Volumn 24, Issue 9, 2013, Pages 1002-1007

Validation of accuracy of three-dimensional left atrial cartosound™ and CT image integration: Influence of respiratory phase and cardiac cycle

Author keywords

atrial fibrillation; CartoSound; catheter ablation; computed tomography; image integration; intracardiac echocardiography

Indexed keywords

ADULT; ARTICLE; BREATHING PATTERN; CARDIAC PATIENT; CLINICAL ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; HEART ATRIUM FIBRILLATION; HEART CYCLE; HEART LEFT ATRIUM; HUMAN; IMAGE ANALYSIS; MALE; PRIORITY JOURNAL; PULMONARY VEIN; PULMONARY VEIN ISOLATION; SINUS RHYTHM; THREE DIMENSIONAL IMAGING;

EID: 84883771293     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12170     Document Type: Article
Times cited : (23)

References (9)
  • 1
    • 33645279547 scopus 로고    scopus 로고
    • Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation
    • Kistler PM, Earley MJ, Harris S, Abrams D, Ellis S, Sporton SC, Schilling RJ,: Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 2006; 17: 341-348.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 341-348
    • Kistler, P.M.1    Earley, M.J.2    Harris, S.3    Abrams, D.4    Ellis, S.5    Sporton, S.C.6    Schilling, R.J.7
  • 2
    • 40149096070 scopus 로고    scopus 로고
    • Integration of three-dimensional left atrial magnetic resonance images into a real-time electroanatomic mapping system: Validation of a registration method
    • Bertaglia E, Brandolino G, Zoppo F, Zerbo F, Pascotto P,: Integration of three-dimensional left atrial magnetic resonance images into a real-time electroanatomic mapping system: Validation of a registration method. Pacing Clin Electrophysiol 2008; 31: 273-282.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 273-282
    • Bertaglia, E.1    Brandolino, G.2    Zoppo, F.3    Zerbo, F.4    Pascotto, P.5
  • 3
    • 84867097159 scopus 로고    scopus 로고
    • Impact of image integration on catheter ablation for atrial fibrillation using three-dimensional electroanatomic mapping: A meta-analysis
    • Liu SX, Zhang Y, Zhang XW,: Impact of image integration on catheter ablation for atrial fibrillation using three-dimensional electroanatomic mapping: A meta-analysis. Pacing Clin Electrophysiol 2012; 35: 1242-1247.
    • (2012) Pacing Clin Electrophysiol , vol.35 , pp. 1242-1247
    • Liu, S.X.1    Zhang, Y.2    Zhang, X.W.3
  • 4
    • 78650676745 scopus 로고    scopus 로고
    • Three-dimensional cardiac image integration of electroanatomical mapping of only left atrial posterior wall with CT image to guide circumferential pulmonary vein ablation
    • Itoh T, Sasaki S, Kimura M, Owada S, Horiuchi D, Sasaki K, Okumura K,: Three-dimensional cardiac image integration of electroanatomical mapping of only left atrial posterior wall with CT image to guide circumferential pulmonary vein ablation. J Interv Card Electrophysiol 2010; 29: 167-173.
    • (2010) J Interv Card Electrophysiol , vol.29 , pp. 167-173
    • Itoh, T.1    Sasaki, S.2    Kimura, M.3    Owada, S.4    Horiuchi, D.5    Sasaki, K.6    Okumura, K.7
  • 5
    • 33644652676 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation
    • Mikaelian BJ, Malchano ZJ, Neuzil P, Weichet J, Doshi SK, Ruskin JN, Reddy VY,: Images in cardiovascular medicine. Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation. Circulation 2005; 112: e35-36.
    • (2005) Circulation , vol.112
    • Mikaelian, B.J.1    Malchano, Z.J.2    Neuzil, P.3    Weichet, J.4    Doshi, S.K.5    Ruskin, J.N.6    Reddy, V.Y.7
  • 6
    • 53049085427 scopus 로고    scopus 로고
    • Three-dimensional ultrasound for image-guided mapping and intervention: Methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system
    • Okumura Y, Henz BD, Johnson SB, Bunch TJ, O'Brien CJ, Hodge DO, Altman A, Govari A, Packer DL,: Three-dimensional ultrasound for image-guided mapping and intervention: Methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system. Circ Arrhythm Electrophysiol 2008; 1: 110-119.
    • (2008) Circ Arrhythm Electrophysiol , vol.1 , pp. 110-119
    • Okumura, Y.1    Henz, B.D.2    Johnson, S.B.3    Bunch, T.J.4    O'Brien, C.J.5    Hodge, D.O.6    Altman, A.7    Govari, A.8    Packer, D.L.9
  • 7
    • 59649123670 scopus 로고    scopus 로고
    • New generation of electro-anatomic mapping: Full intracardiac ultrasound image integration
    • Suppl 3)
    • Packer DL, Johnson SB, Kolasa MW, Bunch TJ, Henz BD, Okumura Y,: New generation of electro-anatomic mapping: Full intracardiac ultrasound image integration. Europace 2008; 10(Suppl 3): iii35-41.
    • (2008) Europace , vol.10
    • Packer, D.L.1    Johnson, S.B.2    Kolasa, M.W.3    Bunch, T.J.4    Henz, B.D.5    Okumura, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.