메뉴 건너뛰기




Volumn 28, Issue 5, 2013, Pages 497-504

Cardiac computed tomography and computed tomography angiography in the evaluation of patients prior to transcatheter aortic valve implantation

Author keywords

annulus sizing; para aortic regurgitation; transcatheter aortic valve implantation; transcatheter aortic valve replacement

Indexed keywords

AORTA ROOT; AORTA RUPTURE; AORTA STENOSIS; AORTA VALVE REGURGITATION; CARDIAC IMAGING; DIASTOLE; ECHOCARDIOGRAPHY; FALSE ANEURYSM; HEART CYCLE; HUMAN; MULTICENTER STUDY (TOPIC); MULTIDETECTOR COMPUTED TOMOGRAPHY; PARA AORTIC VALVE REGURGITATION; PRACTICE GUIDELINE; PRIORITY JOURNAL; REVIEW; SYSTOLE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 84883452749     PISSN: 02684705     EISSN: 15317080     Source Type: Journal    
DOI: 10.1097/HCO.0b013e32836245c1     Document Type: Review
Times cited : (19)

References (18)
  • 1
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010; 363:1597-1607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 2
    • 0034162080 scopus 로고    scopus 로고
    • Observed and relative survival after aortic valve replacement
    • Kvidal P, Bergstrom R, Horte LG, et al. Observed and relative survival after aortic valve replacement. J Am Coll Cardiol 2000; 35:747-756.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 747-756
    • Kvidal, P.1    Bergstrom, R.2    Horte, L.G.3
  • 3
    • 84872144910 scopus 로고    scopus 로고
    • Impact of residual regurgitation after aortic valve replacement
    • Sponga S, Perron J, Dagenais F, et al. Impact of residual regurgitation after aortic valve replacement. Eur J Cardiothorac Surg 2012; 42:486-492.
    • (2012) Eur J Cardiothorac Surg , vol.42 , pp. 486-492
    • Sponga, S.1    Perron, J.2    Dagenais, F.3
  • 4
    • 84871290564 scopus 로고    scopus 로고
    • Impact of postprocedural aortic regurgitation on mortality after transcatheter aortic valve implantation
    • Hayashida K, Lefevre T, Chevalier B, et al. Impact of postprocedural aortic regurgitation on mortality after transcatheter aortic valve implantation. JACC Cardiovasc Interv 2012; 12:1247-1256.
    • (2012) JACC Cardiovasc Interv , vol.12 , pp. 1247-1256
    • Hayashida, K.1    Lefevre, T.2    Chevalier, B.3
  • 5
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic valve replacement
    • Kodali SK, Williams MR, Smith CR, et al. Two-year outcomes after transcatheter or surgical aortic valve replacement. N Engl J Med 2012; 366:1686-1695.
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 6
    • 84870736119 scopus 로고    scopus 로고
    • Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloonexpandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial
    • Wilson AB, Webb JG, Freeman M, et al. Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloonexpandable valves: comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. J Cardiovasc Comput Tomogr 2012; 6:406-414.
    • (2012) J Cardiovasc Comput Tomogr , vol.6 , pp. 406-414
    • Wilson, A.B.1    Webb, J.G.2    Freeman, M.3
  • 7
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: Implications for sizing of transcatheter heart valves
    • Willson AB, Webb JG, LaBounty TM, et al. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: implications for sizing of transcatheter heart valves. J Am Coll Cardiol 2012; 59:1287-1294.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3
  • 8
    • 84868618362 scopus 로고    scopus 로고
    • Prosthesis oversizing in balloonexpandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root
    • Blanke P, Reinohl J, Schlensak C, et al. Prosthesis oversizing in balloonexpandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv 2012; 5:540-638.
    • (2012) Circ Cardiovasc Interv , vol.5 , pp. 540-638
    • Blanke, P.1    Reinohl, J.2    Schlensak, C.3
  • 9
    • 84859164235 scopus 로고    scopus 로고
    • Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
    • Jilaihawi H, Kashif M, Fontana G, et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 2012; 59:1275-1286.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1275-1286
    • Jilaihawi, H.1    Kashif, M.2    Fontana, G.3
  • 10
    • 84871292882 scopus 로고    scopus 로고
    • Impact of CT-guided valve sizing on postprocedural aortic regurgitation in transcatheter aortic valve implantation
    • Hayashida K, Bouvier E, Lefevre T, et al. Impact of CT-guided valve sizing on postprocedural aortic regurgitation in transcatheter aortic valve implantation. EuroIntervention 2012; 8:546-555.
    • (2012) EuroIntervention , vol.8 , pp. 546-555
    • Hayashida, K.1    Bouvier, E.2    Lefevre, T.3
  • 11
    • 84855403987 scopus 로고    scopus 로고
    • Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: Insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy
    • Hamdan A, Guetta V, Konen E, et al. Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 2012; 59:119-127.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 119-127
    • Hamdan, A.1    Guetta, V.2    Konen, E.3
  • 12
    • 77950501005 scopus 로고    scopus 로고
    • Three dimensional evaluation of the aortic annulus using multislice computer tomography: Are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?
    • Schultz CJ, Moelker A, Piazza N, et al. Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 2010; 31:849-856.
    • (2010) Eur Heart J , vol.31 , pp. 849-856
    • Schultz, C.J.1    Moelker, A.2    Piazza, N.3
  • 13
    • 68949174075 scopus 로고    scopus 로고
    • Geometry and degree of apposition of the CoreValve Revalving System (CRS) with multislice computer tomography after implantation in patients with aortic stenosis
    • Schultz CJ, Weustink A, Piazza N, et al. Geometry and degree of apposition of the CoreValve Revalving System (CRS) with multislice computer tomography after implantation in patients with aortic stenosis. J Am Coll Cardiol 2009; 54:911-918.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 911-918
    • Schultz, C.J.1    Weustink, A.2    Piazza, N.3
  • 14
    • 84866379958 scopus 로고    scopus 로고
    • Conformational pulsatile changes of the aortic annulus: Impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement
    • Blanke P, Russe M, Leipsic JA, et al. Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement. JACC Cardiovasc Interv 2012; 9:984-994.
    • (2012) JACC Cardiovasc Interv , vol.9 , pp. 984-994
    • Blanke, P.1    Russe, M.2    Leipsic, J.A.3
  • 15
    • 84857055684 scopus 로고    scopus 로고
    • Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode
    • Wuest W, Anders K, Schuhbaeck A, et al. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol 2012; 22:51-58.
    • (2012) Eur Radiol , vol.22 , pp. 51-58
    • Wuest, W.1    Anders, K.2    Schuhbaeck, A.3
  • 16
    • 0037686710 scopus 로고    scopus 로고
    • Noninvasive intravenous coronary angiography using electron beam tomography and multislice computed tomography
    • Leber AW, Knez A, Becker C, et al. Noninvasive intravenous coronary angiography using electron beam tomography and multislice computed tomography. Heart 2003; 89:633-639.
    • (2003) Heart , vol.89 , pp. 633-639
    • Leber, A.W.1    Knez, A.2    Becker, C.3
  • 17
    • 36949034540 scopus 로고    scopus 로고
    • Contrast-enhanced 64-slice computed tomography in detection and evaluation of anomalous coronary arteries
    • Karaca M, Kirilmaz A, Oncel G, et al. Contrast-enhanced 64-slice computed tomography in detection and evaluation of anomalous coronary arteries. Tohoku J Exp Med 2007; 213:249-259.
    • (2007) Tohoku J Exp Med , vol.213 , pp. 249-259
    • Karaca, M.1    Kirilmaz, A.2    Oncel, G.3
  • 18
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002; 106:3006-3008.
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.