메뉴 건너뛰기




Volumn 88, Issue , 2014, Pages 53-59

Evaluation of two modified quick, easy, cheap, effective, rugged and safe (QuEChERS) sample preparation methods for the analysis of baclofen and gabapentin in feeds by liquid chromatography tandem mass spectrometry

Author keywords

Baclofen; Feed; Gabapentin; LC MS MS; QuEChERS

Indexed keywords

ACETONITRILE; BACLOFEN; FORMIC ACID; GABAPENTIN; METHANOL;

EID: 84883744877     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2013.08.026     Document Type: Article
Times cited : (12)

References (19)
  • 1
    • 84883763540 scopus 로고    scopus 로고
    • Study on effect of several anti-heat-stress feed additives on pig growth performance ant their acting mechanisms
    • Zheng Q., Xue X., Chang J., Yin Q., Liu J., Wang X. Study on effect of several anti-heat-stress feed additives on pig growth performance ant their acting mechanisms. Acta Agric. Jiangxi 2010, 22(12):153-156.
    • (2010) Acta Agric. Jiangxi , vol.22 , Issue.12 , pp. 153-156
    • Zheng, Q.1    Xue, X.2    Chang, J.3    Yin, Q.4    Liu, J.5    Wang, X.6
  • 3
    • 0034327345 scopus 로고    scopus 로고
    • Intrathecal baclofen pump use for spasticity: a clinical survey
    • Stempien L., Tsai T. Intrathecal baclofen pump use for spasticity: a clinical survey. Am. J. Phys. Med. Rehabil. 2000, 79:536-541.
    • (2000) Am. J. Phys. Med. Rehabil. , vol.79 , pp. 536-541
    • Stempien, L.1    Tsai, T.2
  • 4
    • 0021714345 scopus 로고
    • Improved gas-liquid chromatographic method for the determination of baclofen in plasma and urine
    • Kochak G., Honc F. Improved gas-liquid chromatographic method for the determination of baclofen in plasma and urine. J. Chromatogr. 1984, 310:319-326.
    • (1984) J. Chromatogr. , vol.310 , pp. 319-326
    • Kochak, G.1    Honc, F.2
  • 5
    • 0023748345 scopus 로고
    • Determination of the S(+)- and R(-)-enantiomers of baclofen in plasma and urine by gas chromatography using a chiral fused-silica capillary column and an electron-capture detector
    • Sioufi A., Kaiser G., Leroux F., Dubois J.P. Determination of the S(+)- and R(-)-enantiomers of baclofen in plasma and urine by gas chromatography using a chiral fused-silica capillary column and an electron-capture detector. J. Chromatogr. 1988, 450:221-232.
    • (1988) J. Chromatogr. , vol.450 , pp. 221-232
    • Sioufi, A.1    Kaiser, G.2    Leroux, F.3    Dubois, J.P.4
  • 6
    • 33750364453 scopus 로고    scopus 로고
    • Determination of gabapentin in human plasma and urine by high-performance liquid chromatography with UV-vis detection
    • Sagirli O., Cetin S.M., Önal A. Determination of gabapentin in human plasma and urine by high-performance liquid chromatography with UV-vis detection. J. Pharm. Biomed. Anal. 2006, 42:618-624.
    • (2006) J. Pharm. Biomed. Anal. , vol.42 , pp. 618-624
    • Sagirli, O.1    Cetin, S.M.2    Önal, A.3
  • 7
    • 0037962244 scopus 로고    scopus 로고
    • ®) in bovine serum by liquid chromatography-mass spectrometry
    • ®) in bovine serum by liquid chromatography-mass spectrometry. J. Anal. Toxicol. 2003, 27:275-283.
    • (2003) J. Anal. Toxicol. , vol.27 , pp. 275-283
    • Miksa, I.R.1    Poppenga, R.H.2
  • 8
    • 84860431600 scopus 로고    scopus 로고
    • HPLC enantioresolution of (R,S)-baclofen using three newly synthesized dichloro-s-triazine reagents having amines and five others having amino acids as chiral auxiliaries
    • Bhushan R., Dixit S. HPLC enantioresolution of (R,S)-baclofen using three newly synthesized dichloro-s-triazine reagents having amines and five others having amino acids as chiral auxiliaries. Biomed. Chromatogr. 2012, 26:743-748.
    • (2012) Biomed. Chromatogr. , vol.26 , pp. 743-748
    • Bhushan, R.1    Dixit, S.2
  • 9
    • 70350596216 scopus 로고    scopus 로고
    • Simultaneous determination of R-(-)-, S-(+)-baclofen and impurity A by electrokinetic chromatography
    • Suntornsuk L., Ployngam S. Simultaneous determination of R-(-)-, S-(+)-baclofen and impurity A by electrokinetic chromatography. J. Pharm. Biomed. Anal. 2010, 51:541-548.
    • (2010) J. Pharm. Biomed. Anal. , vol.51 , pp. 541-548
