메뉴 건너뛰기




Volumn 201, Issue , 2013, Pages 468-476

High resolution simultaneous dual liquid level measurement system with CMOS camera and FPGA hardware processor

Author keywords

CMOS image area sensor; Computer vision; FPGA; Image processing; Liquid level measurement; Membrane distillation

Indexed keywords

ALTERNATIVE ENERGY SOURCE; AREA SENSORS; AUTOMATIC MEASUREMENT SYSTEM; AUTOMATIC MEASUREMENTS; HIGH PRECISION SYSTEMS; LIQUID LEVEL MEASUREMENTS; LOW OPERATING TEMPERATURE; MEMBRANE DISTILLATION;

EID: 84883495169     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2013.08.005     Document Type: Article
Times cited : (10)

References (22)
  • 4
    • 0034738081 scopus 로고    scopus 로고
    • Nature of flow on sweeping gas membrane distillation
    • M. Khayet, P. Godino, and J.I. Mengual Nature of flow on sweeping gas membrane distillation J. Membr. Sci. 170 2000 243
    • (2000) J. Membr. Sci. , vol.170 , pp. 243
    • Khayet, M.1    Godino, P.2    Mengual, J.I.3
  • 5
    • 0037443314 scopus 로고    scopus 로고
    • Factors affecting flux and ethanol separation performance in vacuum membrane distillation (VMD)
    • M.A. Izquierdo-Gil, and G. Jonsson Factors affecting flux and ethanol separation performance in vacuum membrane distillation (VMD) J. Membr. Sci. 214 2003 113
    • (2003) J. Membr. Sci. , vol.214 , pp. 113
    • Izquierdo-Gil, M.A.1    Jonsson, G.2
  • 8
    • 84883513012 scopus 로고    scopus 로고
    • Keithley Instruments, Inc. Cleveland, OH, U.S.A. Seventh Printing, Document Number: 2700-900-01 Rev. G
    • Model 2700 Multimeter/Switch System User's Manual August 2003 Keithley Instruments, Inc. Cleveland, OH, U.S.A. Seventh Printing, Document Number: 2700-900-01 Rev. G
    • (2003) Model 2700 Multimeter/Switch System User's Manual
  • 9
    • 68949178681 scopus 로고    scopus 로고
    • Distance measurement based on pixel variation of CCD images
    • October
    • C.-C. Hsu, M.-C. Lu, W.-Y. Wang, and Y.-Y. Lu Distance measurement based on pixel variation of CCD images ISA Trans. 48 October (4) 2009 389 395
    • (2009) ISA Trans. , vol.48 , Issue.4 , pp. 389-395
    • Hsu, C.-C.1    Lu, M.-C.2    Wang, W.-Y.3    Lu, Y.-Y.4
  • 10
    • 72149094076 scopus 로고    scopus 로고
    • Non-contact liquid level measurement with electromagnetic-acoustic resonator sensors
    • (7pp)
    • F. Lucklum, and B. Jakoby Non-contact liquid level measurement with electromagnetic-acoustic resonator sensors Meas. Sci. Technol. 20 12 2009 124002 (7pp)
    • (2009) Meas. Sci. Technol. , vol.20 , Issue.12 , pp. 124002
    • Lucklum, F.1    Jakoby, B.2
  • 11
    • 34250731203 scopus 로고    scopus 로고
    • Continuous liquid level measurement using a linear electrode array
    • DOI 10.1088/0957-0233/18/7/010, PII S0957023307394563, 010
    • R. Casanella, O. Casas, and R. Pallàs-Areny Continuous liquid level measurement using a linear electrode array Meas. Sci. Technol. 18 7 2007 1859 1866 (Pubitemid 46950758)
    • (2007) Measurement Science and Technology , vol.18 , Issue.7 , pp. 1859-1866
    • Casanella, R.1    Casas, O.2    Pallas-Areny, R.3
  • 12
    • 4444383335 scopus 로고    scopus 로고
    • Multi-sensor system using plastic optical fibers for intrinsically safe level measurements
    • October
    • C. Vázquez, A.B. Gonzalo, S. Vargas, and J. Montalvo Multi-sensor system using plastic optical fibers for intrinsically safe level measurements Sens. Actuators A: Phys. 116 October (1) 2004 22 32
