-
1
-
-
11144238881
-
Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain
-
15625463 10.1097/01.TA.0000133573.53587.2E
-
Schep NW, Haverlag R, van Vugt AB (2004) Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma 57(6):1299-1302
-
(2004)
J Trauma
, vol.57
, Issue.6
, pp. 1299-1302
-
-
Schep, N.W.1
Haverlag, R.2
Van Vugt, A.B.3
-
2
-
-
0029314802
-
Early results of percutaneous iliosacral screws placed with the patient in the supine position
-
7623172 10.1097/00005131-199506000-00005
-
Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207-214
-
(1995)
J Orthop Trauma
, vol.9
, Issue.3
, pp. 207-214
-
-
Routt, Jr.M.L.1
Kregor, P.J.2
Simonian, P.T.3
Mayo, K.A.4
-
3
-
-
30944447863
-
An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws
-
16418646 10.1097/01.brs.0000194788.45002.1b
-
Smith HE, Yuan PS, Sasso R, Papadopolous S, Vaccaro AR (2006) An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine 31(2):234-238
-
(2006)
Spine
, vol.31
, Issue.2
, pp. 234-238
-
-
Smith, H.E.1
Yuan, P.S.2
Sasso, R.3
Papadopolous, S.4
Vaccaro, A.R.5
-
4
-
-
14844336330
-
Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy
-
15677930 10.1097/00005131-200502000-00010 1:STN:280: DC%2BD2M%2FltVaitw%3D%3D Epub 2005/01/29
-
Sagi HC, Lindvall EM (2005) Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy. J Orthop Trauma 19(2):130-133 Epub 2005/01/29
-
(2005)
J Orthop Trauma
, vol.19
, Issue.2
, pp. 130-133
-
-
Sagi, H.C.1
Lindvall, E.M.2
-
5
-
-
0029689344
-
Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study
-
8667109 10.1097/00005131-199604000-00005 Epub 1996/01/01
-
Routt ML Jr, Simonian PT, Agnew SG, Mann FA (1996) Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. J Orthop Trauma 10(3):171-177 Epub 1996/01/01
-
(1996)
J Orthop Trauma
, vol.10
, Issue.3
, pp. 171-177
-
-
Routt, Jr.M.L.1
Simonian, P.T.2
Agnew, S.G.3
Mann, F.A.4
-
6
-
-
0024522004
-
Internal fixation of pelvic ring fractures
-
2706863
-
Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop Relat Res 242:83-97
-
(1989)
Clin Orthop Relat Res
, vol.242
, pp. 83-97
-
-
Matta, J.M.1
Saucedo, T.2
-
7
-
-
0025771195
-
CT-guided fixation of sacral fractures and sacroiliac joint disruptions
-
2068323 1:STN:280:DyaK3M3pslWjsg%3D%3D
-
Nelson DW, Duwelius PJ (1991) CT-guided fixation of sacral fractures and sacroiliac joint disruptions. Radiology 180(2):527-532
-
(1991)
Radiology
, vol.180
, Issue.2
, pp. 527-532
-
-
Nelson, D.W.1
Duwelius, P.J.2
-
8
-
-
0031266643
-
Iliosacral screw fixation: Early complications of the percutaneous technique
-
9415865 10.1097/00005131-199711000-00007 Epub 1998/01/07
-
Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11(8):584-589 Epub 1998/01/07
-
(1997)
J Orthop Trauma
, vol.11
, Issue.8
, pp. 584-589
-
-
Routt, Jr.M.L.1
Simonian, P.T.2
Mills, W.J.3
-
9
-
-
0035708541
-
Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy
-
11835615 10.3109/10929080109146084 1:STN:280:DC%2BD387gtlKqug%3D%3D
-
Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S et al (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 6(4):204-211
-
(2001)
Comput Aided Surg
, vol.6
, Issue.4
, pp. 204-211
-
-
Tonetti, J.1
Carrat, L.2
Blendea, S.3
Merloz, P.4
Troccaz, J.5
Lavallee, S.6
-
10
-
-
67649791453
-
Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure
-
19034594 10.1007/s11999-008-0632-6 Epub 2008/11/27
-
Zwingmann J, Konrad G, Kotter E, Sudkamp NP, Oberst M (2009) Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res 467(7):1833-1838 Epub 2008/11/27
-
(2009)
Clin Orthop Relat Res
, vol.467
, Issue.7
, pp. 1833-1838
-
-
Zwingmann, J.1
Konrad, G.2
Kotter, E.3
Sudkamp, N.P.4
Oberst, M.5
-
11
-
-
78650847385
-
Percutaneous iliosacral screw insertion: Malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional)
-
