메뉴 건너뛰기




Volumn 185, Issue 8, 2013, Pages 749-757

Impact of a 4th generation iterative reconstruction technique on image quality in low-dose computed tomography of the chest in immunocompromised patients

Author keywords

chest; image quality; iterative reconstruction; low dose computed tomography; radiation exposure

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT REDUCTION; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMMUNOCOMPROMISED PATIENT; LUNG LESION; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NOISE REDUCTION; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; RADIATION ATTENUATION; RADIATION DOSE REDUCTION; RADIOLOGIST; THORAX RADIOGRAPHY;

EID: 84883455268     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-0033-1335577     Document Type: Article
Times cited : (38)

References (30)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • Brenner D. J., Hall E. J. Computed tomography - an increasing source of radiation exposure. N Engl J Med: 2007; 357 2277 2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 3
    • 34247624184 scopus 로고    scopus 로고
    • American College of Radiology white paper on radiation dose in medicine
    • Amis E. S Jr. Butler PF Applegate KE et al. American College of Radiology white paper on radiation dose in medicine. J Am Coll Radiol: 2007; 4 272 284
    • (2007) J Am Coll Radiol , vol.4 , pp. 272-284
    • Amis, E.S.Jr.B.P.A.K.1
  • 4
    • 18044404843 scopus 로고    scopus 로고
    • CT-Expositionspraxis in der Bundesrepublik Deutschland
    • Galanski M., Nagel H. D., Stamm G. CT-Expositionspraxis in der Bundesrepublik Deutschland. Fortschr Röntgenstr: 2001; 173 R1 66
    • (2001) Fortschr Röntgenstr , vol.173
    • Galanski, M.1    Nagel, H.D.2    Stamm, G.3
  • 5
    • 84860549699 scopus 로고    scopus 로고
    • Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT
    • Harrieder A., Geyer L. L., Korner M. et al. Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT. Fortschr Röntgenstr: 2012; 184 443 449
    • (2012) Fortschr Röntgenstr , vol.184 , pp. 443-449
    • Harrieder, A.1    Geyer, L.L.2    Korner, M.3
  • 6
    • 1642493878 scopus 로고    scopus 로고
    • Pulmonary infiltrates in the non-HIV-infected immunocompromised patient: Etiologies, diagnostic strategies, and outcomes
    • Shorr A. F., Susla G. M., O'Grady N. P. Pulmonary infiltrates in the non-HIV-infected immunocompromised patient: etiologies, diagnostic strategies, and outcomes. Chest: 2004; 125 260 271
    • (2004) Chest , vol.125 , pp. 260-271
    • Shorr, A.F.1    Susla, G.M.2    O'Grady, N.P.3
  • 7
    • 7644229250 scopus 로고    scopus 로고
    • Influenza infections after hematopoietic stem cell transplantation: Risk factors, mortality, and the effect of antiviral therapy
    • Nichols W. G., Guthrie K. A., Corey L. et al. Influenza infections after hematopoietic stem cell transplantation: risk factors, mortality, and the effect of antiviral therapy. Clin Infect Dis: 2004; 39 1300 1306
    • (2004) Clin Infect Dis , vol.39 , pp. 1300-1306
    • Nichols, W.G.1    Guthrie, K.A.2    Corey, L.3
  • 8
    • 54849442703 scopus 로고    scopus 로고
    • The challenge of respiratory virus infections in hematopoietic cell transplant recipients
    • Boeckh M. The challenge of respiratory virus infections in hematopoietic cell transplant recipients. Br J Haematol: 2008; 143 455 467
    • (2008) Br J Haematol , vol.143 , pp. 455-467
    • Boeckh, M.1
  • 9
    • 0030854376 scopus 로고    scopus 로고
    • Early detection of pneumonia in febrile neutropenic patients: Use of thin-section CT
    • Heussel C. P., Kauczor H. U., Heussel G. et al. Early detection of pneumonia in febrile neutropenic patients: use of thin-section CT. Am J Roentgenol Am J Roentgenol: 1997; 169 1347 1353
    • (1997) Am J Roentgenol Am J Roentgenol , vol.169 , pp. 1347-1353
    • Heussel, C.P.1    Kauczor, H.U.2    Heussel, G.3
  • 10
