메뉴 건너뛰기




Volumn 68, Issue 10, 2013, Pages 1010-1020

The ability of bispectral index to detect intra-operative wakefulness during isoflurane/air anaesthesia, compared with the isolated forearm technique

Author keywords

[No Author keywords available]

Indexed keywords

ATRACURIUM BESILATE; ISOFLURANE;

EID: 84884137312     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/anae.12357     Document Type: Article
Times cited : (38)

References (42)
  • 2
    • 2542562742 scopus 로고    scopus 로고
    • Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial
    • for the B-Aware trial group.
    • Myles PS, Leslie K, McNeil J, Forbes A, Chan MTV, for the B-Aware trial group. Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial. Lancet 2004; 363: 1757-63.
    • (2004) Lancet , vol.363 , pp. 1757-1763
    • Myles, P.S.1    Leslie, K.2    McNeil, J.3    Forbes, A.4    Chan, M.T.V.5
  • 4
    • 84860389403 scopus 로고    scopus 로고
    • Prevention of intraoperative awareness in a high-risk surgical population
    • et al.
    • Avidan MS, Jacobsohn E, Glick D, et al. Prevention of intraoperative awareness in a high-risk surgical population. New England Journal of Medicine 2011; 365: 591-600.
    • (2011) New England Journal of Medicine , vol.365 , pp. 591-600
    • Avidan, M.S.1    Jacobsohn, E.2    Glick, D.3
  • 5
    • 84866707863 scopus 로고    scopus 로고
    • Prevention of intraoperative awareness with explicit recall in an unselected surgical population. A randomized comparative effectiveness trial
    • et al.
    • Mashour GA, Shanks A, Tremper KK, et al. Prevention of intraoperative awareness with explicit recall in an unselected surgical population. A randomized comparative effectiveness trial. Anesthesiology 2012; 117: 717-25.
    • (2012) Anesthesiology , vol.117 , pp. 717-725
    • Mashour, G.A.1    Shanks, A.2    Tremper, K.K.3
  • 6
    • 84884160522 scopus 로고    scopus 로고
    • National Institute for Health and Care Excellence. Depth of anaesthesia monitors - Bispectral Index (BIS), E-Entropy and Narcotrend-Compact M. NICE diagnostics guidance 6; November 2012 (accessed 06/06/2013)
    • National Institute for Health and Care Excellence. Depth of anaesthesia monitors-Bispectral Index (BIS), E-Entropy and Narcotrend-Compact M. NICE diagnostics guidance 6; November 2012. http://www.nice.org.uk/nicemedia/live/ 13965/61547/61547.pdf (accessed 06/06/2013).
  • 9
    • 81855221694 scopus 로고    scopus 로고
    • Relationship between bispectral index values and volatile anesthetic concentrations during the maintenance phase of anesthesia in the B-Unaware trial
    • et al.
    • Whitlock EL, Villafranca AJ, Lin N, et al. Relationship between bispectral index values and volatile anesthetic concentrations during the maintenance phase of anesthesia in the B-Unaware trial. Anesthesiology 2011; 115: 1209-18.
    • (2011) Anesthesiology , vol.115 , pp. 1209-1218
    • Whitlock, E.L.1    Villafranca, A.J.2    Lin, N.3
  • 10
    • 0022481523 scopus 로고
    • Comparison of wakefulness with two anaesthetic regimens. Total i.v. v. balanced anaesthesia
    • Russell IF,. Comparison of wakefulness with two anaesthetic regimens. Total i.v. v. balanced anaesthesia. British Journal of Anaesthesia 1986; 58: 965-8.
    • (1986) British Journal of Anaesthesia , vol.58 , pp. 965-968
    • Russell, I.F.1
  • 11
    • 0027399920 scopus 로고
    • Midazolam-alfentanil: An anaesthetic? An investigation using the isolated forearm technique
    • Russell IF,. Midazolam-alfentanil: an anaesthetic? An investigation using the isolated forearm technique. British Journal of Anaesthesia 1993; 70: 42-6.
    • (1993) British Journal of Anaesthesia , vol.70 , pp. 42-46
    • Russell, I.F.1
  • 12
    • 0035142275 scopus 로고    scopus 로고
    • Absence of memory for intra-operative information during surgery with total intravenous anaesthesia
