메뉴 건너뛰기




Volumn 8, Issue 9, 2013, Pages

Evaluation of the Impact of Alveolar Nitrogen Excretion on Indices Derived from Multiple Breath Nitrogen Washout

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ALVEOLAR NITROGEN EXCRETION; ARTICLE; CONCENTRATION (PARAMETERS); FUNCTIONAL RESIDUAL CAPACITY; LUNG ALVEOLUS; LUNG CLEARANCE; LUNG CLEARANCE INDEX; LUNG DEAD SPACE; LUNG FUNCTION; LUNG VENTILATION; MEASUREMENT ERROR; NITROGEN WASHOUT; RESPIRATORY TRACT PARAMETERS;

EID: 84883618618     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0073335     Document Type: Article
Times cited : (32)

References (25)
  • 1
    • 67349175293 scopus 로고    scopus 로고
    • Lung clearance index in the assessment of airways disease
    • Horsley A, (2009) Lung clearance index in the assessment of airways disease. Respir Med 103: 793-799.
    • (2009) Respir Med , vol.103 , pp. 793-799
    • Horsley, A.1
  • 2
    • 0346121620 scopus 로고    scopus 로고
    • Evaluation of ventilation maldistribution as an early indicator of lung disease in children with cystic fibrosis
    • Gustafsson PM, Aurora P, Lindblad A, (2003) Evaluation of ventilation maldistribution as an early indicator of lung disease in children with cystic fibrosis. Eur Respir J 22: 972-979.
    • (2003) Eur Respir J , vol.22 , pp. 972-979
    • Gustafsson, P.M.1    Aurora, P.2    Lindblad, A.3
  • 3
    • 9644259076 scopus 로고    scopus 로고
    • Multiple breath inert gas washout as a measure of ventilation distribution in children with cystic fibrosis
    • Aurora P, Gustafsson P, Bush A, Lindblad A, Oliver C, et al. (2004) Multiple breath inert gas washout as a measure of ventilation distribution in children with cystic fibrosis. Thorax 59: 1068-1073.
    • (2004) Thorax , vol.59 , pp. 1068-1073
    • Aurora, P.1    Gustafsson, P.2    Bush, A.3    Lindblad, A.4    Oliver, C.5
  • 4
    • 39049105720 scopus 로고    scopus 로고
    • Lung clearance index is a sensitive, repeatable and practical measure of airways disease in adults with cystic fibrosis
    • Horsley AR, Gustafsson PM, Macleod KA, Saunders C, Greening AP, et al. (2008) Lung clearance index is a sensitive, repeatable and practical measure of airways disease in adults with cystic fibrosis. Thorax 63: 135-140.
    • (2008) Thorax , vol.63 , pp. 135-140
    • Horsley, A.R.1    Gustafsson, P.M.2    Macleod, K.A.3    Saunders, C.4    Greening, A.P.5
  • 5
    • 77951988740 scopus 로고    scopus 로고
    • Hypertonic saline improves the LCI in paediatric patients with CF with normal lung function
    • Amin R, Subbarao P, Jabar A, Balkovec S, Jensen R, et al. (2010) Hypertonic saline improves the LCI in paediatric patients with CF with normal lung function. Thorax 65: 379-383.
    • (2010) Thorax , vol.65 , pp. 379-383
    • Amin, R.1    Subbarao, P.2    Jabar, A.3    Balkovec, S.4    Jensen, R.5
  • 6
    • 79953287790 scopus 로고    scopus 로고
    • The effect of dornase alfa on ventilation inhomogeneity in patients with cystic fibrosis
    • Amin R, Subbarao P, Lou W, Jabar A, Balkovec S, et al. (2011) The effect of dornase alfa on ventilation inhomogeneity in patients with cystic fibrosis. Eur Respir J 37: 806-812.
    • (2011) Eur Respir J , vol.37 , pp. 806-812
    • Amin, R.1    Subbarao, P.2    Lou, W.3    Jabar, A.4    Balkovec, S.5
  • 7
    • 23644454805 scopus 로고    scopus 로고
    • Gas mixing efficiency from birth to adulthood measured by multiple-breath washout
    • Aurora P, Kozlowska W, Stocks J, (2005) Gas mixing efficiency from birth to adulthood measured by multiple-breath washout. Respir Physiol Neurobiol 148: 125-139.
    • (2005) Respir Physiol Neurobiol , vol.148 , pp. 125-139