    • 14644423238 scopus 로고    scopus 로고
    • Pulmonary infections in the late period after allogeneic bone marrow transplantation: Chest radiography versus computed tomography
    • Schueller G., Matzek W., Kalhs P. et al. Pulmonary infections in the late period after allogeneic bone marrow transplantation: chest radiography versus computed tomography. Eur J Radiol: 2005; 53 489 494
    • (2005) Eur J Radiol , vol.53 , pp. 489-494
    • Schueller, G.1    Matzek, W.2    Kalhs, P.3
  • 11
    • 24344490740 scopus 로고    scopus 로고
    • The role of HRCT versus CXR in children with recurrent pulmonary infections
    • Bayramoglu S., Cimilli T., Aksoy S. et al. The role of HRCT versus CXR in children with recurrent pulmonary infections. Clin Imaging: 2005; 29 317 324
    • (2005) Clin Imaging , vol.29 , pp. 317-324
    • Bayramoglu, S.1    Cimilli, T.2    Aksoy, S.3
  • 12
    • 0030136893 scopus 로고    scopus 로고
    • Hochauflösende Computertomographie der Lunge bei neutropenischen Patienten mit Fieber
    • Heussel C. P., Kauczor H. U., Matzke G. et al. Hochauflösende Computertomographie der Lunge bei neutropenischen Patienten mit Fieber. Fortschr Röntgenstr: 1996; 164 368 375
    • (1996) Fortschr Röntgenstr , vol.164 , pp. 368-375
    • Heussel, C.P.1    Kauczor, H.U.2    Matzke, G.3
  • 13
    • 4143151587 scopus 로고    scopus 로고
    • Reduced radiation dose helical chest CT: Effect on reader evaluation of structures and lung findings
    • Mayo J. R., Kim K. I., MacDonald S. L. et al. Reduced radiation dose helical chest CT: effect on reader evaluation of structures and lung findings. Radiology: 2004; 232 749 756
    • (2004) Radiology , vol.232 , pp. 749-756
    • Mayo, J.R.1    Kim, K.I.2    Macdonald, S.L.3
  • 14
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • Thibault J. B., Sauer K. D., Bouman C. A. et al. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys: 2007; 34 4526 4544
    • (2007) Med Phys , vol.34 , pp. 4526-4544
    • Thibault, J.B.1    Sauer, K.D.2    Bouman, C.A.3
  • 15
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • Hara A. K., Paden R. G., Silva A. C. et al. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. Am J Roentgenol Am J Roentgenol: 2009; 193 764 771
    • (2009) Am J Roentgenol Am J Roentgenol , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3
  • 16
    • 82455217279 scopus 로고    scopus 로고
    • Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT
    • Noel P. B., Fingerle A. A., Renger B. et al. Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT. Am J Roentgenol Am J Roentgenol: 2011; 197 1404 1409
    • (2011) Am J Roentgenol Am J Roentgenol , vol.197 , pp. 1404-1409
    • Noel, P.B.1    Fingerle, A.A.2    Renger, B.3
  • 17
    • 84857231843 scopus 로고    scopus 로고
    • System-Upgrade auf iterative Bildrekonstruktion (IR) in der MDCT des Abdomens: Eine klinische Studie zur detaillierten Parameteroptimierung jenseits der Herstellerempfehlungen am Beispiel der adaptiven statistischen iterativen Rekonstruktionsumgebung (ASIR)
    • Mueck F. G., Korner M., Scherr M. K. et al. System-Upgrade auf iterative Bildrekonstruktion (IR) in der MDCT des Abdomens: Eine klinische Studie zur detaillierten Parameteroptimierung jenseits der Herstellerempfehlungen am Beispiel der adaptiven statistischen iterativen Rekonstruktionsumgebung (ASIR). Fortschr Röntgenstr: 2012; 184 229 238
    • (2012) Fortschr Röntgenstr , vol.184 , pp. 229-238
    • Mueck, F.G.1    Korner, M.2    Scherr, M.K.3
  • 19
    • 84866975896 scopus 로고    scopus 로고
    • Effect of iterative reconstruction techniques on image texture
    • -2011
    • Mehta D., Bayraktar B., Dhanantwari A. Effect of iterative reconstruction techniques on image texture. Insights into Imaging: 2011; 2 01 C-1938 2011
    • (2011) Insights into Imaging , vol.2 , Issue.1
    • Mehta, D.1    Bayraktar, B.2    Dhanantwari, A.3
  • 20
    • 0030025759 scopus 로고    scopus 로고