    • Suntornsuk, L.1    Ployngam, S.2
  • 10
    • 0842287421 scopus 로고    scopus 로고
    • Sample preparation and determination of gabapentin in venous and capillary blood using liquid chromatography-tandem mass spectrometry
    • Carlsson K.C., Reubsaet J.L.E. Sample preparation and determination of gabapentin in venous and capillary blood using liquid chromatography-tandem mass spectrometry. J. Pharm. Biomed. Anal. 2004, 34:415-423.
    • (2004) J. Pharm. Biomed. Anal. , vol.34 , pp. 415-423
    • Carlsson, K.C.1    Reubsaet, J.L.E.2
  • 11
    • 0035110927 scopus 로고    scopus 로고
    • Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
    • Ifa D.R., Falci M., Moraes M.E., Bezerra F.A., Moraes M.O., de Nucci G. Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study. J. Mass Spectrom. 2001, 36:188-194.
    • (2001) J. Mass Spectrom. , vol.36 , pp. 188-194
    • Ifa, D.R.1    Falci, M.2    Moraes, M.E.3    Bezerra, F.A.4    Moraes, M.O.5    de Nucci, G.6
  • 12
    • 0037359650 scopus 로고    scopus 로고
    • Fast and easy multiresidue method employing acetonitrile extraction/partitioning and dispersive solid-phase extraction for the determination of pesticide residues in produce
    • Anastassiades M., Lehotay S.J., Štajnbaher D., Schenck F.J. Fast and easy multiresidue method employing acetonitrile extraction/partitioning and dispersive solid-phase extraction for the determination of pesticide residues in produce. J. AOAC Int. 2003, 86:412-431.
    • (2003) J. AOAC Int. , vol.86 , pp. 412-431
    • Anastassiades, M.1    Lehotay, S.J.2    Štajnbaher, D.3    Schenck, F.J.4
  • 13
    • 0013285756 scopus 로고    scopus 로고
    • COMMISSION DECISION of 14 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results
    • European Commission, Commission Decision 2002/657/EC
    • European Commission, Commission Decision 2002/657/EC COMMISSION DECISION of 14 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results. Off. J. Eur. Commun. 2002, L221:8-36.
    • (2002) Off. J. Eur. Commun. , vol.L221 , pp. 8-36
  • 14
    • 84883769821 scopus 로고    scopus 로고
    • European Commission, Method validation and quality control procedures for pesticide residues analysis in food and feed, Document No SANCO/12495/2011, 1.01.12.
    • European Commission, Method validation and quality control procedures for pesticide residues analysis in food and feed, Document No SANCO/12495/2011, 1.01.12.
  • 15
    • 84866991747 scopus 로고    scopus 로고
    • 2 in corn using a modified QuEChERS method and LC-MS-MS
    • 2 in corn using a modified QuEChERS method and LC-MS-MS. Chromatographia 2012, 75:1075-1080.
    • (2012) Chromatographia , vol.75 , pp. 1075-1080
    • Yang, Q.F.1    Wu, Y.L.2
  • 16
  • 17
    • 17644431447 scopus 로고    scopus 로고
    • Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
    • Hajslová J., Zrostlíková J. Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices. J. Chromatogr. A 2003, 1000:181-197.
    • (2003) J. Chromatogr. A , vol.1000 , pp. 181-197
    • Hajslová, J.1    Zrostlíková, J.2
  • 18
    • 79959349764 scopus 로고    scopus 로고
    • Multi-mycotoxin analysis in eggs using a QuEChERS-based extraction procedure and ultra-high-pressure liquid chromatography coupled to triple quadrupole mass spectrometry
    • Frenich A.G., Romero-González R., Gómez-Pérez M.L., Martinez Vidal J.L. Multi-mycotoxin analysis in eggs using a QuEChERS-based extraction procedure and ultra-high-pressure liquid chromatography coupled to triple quadrupole mass spectrometry. J. Chromatogr. A 2011, 1218:4349-4356.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 4349-4356
    • Frenich, A.G.1    Romero-González, R.2    Gómez-Pérez, M.L.3    Martinez Vidal, J.L.4
  • 19
    • 84883817031 scopus 로고    scopus 로고
    • Determination of baclofen in feeds by LC-MS/MS
    • Huang S., Li D., Gu X., Zhang W. Determination of baclofen in feeds by LC-MS/MS. Feed Res. 2013, 36(5):62-65.
    • (2013) Feed Res. , vol.36 , Issue.5 , pp. 62-65
    • Huang, S.1    Li, D.2    Gu, X.3    Zhang, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.