    • Russell IF, Wang M,. Absence of memory for intra-operative information during surgery with total intravenous anaesthesia. British Journal of Anaesthesia 2001; 86: 196-202.
    • (2001) British Journal of Anaesthesia , vol.86 , pp. 196-202
    • Russell, I.F.1    Wang, M.2
  • 13
    • 33244495314 scopus 로고    scopus 로고
    • The Narcotrend 'depth of anaesthesia' monitor cannot reliably detect consciousness during general anaesthesia: An investigation using the isolated forearm technique
    • Russell IF,. The Narcotrend 'depth of anaesthesia' monitor cannot reliably detect consciousness during general anaesthesia: an investigation using the isolated forearm technique. British Journal of Anaesthesia 2006; 96: 346-52.
    • (2006) British Journal of Anaesthesia , vol.96 , pp. 346-352
    • Russell, I.F.1
  • 14
    • 0007489001 scopus 로고
    • Detecting wakefulness during general anaesthesia for caesarean section
    • Tunstall ME,. Detecting wakefulness During general anaesthesia for caesarean section. British Medical Journal 1977; 1: 1321.
    • (1977) British Medical Journal , vol.1 , pp. 1321
    • Tunstall, M.E.1
  • 15
    • 84884144265 scopus 로고    scopus 로고
    • Implicit memory, anaesthesia and sedation
    • Davies G.W. Wright D.B. eds. London: Psychology Press.
    • Wang M,. Implicit memory, anaesthesia and sedation. In:, Davies GW, Wright DB, eds. Current Issues in Applied Memory Research. London: Psychology Press, 2010: 165-84.
    • (2010) Current Issues in Applied Memory Research , pp. 165-184
    • Wang, M.1
  • 19
    • 84867162677 scopus 로고    scopus 로고
    • The topography of awareness: A classification of intra-operative cognitive states
    • Wang M, Messina AG, Russell IF,. The topography of awareness: a classification of intra-operative cognitive states. Anaesthesia 2012; 67: 1197-201.
    • (2012) Anaesthesia , vol.67 , pp. 1197-1201
    • Wang, M.1    Messina, A.G.2    Russell, I.F.3
  • 20
    • 84876122607 scopus 로고    scopus 로고
    • The ability of bispectral index to detect intra-operative wakefulness during total intravenous anaesthesia, as compared with Isolated Forearm Technique
    • Russell IF,. The ability of bispectral index to detect intra-operative wakefulness during total intravenous anaesthesia, as compared with Isolated Forearm Technique. Anaesthesia 2013; 68: 502-11.
    • (2013) Anaesthesia , vol.68 , pp. 502-511
    • Russell, I.F.1
  • 21
    • 84879118606 scopus 로고    scopus 로고
    • The place of the isolated forearm technique in modern anaesthesia: Yet to be defined
    • Sleigh J,. The place of the isolated forearm technique in modern anaesthesia: yet to be defined. Anaesthesia 2013; 68: 681-3.
    • (2013) Anaesthesia , vol.68 , pp. 681-683
    • Sleigh, J.1
  • 22
    • 84879118217 scopus 로고    scopus 로고
    • Fourteen fallacies about the isolated forearm technique, and its place in modern anaesthesia
    • Russell IF,. Fourteen fallacies about the isolated forearm technique, and its place in modern anaesthesia. Anaesthesia 2013; 68: 677-81.
    • (2013) Anaesthesia , vol.68 , pp. 677-681
    • Russell, I.F.1
  • 23
    • 0031955972 scopus 로고    scopus 로고
    • The influence of method of administration and the covariates on the pharmacokinetics of propofol in adult volunteers
    • Schneider TW, Minto CF, Gambus PL,. The influence of method of administration and the covariates on the pharmacokinetics of propofol in adult volunteers. Anesthesiology 1998; 88: 1170-82.
    • (1998) Anesthesiology , vol.88 , pp. 1170-1182
    • Schneider, T.W.1    Minto, C.F.2    Gambus, P.L.3
  • 24
    • 84884142400 scopus 로고    scopus 로고
    • Monitoring consciousness using the Bispectral Index during anesthesia. A Pocket Guide for Clinicians. Covidien (accessed 06/06/2013)
