메뉴 건너뛰기




Volumn 13, Issue , 2013, Pages

In emergently ventilated trauma patients, low end-tidal CO2 and low cardiac output are associated and correlate with hemodynamic instability, hemorrhage, abnormal pupils, and death

Author keywords

Capnography; Cardiac output; Trauma; Validation

Indexed keywords

ADULT; ARTICLE; BLEEDING; BRADYCARDIA; END TIDAL CARBON DIOXIDE TENSION; FORWARD HEART FAILURE; GLASGOW COMA SCALE; HEART ARREST; HUMAN; HYPOTENSION; INJURY; INJURY SCALE; MAJOR CLINICAL STUDY; MORTALITY; PUPIL DISEASE;

EID: 84883650191     PISSN: None     EISSN: 14712253     Source Type: Journal    
DOI: 10.1186/1471-2253-13-20     Document Type: Article
Times cited : (24)

References (19)
  • 1
    • 84864632978 scopus 로고    scopus 로고
    • Emergency department noninvasive (NICOM) cardiac outputs are associated with trauma activation, patient injury severity and host conditions and mortality
    • Dunham CM, Chirichella TJ, Gruber BS, Ferrari JP, Martin JA, Luchs BA, Hileman BM, Merrell R. Emergency department noninvasive (NICOM) cardiac outputs are associated with trauma activation, patient injury severity and host conditions and mortality. J Trauma Acute Care Surg 2012, 73(2):479-485.
    • (2012) J Trauma Acute Care Surg , vol.73 , Issue.2 , pp. 479-485
    • Dunham, C.M.1    Chirichella, T.J.2    Gruber, B.S.3    Ferrari, J.P.4    Martin, J.A.5    Luchs, B.A.6    Hileman, B.M.7    Merrell, R.8
  • 3
    • 0023544638 scopus 로고
    • End-tidal carbon dioxide as a noninvasive monitor of circulatory status during cardiopulmonary resuscitation: a preliminary clinical study
    • Lepilin MG, Vasilyev AV, Bildinov OA, Rostovtseva NA. End-tidal carbon dioxide as a noninvasive monitor of circulatory status during cardiopulmonary resuscitation: a preliminary clinical study. Crit Care Med 1987, 15(10):958-959.
    • (1987) Crit Care Med , vol.15 , Issue.10 , pp. 958-959
    • Lepilin, M.G.1    Vasilyev, A.V.2    Bildinov, O.A.3    Rostovtseva, N.A.4
  • 6
    • 0025027034 scopus 로고
    • Relationship between cardiac output and the end-tidal carbon dioxide tension
    • Ornato JP, Garnett AR, Glauser FL. Relationship between cardiac output and the end-tidal carbon dioxide tension. Ann Emerg Med 1990, 19(10):1104-1106.
    • (1990) Ann Emerg Med , vol.19 , Issue.10 , pp. 1104-1106
    • Ornato, J.P.1    Garnett, A.R.2    Glauser, F.L.3
  • 7
    • 0033866708 scopus 로고    scopus 로고
    • End-tidal carbon dioxide as a noninvasive indicator of cardiac index during circulatory shock
    • Jin X, Weil MH, Tang W, Povoas H, Pernat A, Xie J, Bisera J. End-tidal carbon dioxide as a noninvasive indicator of cardiac index during circulatory shock. Crit Care Med 2000, 28(7):2415-2419.
    • (2000) Crit Care Med , vol.28 , Issue.7 , pp. 2415-2419
    • Jin, X.1    Weil, M.H.2    Tang, W.3    Povoas, H.4    Pernat, A.5    Xie, J.6    Bisera, J.7
  • 13
    • 0036779882 scopus 로고    scopus 로고
    • End-tidal CO2-derived values during emergency trauma surgery correlated with outcome: a prospective study
    • Tyburski JG, Collinge JD, Wilson RF, Carlin AM, Albaran RG, Steffes CP. End-tidal CO2-derived values during emergency trauma surgery correlated with outcome: a prospective study. J Trauma 2002, 53(4):738-743.
    • (2002) J Trauma , vol.53 , Issue.4 , pp. 738-743
    • Tyburski, J.G.1    Collinge, J.D.2    Wilson, R.F.3    Carlin, A.M.4    Albaran, R.G.5    Steffes, C.P.6
  • 14
    • 53349140933 scopus 로고    scopus 로고
    • Partial pressure of end-tidal carbon dioxide successful predicts cardiopulmonary resuscitation in the field: a prospective observational study
    • Kolar M, Krizmaric M, Klemen P, Grmec S. Partial pressure of end-tidal carbon dioxide successful predicts cardiopulmonary resuscitation in the field: a prospective observational study. Crit Care 2008, 12(5):R115.
    • (2008) Crit Care , vol.12 , Issue.5
    • Kolar, M.1    Krizmaric, M.2    Klemen, P.3    Grmec, S.4
  • 15
    • 33747585345 scopus 로고    scopus 로고
    • The effect of a protocol of aggressive donor management: implications for the national organ donor shortage
    • discussion 433-425
    • Salim A, Martin M, Brown C, Rhee P, Demetriades D, Belzberg H. The effect of a protocol of aggressive donor management: implications for the national organ donor shortage. J Trauma 2006, 61(2):429-433. discussion 433-425.
    • (2006) J Trauma , vol.61 , Issue.2 , pp. 429-433
    • Salim, A.1    Martin, M.2    Brown, C.3    Rhee, P.4    Demetriades, D.5    Belzberg, H.6
  • 16
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature
    • Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009, 37(9):2642-2647.
    • (2009) Crit Care Med , vol.37 , Issue.9 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 17
    • 77953533489 scopus 로고    scopus 로고
    • Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study
    • Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, Pradl R, Stepan M. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care 2010, 14(3):R118.
    • (2010) Crit Care , vol.14 , Issue.3
    • Benes, J.1    Chytra, I.2    Altmann, P.3    Hluchy, M.4    Kasal, E.5    Svitak, R.6    Pradl, R.7    Stepan, M.8
  • 18
    • 84872137892 scopus 로고    scopus 로고
    • Noninvasive cardiac output monitors: a state-of the-art review
    • Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Surg 2013, 27(1):121-134.
    • (2013) J Cardiothorac Surg , vol.27 , Issue.1 , pp. 121-134
    • Marik, P.E.1
  • 19
    • 78650833522 scopus 로고    scopus 로고
    • Cardiac output monitoring: is there a gold standard and how do the newer technologies compare?
    • Pugsley J, Lerner AB. Cardiac output monitoring: is there a gold standard and how do the newer technologies compare?. Semin Cardiothorac Vasc Anesth 2010, 14(4):274-282.
    • (2010) Semin Cardiothorac Vasc Anesth , vol.14 , Issue.4 , pp. 274-282
    • Pugsley, J.1    Lerner, A.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.