메뉴 건너뛰기




Volumn 32, Issue 9, 2013, Pages

Study of agreement of aortic, radial and femoral blood pressures during aortic endografting

Author keywords

Aortic endografting; Ascending aorta; Invasive arterial pressure monitoring; Limits of agreement; Radial and femoral arteries

Indexed keywords

ACCURACY; AORTA ENDOGRAFTING; AORTA GRAFT; AORTA PRESSURE; AORTA PROSTHESIS; ARTICLE; ASCENDING AORTA; BLOOD PRESSURE; BLOOD PRESSURE MONITORING; CLINICAL ARTICLE; COMPARATIVE STUDY; DIASTOLIC BLOOD PRESSURE; FEMALE; FEMORAL BLOOD PRESSURE; GENERAL ANESTHESIA; HEMODYNAMIC MONITORING; HUMAN; MALE; MEAN ARTERIAL PRESSURE; OBSERVATIONAL STUDY; PREDICTIVE VALUE; PROSPECTIVE STUDY; RADIAL BLOOD PRESSURE; SYSTOLIC BLOOD PRESSURE;

EID: 84884145009     PISSN: 07507658     EISSN: 17696623     Source Type: Journal    
DOI: 10.1016/j.annfar.2013.06.011     Document Type: Article
Times cited : (5)

