메뉴 건너뛰기




Volumn 5761 LNCS, Issue PART 1, 2009, Pages 100-107

Correcting motion artifacts in retinal spectral domain optical coherence tomography via image registration

Author keywords

[No Author keywords available]

Indexed keywords

IMAGING PROCESS; IN-VESSEL; MICROSACCADES; MOTION ARTIFACT; REFERENCE IMAGE; RETINAL DISEASE; SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHIES; STRUCTURAL CHANGE; TRANSVERSE MOTIONS; VISION LOSS;

EID: 84883834511     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-04268-3_13     Document Type: Conference Paper
Times cited : (81)

References (10)
  • 1
    • 25844456000 scopus 로고    scopus 로고
    • Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography
    • Wojtkowski, M., Srinivasan, V., Fujimoto, J., Ko, T., Schuman, J., Kowalczyk, A., Duker, J.: Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. Ophthalmology 112(10) (2005)
    • (2005) Ophthalmology , vol.112 , Issue.10
    • Wojtkowski, M.1    Srinivasan, V.2    Fujimoto, J.3    Ko, T.4    Schuman, J.5    Kowalczyk, A.6    Duker, J.7
  • 2
    • 0036822851 scopus 로고    scopus 로고
    • Reduction of intraocular pressure and glaucoma progression results from the Early Manifest Glaucoma Trial
    • Heijl, A., Leske, M., Bengtsson, B., Hyman, L., Bengtsson, B., Hussein, M.: Reduction of intraocular pressure and glaucoma progression results from the Early Manifest Glaucoma Trial. Archives of Ophthalmology 120(10) (2002)
    • (2002) Archives of Ophthalmology , vol.120 , Issue.10
    • Heijl, A.1    Leske, M.2    Bengtsson, B.3    Hyman, L.4    Bengtsson, B.5    Hussein, M.6
  • 6
    • 34548238750 scopus 로고    scopus 로고
    • Correction of motion artifacts and scanning beam distortions in 3D ophthalmic optical coherence tomography imaging
    • Zawadzki, R., Fuller, A., Choi, S., Wiley, D., Hamann, B., Werner, J.: Correction of motion artifacts and scanning beam distortions in 3D ophthalmic optical coherence tomography imaging. Ophthalmic Technologies XVII 6426(1) (2007)
    • (2007) Ophthalmic Technologies XVII , vol.6426 , Issue.1
    • Zawadzki, R.1    Fuller, A.2    Choi, S.3    Wiley, D.4    Hamann, B.5    Werner, J.6
  • 7
    • 41649102639 scopus 로고    scopus 로고
    • A Novel Vessel Segmentation Algorithm for Pathological Retina Images Based on the Divergence of Vector Fields
    • Lam, B., Yan, H.: A Novel Vessel Segmentation Algorithm for Pathological Retina Images Based on the Divergence of Vector Fields. IEEE Transactions on Medical Imaging 27(2) (2008)
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.2
    • Lam, B.1    Yan, H.2
  • 8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.