20526214 10.1097/TA.0b013e3181d862db 1:STN:280:DC%2BC3M%2FislyksQ%3D%3D Epub 2010/06/08
-
Zwingmann J, Konrad G, Mehlhorn AT, Sudkamp NP, Oberst M (2010) Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional). J Trauma 69(6):1501-1506 Epub 2010/06/08
-
(2010)
J Trauma
, vol.69
, Issue.6
, pp. 1501-1506
-
-
Zwingmann, J.1
Konrad, G.2
Mehlhorn, A.T.3
Sudkamp, N.P.4
Oberst, M.5
-
12
-
-
0035191045
-
Accuracy of computer-guided screw fixation of the sacroiliac joint
-
11764364 10.1097/00003086-200112000-00036
-
Gautier E, Bachler R, Heini PF, Nolte LP (2001) Accuracy of computer-guided screw fixation of the sacroiliac joint. Clin Orthop Relat Res 393:310-317
-
(2001)
Clin Orthop Relat Res
, vol.393
, pp. 310-317
-
-
Gautier, E.1
Bachler, R.2
Heini, P.F.3
Nolte, L.P.4
-
13
-
-
0035103298
-
Navigation assisted by image conversion. An experimental study on pelvic screw fixation
-
11284352 10.1007/s001130050717 1:STN:280:DC%2BD3M3kslGgug%3D%3D
-
Stockle U, Konig B, Hofstetter R, Nolte LP, Haas NP (2001) Navigation assisted by image conversion. An experimental study on pelvic screw fixation. Unfallchirurg 104(3):215-220
-
(2001)
Unfallchirurg
, vol.104
, Issue.3
, pp. 215-220
-
-
Stockle, U.1
Konig, B.2
Hofstetter, R.3
Nolte, L.P.4
Haas, N.P.5
-
14
-
-
0028092022
-
Percutaneous computed tomography-guided stabilization of posterior pelvic fractures
-
7924036
-
Ebraheim NA, Coombs R, Jackson WT, Rusin JJ (1994) Percutaneous computed tomography-guided stabilization of posterior pelvic fractures. Clin Orthop Relat Res 307:222-228
-
(1994)
Clin Orthop Relat Res
, vol.307
, pp. 222-228
-
-
Ebraheim, N.A.1
Coombs, R.2
Jackson, W.T.3
Rusin, J.J.4
-
15
-
-
0032033101
-
Imaging assessment of sacroiliac screw placement relative to the neuroforamen
-
9530790 10.1097/00007632-199803010-00011 1:STN:280:DyaK1c7ptF2hsQ%3D%3D
-
Goldberg BA, Lindsey RW, Foglar C, Hedrick TD, Miclau T, Hadad JL (1998) Imaging assessment of sacroiliac screw placement relative to the neuroforamen. Spine 23(5):585-589
-
(1998)
Spine
, vol.23
, Issue.5
, pp. 585-589
-
-
Goldberg, B.A.1
Lindsey, R.W.2
Foglar, C.3
Hedrick, T.D.4
Miclau, T.5
Hadad, J.L.6
-
16
-
-
0032455890
-
Iliosacral screw insertion using computer-assisted CT image guidance: A laboratory study
-
10379978 10.3109/10929089809148149 1:STN:280:DyaK1Mzgs1KntA%3D%3D
-
Barrick EF, O'Mara JW, Lane HE 3rd (1998) Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study. Comput Aided Surg 3(6):289-296
-
(1998)
Comput Aided Surg
, vol.3
, Issue.6
, pp. 289-296
-
-
Barrick, E.F.1
O'Mara, J.W.2
Lane III, H.E.3
-
17
-
-
0031716042
-
Percutaneous iliosacral screw placement using image guided techniques
-
9755769 10.1097/00003086-199809000-00013
-
Tonetti J, Carrat L, Lavallee S, Pittet L, Merloz P, Chirossel JP (1998) Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop Relat Res 354:103-110
-
(1998)
Clin Orthop Relat Res
, vol.354
, pp. 103-110
-
-
Tonetti, J.1
Carrat, L.2
Lavallee, S.3
Pittet, L.4
Merloz, P.5
Chirossel, J.P.6
-
18
-
-
9444220758
-
Outcome after fixation of unstable posterior pelvic ring injuries
-
8769448 10.1097/00003086-199608000-00020
-
Cole JD, Blum DA, Ansel LJ (1996) Outcome after fixation of unstable posterior pelvic ring injuries. Clin Orthop Relat Res 329:160-179
-
(1996)
Clin Orthop Relat Res
, vol.329
, pp. 160-179
-
-
Cole, J.D.1
Blum, D.A.2
Ansel, L.J.3
-
19
-
-
0036172601
-
Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws
-
11937873 10.1097/00003086-200202000-00014
-
Hinsche AF, Giannoudis PV, Smith RM (2002) Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res 395:135-144
-
(2002)
Clin Orthop Relat Res
, vol.395
, pp. 135-144
-
-
Hinsche, A.F.1
Giannoudis, P.V.2
Smith, R.M.3
-
20
-
-
0033072966
-
Early fixation of the vertically unstable pelvis: The role of iliosacral screw fixation of the posterior lesion
-
