Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table
    • Meyer J, Wilbert J, Baier K, et al. Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table. Int J Radiat Oncol Biol Phys. 2007;67(4):1220-28.
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , Issue.4 , pp. 1220-1228
    • Meyer, J.1    Wilbert, J.2    Baier, K.3
  • 35
    • 44349152982 scopus 로고    scopus 로고
    • An analysis of tolerance levels in IMRT quality assurance procedures
    • Basran PS and Woo MK. An analysis of tolerance levels in IMRT quality assurance procedures. Med Phys. 2008;35(6):2300-07.
    • (2008) Med Phys , vol.35 , Issue.6 , pp. 2300-2307
    • Basran, P.S.1    Woo, M.K.2
  • 36
    • 60549084371 scopus 로고    scopus 로고
    • Dosimetric verification of RapidArc treatment delivery
    • Korreman S, Medin J, Kjaer-Kristoffersen F. Dosimetric verification of RapidArc treatment delivery. Acta Oncol. 2009;48(2):185-91.
    • (2009) Acta Oncol , vol.48 , Issue.2 , pp. 185-191
    • Korreman, S.1    Medin, J.2    Kjaer-Kristoffersen, F.3
  • 37
    • 79960552723 scopus 로고    scopus 로고
    • Evaluation of a new VMAT QA device, or the "X" and "O" array geometries
    • Feygelman V, Zhang G, Stevens C, Nelms BE. Evaluation of a new VMAT QA device, or the "X" and "O" array geometries. J Appl Clin Med Phys. 2011;12(2):146-68.
    • (2011) J Appl Clin Med Phys , vol.12 , Issue.2 , pp. 146-168
    • Feygelman, V.1    Zhang, G.2    Stevens, C.3    Nelms, B.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.