메뉴 건너뛰기




Volumn 111, Issue , 2013, Pages 663-673

Highly-selective determination of carcinogenic derivative of propranolol by using a carbon paste electrode incorporated with nano-sized propranolol-imprinted polymer

Author keywords

Carbon paste; Imprinted polymer; N nitrosopropranolol; Nano sized; Voltammetric sensor

Indexed keywords

CHEMICAL DETECTION; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; EXTRACTION; NANOPARTICLES; NANOSENSORS; POLYMERIZATION; VOLTAMMETRY;

EID: 84883692744     PISSN: 00134686     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.electacta.2013.08.075     Document Type: Article
Times cited : (30)

References (29)
  • 1
    • 0016611279 scopus 로고
    • Formation of N-nitroso compounds: Chemistry, kinetics and in vivooccurrence
    • S.S. Mirvish, Formation of N-nitroso compounds: chemistry, kinetics and in vivooccurrence, Toxicol. Appl. Pharmacol. 31 (1975) 325.
    • (1975) Toxicol. Appl. Pharmacol. , vol.31 , pp. 325
    • Mirvish, S.S.1
  • 2
    • 0020955338 scopus 로고
    • The etiology of gastric cancer intragastric nitrosoamide formationand other theories
    • S.S. Mirvish, The etiology of gastric cancer intragastric nitrosoamide formationand other theories, J. Natl. Cancer Inst. 71 (1983) 629.
    • (1983) J. Natl. Cancer Inst. , vol.71 , pp. 629
    • Mirvish, S.S.1
  • 3
    • 0028136521 scopus 로고
    • Low clastogenic activityin vivo of the N-nitrosoderivative of 5-badrenergic-blocking drugs proved tobe potent genotoxins in vitro
    • A. Martelli, A. Allavena, E. Sottofattori, G. Brambilla, Low clastogenic activityin vivo of the N-nitrosoderivative of 5-badrenergic-blocking drugs proved tobe potent genotoxins in vitro, Toxicol. Lett. 73 (1994) 185.
    • (1994) Toxicol. Lett. , vol.73 , pp. 185
    • Martelli, A.1    Allavena, A.2    Sottofattori, E.3    Brambilla, G.4
  • 4
    • 0025778705 scopus 로고
    • Endogenous N-nitrosation in man assessed by measurement of apparent total N-nitrosocompounds in faeces
    • I.R. Rowland, T. Granli, O.C. Bockman, P.E. Key, R.C. Massy, Endogenous N-nitrosation in man assessed by measurement of apparent total N-nitrosocompounds in faeces, Carcinogenesis 12 (1991) 1395.
    • (1991) Carcinogenesis , vol.12 , pp. 1395
    • Rowland, I.R.1    Granli, T.2    Bockman, O.C.3    Key, P.E.4    Massy, R.C.5
  • 5
    • 0022346612 scopus 로고
    • Genotoxic effects of drug/nitrite interaction products: Evidencefor the need of risk assessment
    • G. Brambilla, Genotoxic effects of drug/nitrite interaction products: evidencefor the need of risk assessment, Pharmacol. Res. Commun. 17 (1985) 307.
    • (1985) Pharmacol. Res. Commun. , vol.17 , pp. 307
    • Brambilla, G.1
  • 6
    • 0030898859 scopus 로고    scopus 로고
    • High performance liquid chro-matographic study of formation of N-nitrosopropranolol in simulated gastricjuice
    • E. Sottofattori, M. Anzaldi, A. Balbi, A. Martelli, High performance liquid chro-matographic study of formation of N-nitrosopropranolol in simulated gastricjuice, Farmaco 52 (1997) 123.
    • (1997) Farmaco , vol.52 , pp. 123
    • Sottofattori, E.1    Anzaldi, M.2    Balbi, A.3    Martelli, A.4
  • 7
    • 0025811411 scopus 로고
    • Formation of N-nitrosoderivatives of six β-adrenergic blocking agents and theirgenotoxic effects in rat and human hepatocytes
    • L. Robianno, A. Martelli, A. Allavena, M. Mazxei, G.M. Gazzaniga, G. Brambilla,Formation of N-nitrosoderivatives of six β-adrenergic blocking agents and theirgenotoxic effects in rat and human hepatocytes, Cancer Res. 51 (1991) 2273.
