Risk of injury to rescuers who use hands-on defibrillation

Author keywords

[No Author keywords available]

Indexed keywords

CLINICAL EXAMINATION; CLINICAL PRACTICE; DEFIBRILLATION; ELECTRIC CURRENT; ELECTRIC RESISTANCE; ELECTRIC SHOCK; HANDS ON DEFIBRILLATION; HUMAN; LETTER; MYALGIA; PATIENT SAFETY; PERCEPTION; PERCEPTIVE THRESHOLD; PERFORATION; PERSONAL EXPERIENCE; PRIORITY JOURNAL; RESUSCITATION; RISK FACTOR; SENSATION; SHOCK;

EID: 84884136482     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2013.04.031     Document Type: Letter
Times cited : (2)

References (10)
  • 1
    • 84876743704 scopus 로고    scopus 로고
    • Perhaps crying "clear" should be left to the TV actors?
    • [in press]
    • Kurz M.C., Sawyer K.N. Perhaps crying "clear" should be left to the TV actors?. Resuscitation 2013, [in press].
    • (2013) Resuscitation
    • Kurz, M.C.1    Sawyer, K.N.2
  • 2
    • 43449089813 scopus 로고    scopus 로고
    • Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation
    • Lloyd M.S., Heeke B., Walter P.F., Langberg J.J. Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation. Circulation 2008, 117:2510-2514.
    • (2008) Circulation , vol.117 , pp. 2510-2514
    • Lloyd, M.S.1    Heeke, B.2    Walter, P.F.3    Langberg, J.J.4
  • 3
    • 84876739760 scopus 로고    scopus 로고
    • Hands-on defibrillation has the potential to improve the quality of cardiopulmonary resuscitation and is safe for rescuers - a preclinical study
    • Neumann T., Gruenewald M., Lauenstein C., Drews T., Iden T., Meybohm P. Hands-on defibrillation has the potential to improve the quality of cardiopulmonary resuscitation and is safe for rescuers - a preclinical study. J Am Heart Assoc 2012, 1:e001313.
    • (2012) J Am Heart Assoc , vol.1
    • Neumann, T.1    Gruenewald, M.2    Lauenstein, C.3    Drews, T.4    Iden, T.5    Meybohm, P.6
  • 4
    • 84859980558 scopus 로고    scopus 로고
    • Hands-on defibrillation: theoretical and practical aspects of patient and rescuer safety
    • Petley G.W., Cotton A.M., Deakin C.D. Hands-on defibrillation: theoretical and practical aspects of patient and rescuer safety. Resuscitation 2012, 83:551-556.
    • (2012) Resuscitation , vol.83 , pp. 551-556
    • Petley, G.W.1    Cotton, A.M.2    Deakin, C.D.3
  • 5
    • 84878869588 scopus 로고    scopus 로고
    • Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? I: resistive properties of nitrile gloves
    • Deakin C.D., Lee-Shrewsbury V., Hogg K., Petley G. Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? I: resistive properties of nitrile gloves. Resuscitation 2013, 84:895-899.
    • (2013) Resuscitation , vol.84 , pp. 895-899
    • Deakin, C.D.1    Lee-Shrewsbury, V.2    Hogg, K.3    Petley, G.4
  • 6
    • 58149235569 scopus 로고    scopus 로고
    • Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation
    • Sullivan J.L. Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation. Circulation 2008, 118:e712.
    • (2008) Circulation , vol.118
    • Sullivan, J.L.1
  • 7
    • 84878877455 scopus 로고    scopus 로고
    • Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? II: material integrity following exposure to defibrillation waveforms
    • Petley G.W., Deakin C.D. Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? II: material integrity following exposure to defibrillation waveforms. Resuscitation 2013, 84:900-903.
    • (2013) Resuscitation , vol.84 , pp. 900-903
    • Petley, G.W.1    Deakin, C.D.2
  • 8
    • 84868200656 scopus 로고    scopus 로고
    • Will medical examination gloves protect rescuers from defibrillation voltages during hands-on defibrillation?
    • Sullivan J.L., Chapman F.W. Will medical examination gloves protect rescuers from defibrillation voltages during hands-on defibrillation?. Resuscitation 2012, 83:1467-1472.
    • (2012) Resuscitation , vol.83 , pp. 1467-1472
    • Sullivan, J.L.1    Chapman, F.W.2
  • 9
    • 84884162792 scopus 로고    scopus 로고
    • Abstract 107: performing hands-on defibrillation in out-of-hospital cardiac arrest can result in the mild, subjective perception of current to providers
    • Johnson T., Meersman J., Youngquist S.T. Abstract 107: performing hands-on defibrillation in out-of-hospital cardiac arrest can result in the mild, subjective perception of current to providers. Circulation 2012, 126:A107.
    • (2012) Circulation , vol.126
    • Johnson, T.1    Meersman, J.2    Youngquist, S.T.3
  • 10
    • 84875053091 scopus 로고    scopus 로고
    • A note of caution on the performance of hands-on biphasic defibrillation
    • Weingart S.D. A note of caution on the performance of hands-on biphasic defibrillation. Resuscitation 2013, 84:e53.
    • (2013) Resuscitation , vol.84
    • Weingart, S.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.