References (22)
  • 1
    • 0034051418 scopus 로고    scopus 로고
    • Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
    • Bur A., Hirschl M.M., Herkner H., Oschatz E., Kofler J., Woisetschlager C., et al. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. Crit Care Med 2000, 28:371-376.
    • (2000) Crit Care Med , vol.28 , pp. 371-376
    • Bur, A.1    Hirschl, M.M.2    Herkner, H.3    Oschatz, E.4    Kofler, J.5    Woisetschlager, C.6
  • 2
    • 0141676841 scopus 로고    scopus 로고
    • Pulse pressure and arterial stiffness in rats: comparison with humans
    • Safar M., Laurent P. Pulse pressure and arterial stiffness in rats: comparison with humans. Am J Physiol Heart Circ Physiol 2003, 285:1363-1369.
    • (2003) Am J Physiol Heart Circ Physiol , vol.285 , pp. 1363-1369
    • Safar, M.1    Laurent, P.2
  • 3
    • 0026753406 scopus 로고
    • Does radial artery pressure accurately reflect aortic pressure
    • Pauca A.L., Wallenhaupt S.L., Kon N.D., Tucker W.Y. Does radial artery pressure accurately reflect aortic pressure. Chest 1992, 102:1193-1198.
    • (1992) Chest , vol.102 , pp. 1193-1198
    • Pauca, A.L.1    Wallenhaupt, S.L.2    Kon, N.D.3    Tucker, W.Y.4
  • 4
    • 0026688843 scopus 로고
    • Differences between aortic and radial artery pressure associated with cardiopulmonary bypass
    • Rich G.F., Lubanski R.E., McLoughlin T.M. Differences between aortic and radial artery pressure associated with cardiopulmonary bypass. Anesthesiology 1992, 77:63-66.
    • (1992) Anesthesiology , vol.77 , pp. 63-66
    • Rich, G.F.1    Lubanski, R.E.2    McLoughlin, T.M.3
  • 5
    • 0025337053 scopus 로고
    • Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery
    • Bazaral M.G., Welch M., Golding L.A., Badhwar K. Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery. Anesthesiology 1990, 73:38-45.
    • (1990) Anesthesiology , vol.73 , pp. 38-45
    • Bazaral, M.G.1    Welch, M.2    Golding, L.A.3    Badhwar, K.4
  • 6
    • 0021966475 scopus 로고
    • Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass
    • Stern D.H., Gerson J.I., Allen F.B., Parker F.B. Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass. Anesthesiology 1985, 62:557-561.
    • (1985) Anesthesiology , vol.62 , pp. 557-561
    • Stern, D.H.1    Gerson, J.I.2    Allen, F.B.3    Parker, F.B.4
  • 7
    • 0030787478 scopus 로고    scopus 로고
    • Radial artery diameter decreases with increased femoral to radial arterial pressure gradient during cardiopulmonary bypass
    • Baba T., Goto T., Yoshitake A., Shibata Y. Radial artery diameter decreases with increased femoral to radial arterial pressure gradient during cardiopulmonary bypass. Anesth Analg 1997, 85:252-258.
    • (1997) Anesth Analg , vol.85 , pp. 252-258
    • Baba, T.1    Goto, T.2    Yoshitake, A.3    Shibata, Y.4
  • 8
    • 0031717777 scopus 로고    scopus 로고
    • Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients
    • Dorman T., Breslow M.J., Lipsett P.A., Rosenberg J.M., Balser J.R., Almog Y., et al. Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med 1998, 26:1646-1649.
    • (1998) Crit Care Med , vol.26 , pp. 1646-1649
    • Dorman, T.1    Breslow, M.J.2    Lipsett, P.A.3    Rosenberg, J.M.4    Balser, J.R.5    Almog, Y.6
  • 10
    • 0028037508 scopus 로고
    • Thermoregulatory and anesthetic-induced alterations in the differences among femoral, radial, and oscillometric blood pressures
    • Hynson J.M., Sessler D.I., Moayeri A., Katz J.A. Thermoregulatory and anesthetic-induced alterations in the differences among femoral, radial, and oscillometric blood pressures. Anesthesiology 1994, 81:1411-1421.
    • (1994) Anesthesiology , vol.81 , pp. 1411-1421
    • Hynson, J.M.1    Sessler, D.I.2    Moayeri, A.3    Katz, J.A.4
  • 11
    • 0025171446 scopus 로고
    • Effect of combined infusion of nitroglycerin and nicardipine on femoral-to-radial arterial pressure gradient after cardiopulmonary bypass
    • Maruyama K., Horiguchi R., Hashimoto H., Ohi Y., Okuda M., Kurioka T., et al. Effect of combined infusion of nitroglycerin and nicardipine on femoral-to-radial arterial pressure gradient after cardiopulmonary bypass. Anesth Analg 1990, 70:428-432.
    • (1990) Anesth Analg , vol.70 , pp. 428-432
    • Maruyama, K.1    Horiguchi, R.2    Hashimoto, H.3    Ohi, Y.4    Okuda, M.5    Kurioka, T.6
  • 12
    • 0038110704 scopus 로고    scopus 로고
    • Relationship between aortic-to-radial arterial pressure gradient after cardiopulmonary bypass and changes in arterial elasticity