    • (1991) Cancer Res. , vol.51 , pp. 2273
    • Robianno, L.1    Martelli, A.2    Allavena, A.3    Mazxei, M.4    Gazzaniga, G.M.5    Brambilla, G.6
  • 8
    • 0032749359 scopus 로고    scopus 로고
    • Voltammetric determi-nation of N-nitrosoderivatives of atenolol and propranolol in simulated gastricjuice
    • F. Belal, O.A. Al-Deeb, A.A. Al-Majed, E.A.R.G. Kariem, Voltammetric determi-nation of N-nitrosoderivatives of atenolol and propranolol in simulated gastricjuice, Farmaco 54 (1999) 700.
    • (1999) Farmaco , vol.54 , pp. 700
    • Belal, F.1    Al-Deeb, O.A.2    Al-Majed, A.A.3    Kariem, E.A.R.G.4
  • 9
    • 46149098310 scopus 로고    scopus 로고
    • Development of a molecularly imprinted polymer for pyridoxineusing an ion-pair as template
    • T. Alizadeh, Development of a molecularly imprinted polymer for pyridoxineusing an ion-pair as template, Anal. Chim. Acta 623 (2008) 101.
    • (2008) Anal. Chim. Acta , vol.623 , pp. 101
    • Alizadeh, T.1
  • 10
    • 77955555013 scopus 로고    scopus 로고
    • Comparison of different methodologies for integration of molec-ularly imprinted polymer and electrochemical transducer in order to developa paraoxon voltammetric sensor
    • T. Alizadeh, Comparison of different methodologies for integration of molec-ularly imprinted polymer and electrochemical transducer in order to developa paraoxon voltammetric sensor, Thin Solid Films 518 (2010) 6099.
    • (2010) Thin Solid Films , vol.518 , pp. 6099
    • Alizadeh, T.1
  • 11
    • 80052964047 scopus 로고    scopus 로고
    • Selective determination of chlor-amphenicol at trace level in milk samples by the electrode modified withmolecularly imprinted polymer
    • T. Alizadeh, M.R. Ganjali, M. Zare, P. Norouzi, Selective determination of chlor-amphenicol at trace level in milk samples by the electrode modified withmolecularly imprinted polymer, Food Chem. 130 (2012) 1108.
    • (2012) Food Chem. , vol.130 , pp. 1108
    • Alizadeh, T.1    Ganjali, M.R.2    Zare, M.3    Norouzi, P.4
  • 12
    • 79956098864 scopus 로고    scopus 로고
    • 2+imprinted polymer andits application as the chemical interface of an electrochemical sensor for toxiclead determination in different real samples
    • T. Alizadeh, S. Amjadi, Preparation of nano-sized Pb2+imprinted polymer andits application as the chemical interface of an electrochemical sensor for toxiclead determination in different real samples, J. Hazard. Mater. 190 (2011)451.
    • (2011) J. Hazard. Mater. , vol.190 , pp. 451
    • Alizadeh, T.1    Amjadi, S.2
  • 13
    • 74549179801 scopus 로고    scopus 로고
    • Development of a voltammetricsensor based on a molecularly imprinted polymer (MIP) for caffeine measure-ment
    • T. Alizadeha, M.R. Ganjali, M. Zare, P. Norouzi, Development of a voltammetricsensor based on a molecularly imprinted polymer (MIP) for caffeine measure-ment, Electrochim. Acta 55 (2010) 1568.
    • (2010) Electrochim. Acta , vol.55 , pp. 1568
    • Alizadeha, T.1    Ganjali, M.R.2    Zare, M.3    Norouzi, P.4
  • 14
    • 71849098047 scopus 로고    scopus 로고
    • A new molecularlyimprinted polymer (MIP) -based electrochemical sensor for monitoring 2, 4,6-trinitrotoluene (TNT) in natural waters and soil samples
    • T. Alizadeha, M. Zare, M.R. Ganjali, P. Norouzi, B. Tavana, A new molecularlyimprinted polymer (MIP)-based electrochemical sensor for monitoring 2,4,6-trinitrotoluene (TNT) in natural waters and soil samples, Biosens. Bioelectron.25 (2010) 1166.
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 1166
    • Alizadeha, T.1    Zare, M.2    Ganjali, M.R.3    Norouzi, P.4    Tavana, B.5