    • Kelly SD,. Monitoring consciousness using the Bispectral Index during anesthesia. A Pocket Guide for Clinicians. Covidien. http://www.biseducation. com/uploadedfiles/assets/0000000012.pdf (accessed 06/06/2013).
    • Kelly, S.D.1
  • 26
    • 0036239088 scopus 로고    scopus 로고
    • Titration of isoflurane using BIS index improves early recovery of elderly patients undergoing orthopedic surgeries
    • Wong J, Song D, Blanshard H, Grady D, Chung F,. Titration of isoflurane using BIS index improves early recovery of elderly patients undergoing orthopedic surgeries. Canadian Journal of Anesthesia 2002; 49: 13-8.
    • (2002) Canadian Journal of Anesthesia , vol.49 , pp. 13-18
    • Wong, J.1    Song, D.2    Blanshard, H.3    Grady, D.4    Chung, F.5
  • 27
    • 84875131304 scopus 로고    scopus 로고
    • A national survey of anaesthetists (NAP5 Baseline) to estimate an annual incidence of accidental awareness during general anaesthesia in the UK
    • Pandit JJ, Cook TM, Jonker WR, O'Sullivan E,. A national survey of anaesthetists (NAP5 Baseline) to estimate an annual incidence of accidental awareness during general anaesthesia in the UK. Anaesthesia 2013; 68: 343-53.
    • (2013) Anaesthesia , vol.68 , pp. 343-353
    • Pandit, J.J.1    Cook, T.M.2    Jonker, W.R.3    O'Sullivan, E.4
  • 29
    • 0042830525 scopus 로고    scopus 로고
    • Detection of awareness in surgical patients with EEG-based indices-bispectral index and patient state index
    • Schneider G, Gelb AW, Schmeller B, Tschakert R, Kochs E,. Detection of awareness in surgical patients with EEG-based indices-bispectral index and patient state index. British Journal of Anaesthesia 2003; 91: 329-35.
    • (2003) British Journal of Anaesthesia , vol.91 , pp. 329-335
    • Schneider, G.1    Gelb, A.W.2    Schmeller, B.3    Tschakert, R.4    Kochs, E.5
  • 30
    • 0033860992 scopus 로고    scopus 로고
    • Bispectral analysis of the electroencephalogram does not predict responsiveness to verbal command in patients emerging from xenon anaesthesia
    • et al.
    • Goto T, Nakata Y, Saito H, et al. Bispectral analysis of the electroencephalogram does not predict responsiveness to verbal command in patients emerging from xenon anaesthesia. British Journal of Anaesthesia 2000; 85: 359-63.
    • (2000) British Journal of Anaesthesia , vol.85 , pp. 359-363
    • Goto, T.1    Nakata, Y.2    Saito, H.3
  • 31
    • 1942468901 scopus 로고    scopus 로고
    • The relationship between Bispectral Index and Electroencephalographic parameters during isoflurane anesthesia
    • Morimoto Y, Hagihira S, Koizumi Y, Ishida K, Matsumoto M, Sakabe T,. The relationship between Bispectral Index and Electroencephalographic parameters during isoflurane anesthesia. Anesthesia and Analgesia 2004; 98: 1336-40.
    • (2004) Anesthesia and Analgesia , vol.98 , pp. 1336-1340
    • Morimoto, Y.1    Hagihira, S.2    Koizumi, Y.3    Ishida, K.4    Matsumoto, M.5    Sakabe, T.6
  • 32
    • 0033988636 scopus 로고    scopus 로고
    • Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients
    • Detsch O, Schneider G, Kochs E, Hapfelmeier G, Werner C,. Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients. British Journal of Anaesthesia 2000; 84: 33-7.
    • (2000) British Journal of Anaesthesia , vol.84 , pp. 33-37
    • Detsch, O.1    Schneider, G.2    Kochs, E.3    Hapfelmeier, G.4    Werner, C.5
  • 33
    • 0036293927 scopus 로고    scopus 로고
    • The relationship between end-tidal isoflurane concentration and electroencephalographic bispectral index during isoflurane/epidural anesthesia
    • Kurehara K, Takahashi M, Kitaguchi K, Furuya H,. The relationship between end-tidal isoflurane concentration and electroencephalographic bispectral index during isoflurane/epidural anesthesia. Masui 2002; 51: 642-7.
    • (2002) Masui , vol.51 , pp. 642-647
    • Kurehara, K.1    Takahashi, M.2    Kitaguchi, K.3    Furuya, H.4
  • 34
    • 0032420796 scopus 로고    scopus 로고
