메뉴 건너뛰기




Volumn 13, Issue 3, 2013, Pages 255-257

Within-laboratory and between-laboratory variability in the measurement of anti-müllerian hormone determined within an external quality assurance scheme

Author keywords

AMH; External quality assurance

Indexed keywords

MUELLERIAN INHIBITING FACTOR;

EID: 84883530882     PISSN: 1642431X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.repbio.2013.04.005     Document Type: Article
Times cited : (29)

References (12)
  • 1
    • 79960293852 scopus 로고    scopus 로고
    • A validated model of serum anti-Müllerian hormone from conception to menopause
    • Kelsey T.W., Wright P., Nelson S.M., Anderson R.A., Wallace W.H.B. A validated model of serum anti-Müllerian hormone from conception to menopause. PLoS ONE 2011, 6(7):e22024.
    • (2011) PLoS ONE , vol.6 , Issue.7
    • Kelsey, T.W.1    Wright, P.2    Nelson, S.M.3    Anderson, R.A.4    Wallace, W.H.B.5
  • 2
    • 70350572458 scopus 로고    scopus 로고
    • Circulating basal anti-Müllerian hormone levels as predictor of ovarian response in women undergoing ovarian stimulation for in vitro fertilization
    • Nardo L.G., Gelbaya T.A., Wilkinson H., Roberts S.A., Yates A., Pemberton P., et al. Circulating basal anti-Müllerian hormone levels as predictor of ovarian response in women undergoing ovarian stimulation for in vitro fertilization. Fertility and Sterility 2009, 92(5):1586-1593.
    • (2009) Fertility and Sterility , vol.92 , Issue.5 , pp. 1586-1593
    • Nardo, L.G.1    Gelbaya, T.A.2    Wilkinson, H.3    Roberts, S.A.4    Yates, A.5    Pemberton, P.6
  • 3
    • 64949163396 scopus 로고    scopus 로고
    • Anti-Müllerian hormone-based approach to controlled ovarian stimulation for assisted conception
    • Nelson S.M., Yates R.W., Lyall H., Jamieson M., Traynor I., Gaudoin M., et al. Anti-Müllerian hormone-based approach to controlled ovarian stimulation for assisted conception. Human Reproduction 2009, 24(4):867-875.
    • (2009) Human Reproduction , vol.24 , Issue.4 , pp. 867-875
    • Nelson, S.M.1    Yates, R.W.2    Lyall, H.3    Jamieson, M.4    Traynor, I.5    Gaudoin, M.6
  • 5
    • 79960462335 scopus 로고    scopus 로고
    • A multicentre evaluation of the new Beckman Coulter anti-Müllerian hormone immunoassay (AMH Gen II)
    • Wallace A.M., Faye S.A., Fleming R., Nelson S.M. A multicentre evaluation of the new Beckman Coulter anti-Müllerian hormone immunoassay (AMH Gen II). Annals of Clinical Biochemistry 2011, 48(4):370-373.
    • (2011) Annals of Clinical Biochemistry , vol.48 , Issue.4 , pp. 370-373
    • Wallace, A.M.1    Faye, S.A.2    Fleming, R.3    Nelson, S.M.4
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J., Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, i307-i310.
    • (1986) Lancet
    • Bland, J.1    Altman, D.2
  • 8
    • 80053563342 scopus 로고    scopus 로고
    • The journey from the old to the new AMH assay: how to avoid getting lost in the values
    • Nelson S.M., La Marca A. The journey from the old to the new AMH assay: how to avoid getting lost in the values. Reproductive Biomedicine Online 2011, 23(4):411-420.
    • (2011) Reproductive Biomedicine Online , vol.23 , Issue.4 , pp. 411-420
    • Nelson, S.M.1    La Marca, A.2
  • 10
    • 33750049314 scopus 로고    scopus 로고
    • Measurement of serum anti-Müllerian hormone by Beckman Coulter ELISA and DSL ELISA: comparison and relevance in assisted reproduction technology (ART)
    • Fréour T., Mirallié S., Bach-Ngohou K., Denis M., Barrière P., Masson D. Measurement of serum anti-Müllerian hormone by Beckman Coulter ELISA and DSL ELISA: comparison and relevance in assisted reproduction technology (ART). Clinica Chimica Acta 2007, 375(1/2):162-164.
    • (2007) Clinica Chimica Acta , vol.375 , Issue.1-2 , pp. 162-164
    • Fréour, T.1    Mirallié, S.2    Bach-Ngohou, K.3    Denis, M.4    Barrière, P.5    Masson, D.6
  • 11
    • 84866367312 scopus 로고    scopus 로고
    • Anti-Müllerian hormone: poor assay reproducibility in a large cohort of subjects suggests sample instability
    • Rustamov O., Smith A., Roberts S.A., Yates A.P., Fitzgerald C., Krishnan M., et al. Anti-Müllerian hormone: poor assay reproducibility in a large cohort of subjects suggests sample instability. Human Reproduction 2012, 27(10):3085-3091.
    • (2012) Human Reproduction , vol.27 , Issue.10 , pp. 3085-3091
    • Rustamov, O.1    Smith, A.2    Roberts, S.A.3    Yates, A.P.4    Fitzgerald, C.5    Krishnan, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.