  • 15
    • 84864379359 scopus 로고    scopus 로고
    • Electrochemical sen-sor based on gold nanoparticles fabricated molecularly imprinted polymerfilm at chitosan-platinum nanoparticles/graphene- gold nanoparticles doublenanocomposites modified electrode for detection of erythromycin
    • W. Lian, S. Liu, J. Yu, X. Xing, J. Li, M. Cui, J. Huang, Electrochemical sen-sor based on gold nanoparticles fabricated molecularly imprinted polymerfilm at chitosan-platinum nanoparticles/graphene-gold nanoparticles doublenanocomposites modified electrode for detection of erythromycin, Biosens.Bioelectron. 38 (2012) 163.
    • (2012) Biosens.Bioelectron. , vol.38 , pp. 163
    • Lian, W.1    Liu, S.2    Yu, J.3    Xing, X.4    Li, J.5    Cui, M.6    Huang, J.7
  • 16
    • 79961128811 scopus 로고    scopus 로고
    • Acetylsalicylic acid electrochemicalsensor based on PATP-AuNPs modified molecularly imprinted polymer film
    • Z. Wang, H. Li, J. Chen, Z. Xue, B. Wu, X. Lu, Acetylsalicylic acid electrochemicalsensor based on PATP-AuNPs modified molecularly imprinted polymer film,Talanta 85 (2011) 1672.
    • (2011) Talanta , vol.85 , pp. 1672
    • Wang, Z.1    Li, H.2    Chen, J.3    Xue, Z.4    Wu, B.5    Lu, X.6
  • 17
    • 84864779004 scopus 로고    scopus 로고
    • Emodin voltammetric sen-sor based on molecularly imprinted polymer membrane-modified electrodeusing a multiple hydrogen bonds strategy
    • Z. Yu, J. Yang, J. Zhong, S. Wu, Z. Xu, Y. Tang, Emodin voltammetric sen-sor based on molecularly imprinted polymer membrane-modified electrodeusing a multiple hydrogen bonds strategy, J. Appl. Polym. Sci. 126 (2012)1344.
    • (2012) J. Appl. Polym. Sci. , vol.126 , pp. 1344
    • Yu, Z.1    Yang, J.2    Zhong, J.3    Wu, S.4    Xu, Z.5    Tang, Y.6
  • 18
    • 79952452697 scopus 로고    scopus 로고
    • A hemin-based molecularly imprinted polymer (MIP) grafted onto a glassycarbon electrode as a selective sensor for 4-aminophenol amperometric
    • J.R.M. Neto, W.J.R. Santos, P.R. Lima, S.M.C.N. Tanaka, A.A. Tanaka, L.T. Kub-ota, A hemin-based molecularly imprinted polymer (MIP) grafted onto a glassycarbon electrode as a selective sensor for 4-aminophenol amperometric, Sens.Actuators B 152 (2011) 220.
    • (2011) Sens.Actuators B , vol.152 , pp. 220
    • Neto, J.R.M.1    Santos, W.J.R.2    Lima, P.R.3    Tanaka, S.M.C.N.4    Tanaka, A.A.5    Kub-Ota, L.T.6
  • 20
    • 67349283042 scopus 로고    scopus 로고
    • Electrochemical sensor for uric acid basedon a molecularly imprinted polymer brush grafted to tetraethoxysilane derivedsol-gel thin film graphite electrode
    • A.K. Patel, P.S. Sharma, B.B. Prasad, Electrochemical sensor for uric acid basedon a molecularly imprinted polymer brush grafted to tetraethoxysilane derivedsol-gel thin film graphite electrode, Mater. Sci. Eng. C 29 (2009) 1545.
    • (2009) Mater. Sci. Eng. C , vol.29 , pp. 1545
    • Patel, A.K.1    Sharma, P.S.2    Prasad, B.B.3
  • 21
    • 58149193418 scopus 로고    scopus 로고
    • Imprinting of molecular recognition sites onnanostructures and its applications in chemosensors
    • G. Guan, B. Liu, Z. Wang, Z. Zhang, Imprinting of molecular recognition sites onnanostructures and its applications in chemosensors, Sensors 8 (2008) 8291.
    • (2008) Sensors , vol.8 , pp. 8291
    • Guan, G.1    Liu, B.2    Wang, Z.3    Zhang, Z.4
  • 22
    • 34347206289 scopus 로고    scopus 로고
    • A surface functionalmonomer-directing strategy for highly dense imprinting of TNT at surface ofsilica nanoparticles