    • Unreasonably low Bispectral Index values in a volunteer with genetically determined low-voltage electroencephalographic signal
    • Schnider TW, Luginbuhl M, Petersen-Felix S, Mathis J,. Unreasonably low Bispectral Index values in a volunteer with genetically determined low-voltage electroencephalographic signal. Anesthesiology 1998; 89: 1607-8.
    • (1998) Anesthesiology , vol.89 , pp. 1607-1608
    • Schnider, T.W.1    Luginbuhl, M.2    Petersen-Felix, S.3    Mathis, J.4
  • 35
    • 84876099272 scopus 로고    scopus 로고
    • Minimum alveolar concentration: Ongoing relevance and clinical utility
    • Arnake A, Mashour GA, Avidan MS,. Minimum alveolar concentration: ongoing relevance and clinical utility. Anaesthesia 2013; 68: 512-22.
    • (2013) Anaesthesia , vol.68 , pp. 512-522
    • Arnake, A.1    Mashour, G.A.2    Avidan, M.S.3
  • 36
    • 0038637263 scopus 로고    scopus 로고
    • Biasing effect of the electromyogram on BIS: A controlled study during high-dose fentanyl induction
    • Renna M, Wigmore T, Mofeez A, Gillbe C,. Biasing effect of the electromyogram on BIS: a controlled study during high-dose fentanyl induction. Journal of Clinical Monitoring and Computing 2002; 17: 377-81.
    • (2002) Journal of Clinical Monitoring and Computing , vol.17 , pp. 377-381
    • Renna, M.1    Wigmore, T.2    Mofeez, A.3    Gillbe, C.4
  • 37
    • 79851491059 scopus 로고    scopus 로고
    • Comparison of the ability of wavelet index and bispectral index for reflecting regain of consciousness in patients undergone surgery
    • Zhang X, Cheng H, Xiong W, Wang B,. Comparison of the ability of wavelet index and bispectral index for reflecting regain of consciousness in patients undergone surgery. Chinese Medical Journal (Engl) 2010; 123: 1520-3.
    • (2010) Chinese Medical Journal (Engl) , vol.123 , pp. 1520-1523
    • Zhang, X.1    Cheng, H.2    Xiong, W.3    Wang, B.4
  • 38
    • 84874394200 scopus 로고    scopus 로고
    • National Institute for Clinical Excellence guidance on measuring depth of anaesthesia: Limitations of EEG-based technology
    • Pandit JJ, Cook TM,. National Institute for Clinical Excellence guidance on measuring depth of anaesthesia: limitations of EEG-based technology. British Journal of Anaesthesia 2013; 110: 325-8.
    • (2013) British Journal of Anaesthesia , vol.110 , pp. 325-328
    • Pandit, J.J.1    Cook, T.M.2
  • 39
    • 84863791625 scopus 로고    scopus 로고
    • Conscious processing: Implications for general anesthesia
    • Changeux J-PG,. Conscious processing: implications for general anesthesia. Current Opinion in Anesthesiology 2012; 25: 397-404.
    • (2012) Current Opinion in Anesthesiology , vol.25 , pp. 397-404
    • Changeux, J.-P.1
  • 40
    • 84856828934 scopus 로고    scopus 로고
    • Monitoring the brain in cardiac surgery - An evolving area for research
    • Grocott HP,. Monitoring the brain in cardiac surgery-an evolving area for research. Anaesthesia 2012; 67: 216-9.
    • (2012) Anaesthesia , vol.67 , pp. 216-219
    • Grocott, H.P.1
  • 41
    • 0034716487 scopus 로고    scopus 로고
    • Awareness during anaesthesia: A prospective case study
    • Sandin RH, Enlund G, Samuelsson P, Lennmarken C,. Awareness during anaesthesia: a prospective case study. Lancet 2000; 355: 707-11.
    • (2000) Lancet , vol.355 , pp. 707-711
    • Sandin, R.H.1    Enlund, G.2    Samuelsson, P.3    Lennmarken, C.4
  • 42
    • 0031015716 scopus 로고    scopus 로고
    • Absence of memory for intraoperative information during surgery under adequate general anaesthesia
    • Russell IF, Wang M,. Absence of memory for intraoperative information during surgery under adequate general anaesthesia. British Journal of Anaesthesia 1997; 78: 3-9.
    • (1997) British Journal of Anaesthesia , vol.78 , pp. 3-9
    • Russell, I.F.1    Wang, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.