    • Detection and differential diagnosis of pulmonary infections and tumors in patients with AIDS: Value of chest radiography versus CT
    • Kang E. Y., Staples C. A., McGuinness G. et al. Detection and differential diagnosis of pulmonary infections and tumors in patients with AIDS: value of chest radiography versus CT. Am J Roentgenol Am J Roentgenol: 1996; 166 15 19
    • (1996) Am J Roentgenol Am J Roentgenol , vol.166 , pp. 15-19
    • Kang, E.Y.1    Staples, C.A.2    McGuinness, G.3
  • 21
    • 33749009756 scopus 로고    scopus 로고
    • Thin-section CT findings in hematopoietic stem cell transplantation recipients with respiratory virus pneumonia
    • Franquet T., Rodriguez S., Martino R. et al. Thin-section CT findings in hematopoietic stem cell transplantation recipients with respiratory virus pneumonia. Am J Roentgenol Am J Roentgenol: 2006; 187 1085 1090
    • (2006) Am J Roentgenol Am J Roentgenol , vol.187 , pp. 1085-1090
    • Franquet, T.1    Rodriguez, S.2    Martino, R.3
  • 22
    • 34548213297 scopus 로고    scopus 로고
    • Viral pneumonia after hematopoietic stem cell transplantation: High-resolution CT findings
    • Kanne J. P., Godwin J. D., Franquet T. et al. Viral pneumonia after hematopoietic stem cell transplantation: high-resolution CT findings. J Thorac Imaging: 2007; 22 292 299
    • (2007) J Thorac Imaging , vol.22 , pp. 292-299
    • Kanne, J.P.1    Godwin, J.D.2    Franquet, T.3
  • 23
    • 33846564402 scopus 로고    scopus 로고
    • Noise and resolution in images reconstructed with FBP and OSC algorithms for CT
    • Ziegler A., Kohler T., Proksa R. Noise and resolution in images reconstructed with FBP and OSC algorithms for CT. Med Phys: 2007; 34 585 598
    • (2007) Med Phys , vol.34 , pp. 585-598
    • Ziegler, A.1    Kohler, T.2    Proksa, R.3
  • 24
    • 0034759632 scopus 로고    scopus 로고
    • High-resolution CT: Normal anatomy, techniques, and pitfalls
    • v
    • Griffin C. B., Primack S. L. High-resolution CT: normal anatomy, techniques, and pitfalls. Radiol Clin North Am: 2001; 39 1073 1090, v
    • (2001) Radiol Clin North Am , vol.39 , pp. 1073-1090
    • Griffin, C.B.1    Primack, S.L.2
  • 26
    • 76849115619 scopus 로고    scopus 로고
    • The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT
    • Paul N. S., Blobel J., Prezelj E. et al. The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT. Phys Med Biol: 2010; 55 1363 1380
    • (2010) Phys Med Biol , vol.55 , pp. 1363-1380
    • Paul, N.S.1    Blobel, J.2    Prezelj, E.3
  • 27
    • 76449091107 scopus 로고    scopus 로고
    • Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: Initial experience
    • Prakash P., Kalra M. K., Digumarthy S. R. et al. Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr: 2010; 34 40 45
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 40-45
    • Prakash, P.1    Kalra, M.K.2    Digumarthy, S.R.3
  • 28
    • 79955036642 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: A pilot study
    • Singh S., Kalra M. K., Gilman M. D. et al. Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology: 2011; 259 565 573
    • (2011) Radiology , vol.259 , pp. 565-573
    • Singh, S.1    Kalra, M.K.2    Gilman, M.D.3
  • 29
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): Image quality of low-dose CT examinations in 80 patients
    • Pontana F., Duhamel A., Pagniez J. et al. Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients. Eur Radiol: 2011; 21 636 643
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3
  • 30
    • 80052962265 scopus 로고    scopus 로고
    • Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space
    • Hu X. H., Ding X. F., Wu R. Z. et al. Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space. Clin Radiol: 2011; 66 1023 1029
    • (2011) Clin Radiol , vol.66 , pp. 1023-1029
    • Hu, X.H.1    Ding, X.F.2    Wu, R.Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.