-
1
-
-
0040138724
-
Radiological use of fast protons
-
R. Wilson, " Radiological use of fast protons.," Radiology 47, 487-491 (1946).
-
(1946)
Radiology
, vol.47
, pp. 487-491
-
-
Wilson, R.1
-
2
-
-
0022493022
-
Proton beam penumbra: Effects of separation between patient and beam modifying device
-
10.1118/1.595974
-
M. M. Urie, J. M. Sisterson, A. M. Koehler, M. Goitein, and J. Zoesman, " Proton beam penumbra: Effects of separation between patient and beam modifying device.," Med. Phys. 13, 734-741 (1986). 10.1118/1.595974
-
(1986)
Med. Phys.
, vol.13
, pp. 734-741
-
-
Urie, M.M.1
Sisterson, J.M.2
Koehler, A.M.3
Goitein, M.4
Zoesman, J.5
-
3
-
-
80855139799
-
Multileaf collimators, air gap, lateral penumbra, and range compensation in proton radiotherapy
-
10.1118/1.3653297
-
B. Gottschalk, " Multileaf collimators, air gap, lateral penumbra, and range compensation in proton radiotherapy.," Med. Phys. 38, i-ii (2011). 10.1118/1.3653297
-
(2011)
Med. Phys.
, vol.38
-
-
Gottschalk, B.1
-
4
-
-
0030825076
-
A model for the lateral penumbra in water of a 200-MeV proton beam devoted to clinical applications
-
10.1118/1.597967
-
R. Oozeer, A. Mazal, J. Rosenwald, R. Belshi, C. Nauraye, R. Ferrand, and S. Biensan, " A model for the lateral penumbra in water of a 200-MeV proton beam devoted to clinical applications.," Med. Phys. 24, 1599-1604 (1997). 10.1118/1.597967
-
(1997)
Med. Phys.
, vol.24
, pp. 1599-1604
-
-
Oozeer, R.1
Mazal, A.2
Rosenwald, J.3
Belshi, R.4
Nauraye, C.5
Ferrand, R.6
Biensan, S.7
-
5
-
-
41049094248
-
Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy
-
10.1088/0031-9155/53/6/016
-
S. Safai, T. Bortfeld, and M. Engelsman, " Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy.," Phys. Med. Biol. 53, 1729-1750 (2008). 10.1088/0031-9155/53/6/016
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 1729-1750
-
-
Safai, S.1
Bortfeld, T.2
Engelsman, M.3
-
6
-
-
79953652367
-
Commissioning of output factors for uniform scanning proton beams
-
10.1118/1.3569581
-
Y. Zheng, E. Ramirez, A. Mascia, X. Ding, B. Okoth, O. Zeidan, W. Hsi, B. Harris, A. N. Schreuder, and S. Keole, " Commissioning of output factors for uniform scanning proton beams.," Med. Phys. 38, 2299-2306 (2011). 10.1118/1.3569581
-
(2011)
Med. Phys.
, vol.38
, pp. 2299-2306
-
-
Zheng, Y.1
Ramirez, E.2
Mascia, A.3
Ding, X.4
Okoth, B.5
Zeidan, O.6
Hsi, W.7
Harris, B.8
Schreuder, A.N.9
Keole, S.10
-
7
-
-
84863527960
-
Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams
-
10.1118/1.4718685
-
Y. Zheng, Y. Liu, O. Zeidan, A. Schreuder, and S. Keole, " Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams.," Med. Phys. 39, 3484-3492 (2012). 10.1118/1.4718685
-
(2012)
Med. Phys.
, vol.39
, pp. 3484-3492
-
-
Zheng, Y.1
Liu, Y.2
Zeidan, O.3
Schreuder, A.4
Keole, S.5
-
8
-
-
0003680967
-
-
IAEA Technical Report Series No 398 (IAEA, Vienna).
-
P. Andreo, D. T. Burns, K. Hohlfeld, M. S. Huq, T. Kanai, F. Laitano, V. G. Smith, and S. Vynckier, " Absorbed dose determination in external beam radiotherapy: an international Code of Practice for dosimetry based on standards of absorbed dose to water.," IAEA Technical Report Series No 398 (IAEA, Vienna, 2000).
-
(2000)
Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water
-
-
Andreo, P.1
Burns, D.T.2
Hohlfeld, K.3
Huq, M.S.4
Kanai, T.5
Laitano, F.6
Smith, V.G.7
Vynckier, S.8
-
9
-
-
0029902095
-
A pencil beam algorithm for proton dose calculations
-
10.1088/0031-9155/41/8/005
-
L. Hong, M. Goitein, M. Bucciolini, R. Comiskey, B. Gottschalk, S. Rosenthal, C. Serago, and M. Urie, " A pencil beam algorithm for proton dose calculations.," Phys. Med. Biol. 41, 1305-1330 (1996). 10.1088/0031-9155/41/8/005
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 1305-1330
-
-
Hong, L.1
Goitein, M.2
Bucciolini, M.3
Comiskey, R.4
Gottschalk, B.5
Rosenthal, S.6
Serago, C.7
Urie, M.8
-
10
-
-
0019523286
-
Electron beam dose calculations
-
10.1088/0031-9155/26/3/008
-
K. Hogstrom and M. Mills, " Electron beam dose calculations.," Phys. Med. Biol. 26, 445-459 (1981). 10.1088/0031-9155/26/3/008
-
(1981)
Phys. Med. Biol.
, vol.26
, pp. 445-459
-
-
Hogstrom, K.1
Mills, M.2
-
11
-
-
0034975820
-
Experimental determination and verification of the parameters used in a proton pencil beam algorithm
-
10.1118/1.1376445
-
H. Szymanowski, A. Mazal, C. Nauraye, S. Biensan, R. Ferrand, M. C. Murillo, S. Caneva, G. Gaboriaud, and J. C. Rosenwald, " Experimental determination and verification of the parameters used in a proton pencil beam algorithm.," Med. Phys. 28, 975-987 (2001). 10.1118/1.1376445
-
(2001)
Med. Phys.
, vol.28
, pp. 975-987
-
-
Szymanowski, H.1
Mazal, A.2
Nauraye, C.3
Biensan, S.4
Ferrand, R.5
Murillo, M.C.6
Caneva, S.7
Gaboriaud, G.8
Rosenwald, J.C.9
-
12
-
-
84883774453
-
-
PPTC Internal Report.
-
B. Harris, A. Mascia, Y. Zheng, X. Ding, B. Okoth, R. Jesseph, A. Kapur, A. Wagner, and N. Schreuder, " ProCure Proton Treatment Center Commissioning Report: IBA Proton Therapy Center to be used in conjunction with the Elekta XiO Treatment Planning System.," PPTC Internal Report, 2010.
-
(2010)
ProCure Proton Treatment Center Commissioning Report: IBA Proton Therapy Center to Be Used in Conjunction with the Elekta XiO Treatment Planning System
-
-
Harris, B.1
Mascia, A.2
Zheng, Y.3
Ding, X.4
Okoth, B.5
Jesseph, R.6
Kapur, A.7
Wagner, A.8
Schreuder, N.9
|