    • Kanazawa M., Fukuyama H., Kinefuchi Y., Takiguchi M., Suzuki T. Relationship between aortic-to-radial arterial pressure gradient after cardiopulmonary bypass and changes in arterial elasticity. Anesthesiology 2003, 99:48-53.
    • (2003) Anesthesiology , vol.99 , pp. 48-53
    • Kanazawa, M.1    Fukuyama, H.2    Kinefuchi, Y.3    Takiguchi, M.4    Suzuki, T.5
  • 13
    • 0033847206 scopus 로고    scopus 로고
    • Effects of perfusion pressure on tissue perfusion in septic shock
    • LeDoux D., Astiz M.E., Carpati C.M., Rackow E.C. Effects of perfusion pressure on tissue perfusion in septic shock. Crit Care Med 2000, 28:2729-2732.
    • (2000) Crit Care Med , vol.28 , pp. 2729-2732
    • LeDoux, D.1    Astiz, M.E.2    Carpati, C.M.3    Rackow, E.C.4
  • 14
    • 17044421757 scopus 로고    scopus 로고
    • Increasing mean arterial pressure in patients with septic shock: effects on oxygen variables and renal function
    • Bourgoin A., Leone M., Delmas A., Garnier F., Albanese J., Martin C. Increasing mean arterial pressure in patients with septic shock: effects on oxygen variables and renal function. Crit Care Med 2005, 33:780-786.
    • (2005) Crit Care Med , vol.33 , pp. 780-786
    • Bourgoin, A.1    Leone, M.2    Delmas, A.3    Garnier, F.4    Albanese, J.5    Martin, C.6
  • 15
    • 34347222567 scopus 로고    scopus 로고
    • Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006
    • Antonelli M., Levy M., Andrews P.J., Chastre J., Hudson L.D., Manthous C., et al. Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006. Intensive Care Med 2007, 33:575-590.
    • (2007) Intensive Care Med , vol.33 , pp. 575-590
    • Antonelli, M.1    Levy, M.2    Andrews, P.J.3    Chastre, J.4    Hudson, L.D.5    Manthous, C.6
  • 16
    • 84873714375 scopus 로고    scopus 로고
    • Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012
    • Dellinger R.P., Levy M.M., Rhodes A., Annane D., Gerlach H., Opal S.M., et al. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med 2013, 39:165-228.
    • (2013) Intensive Care Med , vol.39 , pp. 165-228
    • Dellinger, R.P.1    Levy, M.M.2    Rhodes, A.3    Annane, D.4    Gerlach, H.5    Opal, S.M.6
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 33846231551 scopus 로고    scopus 로고
    • Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study
    • Mignini M.A., Piacentini E., Dubin A. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study. Crit Care 2006, 10:R43.
    • (2006) Crit Care , vol.10
    • Mignini, M.A.1    Piacentini, E.2    Dubin, A.3
  • 19
    • 0026485318 scopus 로고
    • Hemodynamic and organ blood flow responses to halothane and sevoflurane anesthesia during spontaneous ventilation
    • Crawford M.W., Lerman J., Saldivia V., Carmichael F.J. Hemodynamic and organ blood flow responses to halothane and sevoflurane anesthesia during spontaneous ventilation. Anesth Analg 1992, 75:1000-1006.
    • (1992) Anesth Analg , vol.75 , pp. 1000-1006
    • Crawford, M.W.1    Lerman, J.2    Saldivia, V.3    Carmichael, F.J.4
  • 20
    • 84884168595 scopus 로고    scopus 로고
    • Arterial Compliance
    • Springer, London, Willerson, Wellens, Cohn, Holmes (Eds.)
    • McVeigh G., Bank A., Cohn J. Arterial Compliance. Cardiovascular Medicine 2007, 1811-1831. Springer, London. Willerson, Wellens, Cohn, Holmes (Eds.).
    • (2007) Cardiovascular Medicine , pp. 1811-1831
    • McVeigh, G.1    Bank, A.2    Cohn, J.3
  • 21
    • 33746211575 scopus 로고    scopus 로고
    • Endografting of the descending thoracic aorta increases ascending aortic input impedance and attenuates pressure transmission in dogs
    • Dobson G., Flewitt J., Tyberg J.V., Moore R., Karamanoglu M. Endografting of the descending thoracic aorta increases ascending aortic input impedance and attenuates pressure transmission in dogs. Eur J Vasc Endovasc Surg 2006, 32:129-135.
    • (2006) Eur J Vasc Endovasc Surg , vol.32 , pp. 129-135
    • Dobson, G.1    Flewitt, J.2    Tyberg, J.V.3    Moore, R.4    Karamanoglu, M.5
  • 22
    • 15744372765 scopus 로고    scopus 로고
    • Clinical measurement of arterial stiffness obtained from non-invasive pressure waveforms
    • Nichols W.W. Clinical measurement of arterial stiffness obtained from non-invasive pressure waveforms. Am J Hypertens 2005, 18:3S-10S.
    • (2005) Am J Hypertens , vol.18
    • Nichols, W.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.