Finite element simulations of bone temperature rise during bone drilling based on a bone analog

Author keywords

Drill bit; Drilling speed; Finite element model (FEM); Temperature distribution; Thermally affected zone

Indexed keywords

DRILLING PROCESS; DRILLING SPEED; EMPIRICAL EQUATIONS; FINITE ELEMENT SIMULATIONS; METHOD OF ANALYSIS; NUMERICAL RESULTS; TEMPERATURE RISE; THREE DIMENSIONAL FINITE ELEMENT MODEL;

EID: 84883813648     PISSN: 16090985     EISSN: None     Source Type: Journal    
DOI: 10.5405/jmbe.1366     Document Type: Article
Times cited : (66)

References (18)
  • 1
    • 0020322562 scopus 로고
    • Thermal injury to bone. A vital microscopic description of heat effects
    • A. R. Eriksson, T. Albrektsson,B.GraneandD.McQueen, "Thermal injury to bone. A vital microscopic description of heat effects," Int. J. Oral Surg., 11: 115-121, 1982.
    • (1982) Int. J. Oral Surg. , vol.11 , pp. 115-121
    • Eriksson, A.R.1    Albrektsson, T.2    Grane, B.3    McQueen, D.4
  • 2
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bonetissueinjury:A vital-microscopic study in the rabbit
    • A. R. Eriksson , T. Albrektsson, "Temperature threshold levels for heat-induced bonetissueinjury:A vital-microscopic study in the rabbit," J. Prosthet. Dent. , 50: 101-107, 1983.
    • (1983) J. Prosthet. Dent. , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 3
    • 21344469080 scopus 로고    scopus 로고
    • Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws
    • W. Allan, E. D. Williams , C. J. Kerawala, "Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws," Br. J. Oral Maxillofac. Surg. , 43: 314-319, 2005.
    • (2005) Br. J. Oral Maxillofac. Surg. , vol.43 , pp. 314-319
    • Allan, W.1    Williams, E.D.2    Kerawala, C.J.3
  • 4
    • 0343168054 scopus 로고    scopus 로고
    • Temperature effects in the drilling of human , bovine bone
    • M. T. Hillery , I. Shuaib, "Temperature effects in the drilling of human , bovine bone," J. Mater. Process. Technol. , 92-93: 302-308, 1999.
    • (1999) J. Mater. Process. Technol. , vol.92-93 , pp. 302-308
    • Hillery, M.T.1    Shuaib, I.2
  • 5
    • 0028881831 scopus 로고
    • Measurements of shaft speed while drilling through bone
    • M. B. Abouzgia , D. F. James, "Measurements of shaft speed while drilling through bone," J. OralMaxillofac. Surg. ,53: 1308-1315, 1995.
    • (1995) J. OralMaxillofac. Surg. , vol.53 , pp. 1308-1315
    • Abouzgia, M.B.1    James, D.F.2
  • 6
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • L. S. Matthews , C. Hirsch, "Temperatures measured in human cortical bone when drilling," J. Bone Joint Surg. Am. , 54: 297-308, 1972.
    • (1972) J. Bone Joint Surg. Am. , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 7
    • 0034446654 scopus 로고    scopus 로고
    • The effects of drilling force on cortical temperatures , their duration: an in vitro study
    • K. N. Bachus, M. T. Rondina , D. T. Hutchinson, "The effects of drilling force on cortical temperatures , their duration: an in vitro study," Med. Eng. Phys. , 22: 685-691, 2000.
    • (2000) Med. Eng. Phys. , vol.22 , pp. 685-691
    • Bachus, K.N.1    Rondina, M.T.2    Hutchinson, D.T.3
  • 9
    • 0038374248 scopus 로고    scopus 로고
    • Drilling in bone: modeling heat generation , temperature distribution
    • S. R. H. Davidson , D. F. James, "Drilling in bone: modeling heat generation , temperature distribution," J. Biomech. Eng. , 125: 305-314, 2003.
    • (2003) J. Biomech. Eng. , vol.125 , pp. 305-314
    • Davidson, S.R.H.1    James, D.F.2
  • 10
    • 0001151301 scopus 로고    scopus 로고
    • Finite element modeling of burr formation process in drilling 304 stainless steel
    • Y. B. Guo , D. A. Dornfeld, "Finite element modeling of burr formation process in drilling 304 stainless steel," J. Manuf. Sci. Eng.-Trans. ASME, 122: 612-619, 2000.
    • (2000) J. Manuf. Sci. Eng.-Trans. ASME , vol.122 , pp. 612-619
    • Guo, Y.B.1    Dornfeld, D.A.2
  • 11
    • 84883771567 scopus 로고    scopus 로고
    • Worldwide: ADivision of Pacific Research Laboratories
    • Sawbones, Inc. Available at
    • Sawbones. Worldwide: ADivision of Pacific Research Laboratories, Inc. Available at http://www. sawbones.com/
  • 12
    • 0031973823 scopus 로고    scopus 로고
    • Changes in the stiffness, strength, , toughness ofhumancorticalbonewithage
    • P.Zioupos and J.D.Currey, "Changes in the stiffness, strength, and toughness of human cortical bone with age," Bone, 22: 57-66, 1998.
    • (1998) Bone , vol.22 , pp. 57-66
    • Zioupos, P.1    Currey, J.D.2
  • 13
    • 0021880663 scopus 로고
    • The mechanical behaviour of cancellous bone
    • L. J. Gibson, "The mechanical behaviour of cancellous bone," J. Biomech., 18: 317-328, 1985.
    • (1985) J. Biomech. , vol.18 , pp. 317-328
    • Gibson, L.J.1
  • 14
    • 0016170096 scopus 로고
    • The mechanical properties of corticalbone
    • D. T. Reilly , A. H. Burstein, "The mechanical properties of corticalbone,"J.BoneJointSurg.-Am.Vol.,56:1001-1022, 1974.
    • (1974) J.BoneJointSurg.-Am.Vol. , vol.56 , pp. 1001-1022
    • Reilly, D.T.1    Burstein, A.H.2
  • 15
    • 84883808606 scopus 로고    scopus 로고
    • SimuliaCorp,Systemes D,ABAQUS/St, ardUser'sManual, RI, UAS: Providence
    • SimuliaCorp,Systemes D,ABAQUS/St, ardUser'sManual, RI, UAS: Providence, 2008.
    • (2008)
  • 16
    • 2942635731 scopus 로고    scopus 로고
    • Stimulatingeffectofimplantloadingonsurrounding bone. Comparison of three numerical models , validation by in vivo data
    • A. Mellal, H. W. Wiskot, J. Botsis, S. S. Scherrer and U. C.Belser, "Stimulating effect of implant loading on surrounding bone.Comparison of three numerical models and validation by in vivo data," Clin.Oral Implants Res., 15: 239-248, 2004.
    • (2004) Clin. Oral Implants Res. , vol.15 , pp. 239-248
    • Mellal, A.1    Wiskot, H.W.2    Botsis, J.3    Scherrer, S.S.4    Belser, U.C.5
  • 17
    • 0018506498 scopus 로고
    • Three-point iterationsderived exponential curve fitting
    • C. J. F. Ridders, "Three-point iterationsderived exponential curve fitting," IEEE Trans. Circuits Syst., 26: 669-670, 1979.
    • (1979) IEEE Trans. Circuits Syst. , vol.26 , pp. 669-670
    • Ridders, C.J.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.