    • Aurora, P.1    Kozlowska, W.2    Stocks, J.3
  • 8
    • 84875266201 scopus 로고    scopus 로고
    • Consensus statement for inert gas washout measurement using multiple and single breath tests
    • Robinson P, Latzin P, Verbanck S, Hall GL, Horsley A, et al. (2013) Consensus statement for inert gas washout measurement using multiple and single breath tests. European Respiratory Journal 41(3): 507-522.
    • (2013) European Respiratory Journal , vol.41 , Issue.3 , pp. 507-522
    • Robinson, P.1    Latzin, P.2    Verbanck, S.3    Hall, G.L.4    Horsley, A.5
  • 9
    • 0037975652 scopus 로고    scopus 로고
    • Peripheral airway involvement in asthma assessed by single-breath SF6 and He washout
    • Gustafsson PM, Ljungberg HK, Kjellman B, (2003) Peripheral airway involvement in asthma assessed by single-breath SF6 and He washout. Eur Respir J 21: 1033-1039.
    • (2003) Eur Respir J , vol.21 , pp. 1033-1039
    • Gustafsson, P.M.1    Ljungberg, H.K.2    Kjellman, B.3
  • 11
    • 0343081791 scopus 로고
    • Studies on the Intrapulmonary Mixture of Gases. I. Nitrogen Elimination from Blood and Body Tissues During High Oxygen Breathing
    • Darling RC, Cournand A, Mansfield JS, Richards DW, (1940) Studies on the Intrapulmonary Mixture of Gases. I. Nitrogen Elimination from Blood and Body Tissues During High Oxygen Breathing. J Clin Invest 19: 591-597.
    • (1940) J Clin Invest , vol.19 , pp. 591-597
    • Darling, R.C.1    Cournand, A.2    Mansfield, J.S.3    Richards, D.W.4
  • 12
    • 0001317123 scopus 로고
    • Nitrogen elimination during oxygen breathing
    • Lundin G (1953) Nitrogen elimination during oxygen breathing. Acta Physiol Scand Suppl 111: 130-143.
    • (1953) Acta Physiol Scand Suppl , vol.111 , pp. 130-143
    • Lundin, G.1
  • 13
    • 84858053994 scopus 로고    scopus 로고
    • Is the rate of whole-body nitrogen elimination influenced by exercise?
    • Pendergast DR, Senf C, Lundgren CE, (2012) Is the rate of whole-body nitrogen elimination influenced by exercise? Undersea Hyperb Med 39: 595-604.
    • (2012) Undersea Hyperb Med , vol.39 , pp. 595-604
    • Pendergast, D.R.1    Senf, C.2    Lundgren, C.E.3
  • 14
    • 0014470114 scopus 로고
    • Ventilatory efficiency, capacity and lung volumes in healthy children
    • Kjellman B, (1969) Ventilatory efficiency, capacity and lung volumes in healthy children. Scand J Clin Lab Invest 23: 19-29.
    • (1969) Scand J Clin Lab Invest , vol.23 , pp. 19-29
    • Kjellman, B.1
  • 15
    • 84874103198 scopus 로고    scopus 로고
    • Multiple breath nitrogen washout: a feasible alternative to mass spectrometry
    • Jensen R, Stanojevic S, Gibney K, Salazar JG, Gustafsson P, et al. (2013) Multiple breath nitrogen washout: a feasible alternative to mass spectrometry. PLoS One 8: e56868.
    • (2013) PLoS One , vol.8
    • Jensen, R.1    Stanojevic, S.2    Gibney, K.3    Salazar, J.G.4    Gustafsson, P.5
  • 16
    • 0015043620 scopus 로고
    • Pulmonary function and response to exercise in cystic fibrosis
    • Godfrey S, Mearns M, (1971) Pulmonary function and response to exercise in cystic fibrosis. Arch Dis Child 46: 144-151.
    • (1971) Arch Dis Child , vol.46 , pp. 144-151
    • Godfrey, S.1    Mearns, M.2
  • 17
    • 0017273804 scopus 로고
    • Dead space ventilation in normal children and children with obstructive airways diease
    • Kerr AA, (1976) Dead space ventilation in normal children and children with obstructive airways diease. Thorax 31: 63-69.
    • (1976) Thorax , vol.31 , pp. 63-69
    • Kerr, A.A.1
  • 18
    • 0038439944 scopus 로고
    • Oak Ridge, Tennessee: Dosimetry Research Group, Health Sciences Research Division, Oak Ridge National Laboratory