    • (2004) Sens. Actuators A: Phys. , vol.116 , Issue.1 , pp. 22-32
    • Vázquez, C.1    Gonzalo, A.B.2    Vargas, S.3    Montalvo, J.4
  • 13
    • 70349466794 scopus 로고    scopus 로고
    • A novel level measurement technique using three capacitive sensors for liquids
    • October
    • H. Canbolat A novel level measurement technique using three capacitive sensors for liquids IEEE Trans. Instrum. Meas. 58 October (10) 2009 3762 3768
    • (2009) IEEE Trans. Instrum. Meas. , vol.58 , Issue.10 , pp. 3762-3768
    • Canbolat, H.1
  • 15
    • 80054748034 scopus 로고    scopus 로고
    • A Spartan3E-based low cost system for gamma-ray detection in small single photon emission computed tomography or positron emission tomography systems
    • (7pp)
    • E. Fysikopuolos, M. Georgiou, N. Efthimiou, S. David, G. Loudos, and G. Matsopoulos A Spartan3E-based low cost system for gamma-ray detection in small single photon emission computed tomography or positron emission tomography systems Meas. Sci. Technol. 22 11 2011 114002 (7pp)
    • (2011) Meas. Sci. Technol. , vol.22 , Issue.11 , pp. 114002
    • Fysikopuolos, E.1    Georgiou, M.2    Efthimiou, N.3    David, S.4    Loudos, G.5    Matsopoulos, G.6
  • 16
    • 80051682920 scopus 로고    scopus 로고
    • Gabor Molnar and Hans-Ulrich Danzebrink Compact field programmable gate array (FPGA)-based multi-axial interferometer for simultaneous tilt and distance measurement in the sub-nanometre range
    • (8pp)
    • S. Strube Gabor Molnar and Hans-Ulrich Danzebrink Compact field programmable gate array (FPGA)-based multi-axial interferometer for simultaneous tilt and distance measurement in the sub-nanometre range Meas. Sci. Technol. 22 9 2011 094026 (8pp)
    • (2011) Meas. Sci. Technol. , vol.22 , Issue.9 , pp. 094026
    • Strube, S.1
  • 17
    • 34248567866 scopus 로고    scopus 로고
    • Low power data processing system with self-reconfigurable architecture
    • DOI 10.1016/j.sysarc.2006.12.008, PII S1383762106001640
    • M.G. Lorenz, L. Mengibar, E. SanMillan, and L. Entrena Low power data processing system with self-reconfigurable architecture J. Syst. Archit. 53 9 2007 568 576 (Pubitemid 46754990)
    • (2007) Journal of Systems Architecture , vol.53 , Issue.9 , pp. 568-576
    • Lorenz, M.G.1    Mengibar, L.2    SanMillan, E.3    Entrena, L.4
  • 18
    • 34249009331 scopus 로고    scopus 로고
    • Single CMOS sensor system for high resolution double volume measurement applied to membrane distillation system
    • M.G. Lorenz, M.A. Izquierdo-Gil, R. Sanchez-Reillo, and C. Fernandez-Pineda Single CMOS sensor system for high resolution double volume measurement applied to membrane distillation system Proc. SPIE 6491 2007 64910P
    • (2007) Proc. SPIE , vol.6491
    • Lorenz, M.G.1    Izquierdo-Gil, M.A.2    Sanchez-Reillo, R.3    Fernandez-Pineda, C.4
  • 19
  • 22
    • 46149099776 scopus 로고    scopus 로고
    • Flow rate influence on direct contact membrane distillation experiments: Different empirical correlations for Nusselt number
    • M.A. Izquierdo-Gil, C. Fernandez-Pineda, and M.G. Lorenz Flow rate influence on direct contact membrane distillation experiments: different empirical correlations for Nusselt number J. Membr. Sci. 321 2008 356 363
    • (2008) J. Membr. Sci. , vol.321 , pp. 356-363
    • Izquierdo-Gil, M.A.1    Fernandez-Pineda, C.2    Lorenz, M.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.