    • D. Gao, Z. Zhang, M. Wu, C. Xie, G. Guan, D. Wang, A surface functionalmonomer-directing strategy for highly dense imprinting of TNT at surface ofsilica nanoparticles, J. Am. Chem. Soc. 129 (2007) 7859.
    • (2007) J. Am. Chem. Soc. , vol.129 , pp. 7859
    • Gao, D.1    Zhang, Z.2    Wu, M.3    Xie, C.4    Guan, G.5    Wang, D.6
  • 23
    • 33845523106 scopus 로고    scopus 로고
    • Surface molecular self-assembly strategy for TNT imprinting of polymer nanowire/nanotube arrays
    • Ch. Xie, Z. Zhang, D. Wang, G. Guan, D. Gao, J. Liu, Surface molecular self-assembly strategy for TNT imprinting of polymer nanowire/nanotube arrays,Anal. Chem. 78 (2006) 8339.
    • (2006) Anal. Chem. , vol.78 , pp. 8339
    • Xie, Ch.1    Zhang, Z.2    Wang, D.3    Guan, G.4    Gao, D.5    Liu, J.6
  • 24
    • 84865076672 scopus 로고    scopus 로고
    • Synthesis and application of differentnano-sized imprinted polymers for the preparation of promethazine mem-brane electrodes and comparison of their efficiencies
    • T. Alizadeh, M.R. Ganjali, M. Akhoundian, Synthesis and application of differentnano-sized imprinted polymers for the preparation of promethazine mem-brane electrodes and comparison of their efficiencies, Int. J. Electrochem. Sci. 7(2012) 7655.
    • (2012) Int. J. Electrochem. Sci. , vol.7 , pp. 7655
    • Alizadeh, T.1    Ganjali, M.R.2    Akhoundian, M.3
  • 25
    • 84864651301 scopus 로고    scopus 로고
    • Application of electrochemical impedance spectroscopy andconventional rebinding experiments for the investigation of recognition char-acteristic of bulky and nano-sized imprinted polymers
    • T. Alizadeh, Application of electrochemical impedance spectroscopy andconventional rebinding experiments for the investigation of recognition char-acteristic of bulky and nano-sized imprinted polymers, Mater. Chem. Phys. 135(2012) 1012.
    • (2012) Mater. Chem. Phys. , vol.135 , pp. 1012
    • Alizadeh, T.1
  • 26
    • 84858734895 scopus 로고    scopus 로고
    • Evaluation of the facilitated transport capabilitiesof nano- and micro-sized molecularly imprinted polymers (MIPs) in a bulkliquid membrane system
    • T. Alizadeh, N. Memarbashi, Evaluation of the facilitated transport capabilitiesof nano- and micro-sized molecularly imprinted polymers (MIPs) in a bulkliquid membrane system, Sep. Purif. Technol. 90 (2012) 83.
    • (2012) Sep. Purif. Technol. , vol.90 , pp. 83
    • Alizadeh, T.1    Memarbashi, N.2
  • 27
    • 0026378291 scopus 로고
    • Synthesis and HPLC assessmentof N-nitrosoderivatives from six β-adrenergic antagonists
    • M. Mazzel, E. Sottofatori, A. Balbi, L. Robbiano, Synthesis and HPLC assessmentof N-nitrosoderivatives from six β-adrenergic antagonists, Farmaco 46 (1991)1043-1049.
    • (1991) Farmaco , vol.46 , pp. 1043-1049
    • Mazzel, M.1    Sottofatori, E.2    Balbi, A.3    Robbiano, L.4
  • 28
    • 5444266856 scopus 로고
    • Rockville, USA Convention, Washington
    • United States Pharmacopoeia XXIII, Rockville, USA Convention, Washington,1995, p. 2053.
    • (1995) United States Pharmacopoeia XXIII , pp. 2053
  • 29
    • 0034801534 scopus 로고    scopus 로고
    • Target analogueimprinted polymers with affinity for folic acid and related compounds
    • M. Quaglia, K. Chenon, A.J. Hall, E.D. Lorenzi, B. Sellergren, Target analogueimprinted polymers with affinity for folic acid and related compounds, J. Am.Chem. Soc. 123 (2001) 2146.
    • (2001) J. Am.Chem. Soc. , vol.123 , pp. 2146
    • Quaglia, M.1    Chenon, K.2    Hall, A.J.3    Lorenzi, E.D.4    Sellergren, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.