    • Williams L (1994) Reference values for total blood volume and cardiac output in humans. Oak Ridge, Tennessee: Dosimetry Research Group, Health Sciences Research Division, Oak Ridge National Laboratory. 51 p.
    • (1994) Reference values for total blood volume and cardiac output in humans , pp. 51
    • Williams, L.1
  • 20
    • 84859568289 scopus 로고    scopus 로고
    • Relationships between the lung clearance index and conductive and acinar ventilation heterogeneity
    • Verbanck S, Paiva M, Schuermans D, Hanon S, Vincken W, et al. (2012) Relationships between the lung clearance index and conductive and acinar ventilation heterogeneity. J Appl Physiol 112: 782-790.
    • (2012) J Appl Physiol , vol.112 , pp. 782-790
    • Verbanck, S.1    Paiva, M.2    Schuermans, D.3    Hanon, S.4    Vincken, W.5
  • 21
    • 84878970875 scopus 로고    scopus 로고
    • Efficacy and Safety of Ivacaftor in Patients Aged 6 to 11 Years with Cystic Fibrosis with a G551D Mutation
    • Davies JC, Wainwright CE, Canny GJ, Chilvers MA, Howenstine MS, et al. (2013) Efficacy and Safety of Ivacaftor in Patients Aged 6 to 11 Years with Cystic Fibrosis with a G551D Mutation. Am J Respir Crit Care Med 187(11): 1219-1225.
    • (2013) Am J Respir Crit Care Med , vol.187 , Issue.11 , pp. 1219-1225
    • Davies, J.C.1    Wainwright, C.E.2    Canny, G.J.3    Chilvers, M.A.4    Howenstine, M.S.5
  • 22
    • 84877593162 scopus 로고    scopus 로고
    • Changes in physiological, functional and structural markers of cystic fibrosis lung disease with treatment of a pulmonary exacerbation
    • Horsley AR, Davies JC, Gray RD, Macleod KA, Donovan J, et al. (2013) Changes in physiological, functional and structural markers of cystic fibrosis lung disease with treatment of a pulmonary exacerbation. Thorax 68: 532-539.
    • (2013) Thorax , vol.68 , pp. 532-539
    • Horsley, A.R.1    Davies, J.C.2    Gray, R.D.3    Macleod, K.A.4    Donovan, J.5
  • 23
    • 84882662774 scopus 로고    scopus 로고
    • Lung Clearance Index as an Outcome Measure for Clinical Trials in Young Children with Cystic Fibrosis: A Pilot Study using Inhaled Hypertonic Saline
    • doi:10.1164/rccm.201302-0219OC
    • Subbarao P, Stanojevic S, Brown M, Jensen R, Rosenfeld M, et al. (2013) Lung Clearance Index as an Outcome Measure for Clinical Trials in Young Children with Cystic Fibrosis: A Pilot Study using Inhaled Hypertonic Saline. Am J Respir Crit Care Med. doi:10.1164/rccm.201302-0219OC.
    • (2013) Am J Respir Crit Care Med
    • Subbarao, P.1    Stanojevic, S.2    Brown, M.3    Jensen, R.4    Rosenfeld, M.5
  • 24
    • 79952504576 scopus 로고    scopus 로고
    • Lung clearance index at 4 years predicts subsequent lung function in children with cystic fibrosis
    • Aurora P, Stanojevic S, Wade A, Oliver C, Kozlowska W, et al. (2011) Lung clearance index at 4 years predicts subsequent lung function in children with cystic fibrosis. Am J Respir Crit Care Med 183: 752-758.
    • (2011) Am J Respir Crit Care Med , vol.183 , pp. 752-758
    • Aurora, P.1    Stanojevic, S.2    Wade, A.3    Oliver, C.4    Kozlowska, W.5
  • 25
    • 39049084491 scopus 로고    scopus 로고
    • Multiple-breath inert gas washout and spirometry versus structural lung disease in cystic fibrosis
    • Gustafsson PM, De Jong PA, Tiddens HA, Lindblad A, (2008) Multiple-breath inert gas washout and spirometry versus structural lung disease in cystic fibrosis. Thorax 63: 129-134.
    • (2008) Thorax , vol.63 , pp. 129-134
    • Gustafsson, P.M.1    De Jong, P.A.2    Tiddens, H.A.3    Lindblad, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.