10052785 10.1097/00005131-199902000-00007 1:STN:280:DyaK1M7mtVWmsg%3D%3D
-
Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, O'Brien PJ (1999) Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma 13(2):107-113
-
(1999)
J Orthop Trauma
, vol.13
, Issue.2
, pp. 107-113
-
-
Keating, J.F.1
Werier, J.2
Blachut, P.3
Broekhuyse, H.4
Meek, R.N.5
O'Brien, P.J.6
-
21
-
-
9444270931
-
Closed reduction and percutaneous skeletal fixation of sacral fractures
-
8769443 10.1097/00003086-199608000-00015
-
Routt ML Jr, Simonian PT (1996) Closed reduction and percutaneous skeletal fixation of sacral fractures. Clin Orthop Relat Res 329:121-128
-
(1996)
Clin Orthop Relat Res
, vol.329
, pp. 121-128
-
-
Routt, Jr.M.L.1
Simonian, P.T.2
-
22
-
-
0343729918
-
The lumbosacral nerves in relation to dorsal S1 screw placement and their locations on plain radiographs
-
10741369 1:STN:280:DC%2BD3c3gtlCisg%3D%3D
-
Ebraheim NA, Haman SP, Xu R, Stanescu S, Yeasting RA (2000) The lumbosacral nerves in relation to dorsal S1 screw placement and their locations on plain radiographs. Orthopedics 23(3):245-247
-
(2000)
Orthopedics
, vol.23
, Issue.3
, pp. 245-247
-
-
Ebraheim, N.A.1
Haman, S.P.2
Xu, R.3
Stanescu, S.4
Yeasting, R.A.5
-
23
-
-
0033088684
-
Superior gluteal artery injury during iliosacral screw placement
-
10206255 10.1097/00005131-199903000-00011 1:STN:280:DyaK1M3itFSqtA%3D%3D
-
Altman DT, Jones CB, Routt ML Jr (1999) Superior gluteal artery injury during iliosacral screw placement. J Orthop Trauma 13(3):220-227
-
(1999)
J Orthop Trauma
, vol.13
, Issue.3
, pp. 220-227
-
-
Altman, D.T.1
Jones, C.B.2
Routt, Jr.M.L.3
-
24
-
-
0030832256
-
Pseudoaneurysm of the superior gluteal arterial system: An unusual cause of pain after a pelvic fracture
-
9253929 10.1097/00005373-199707000-00037 1:STN:280:DyaK2szpsF2nsA%3D%3D
-
Stephen DJ (1997) Pseudoaneurysm of the superior gluteal arterial system: an unusual cause of pain after a pelvic fracture. J Trauma 43(1):146-149
-
(1997)
J Trauma
, vol.43
, Issue.1
, pp. 146-149
-
-
Stephen, D.J.1
-
25
-
-
0029789346
-
Proximity of iliosacral screws to neurovascular structures after internal fixation
-
8769451 10.1097/00003086-199608000-00023
-
Templeman D, Schmidt A, Freese J, Weisman I (1996) Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res 329:194-198
-
(1996)
Clin Orthop Relat Res
, vol.329
, pp. 194-198
-
-
Templeman, D.1
Schmidt, A.2
Freese, J.3
Weisman, I.4
-
26
-
-
0036633039
-
Fluoroscopic positioning of sacroiliac screws in 88 patients
-
12131388 10.1097/00005373-200207000-00009
-
van den Bosch EW, van Zwienen CM, van Vugt AB (2002) Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma 53(1):44-48
-
(2002)
J Trauma
, vol.53
, Issue.1
, pp. 44-48
-
-
Van Den Bosch, E.W.1
Van Zwienen, C.M.2
Van Vugt, A.B.3
-
27
-
-
60549097911
-
Levels of evidence in research published in the journal of bone and joint surgery (American volume) over the last thirty years
-
19181987 10.2106/JBJS.H.00108 Epub 2009/02/03
-
Hanzlik S, Mahabir RC, Baynosa RC, Khiabani KT (2009) Levels of evidence in research published in The journal of bone and joint surgery (American volume) over the last thirty years. J Bone Joint Surg Am 91(2):425-428 Epub 2009/02/03
-
(2009)
J Bone Joint Surg Am
, vol.91
, Issue.2
, pp. 425-428
-
-
Hanzlik, S.1
Mahabir, R.C.2
Baynosa, R.C.3
Khiabani, K.T.4
-
28
-
-
0024510011
-
Grading the outcome of pelvic fractures
-
1:STN:280:DyaL1M7nsV2isw%3D%3D Epub 1989/03/01
-
Majeed SA (1989) Grading the outcome of pelvic fractures. J Bone Joint Surg British Vol 71(2):304-306 Epub 1989/03/01
-
(1989)
J Bone Joint Surg British Vol
, vol.71
, Issue.2
, pp. 304-306
-
-
Majeed, S.A.1
-
29
-
-
0036174973
-
Staged reconstruction of pelvic ring disruption: Differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions
-
11818803 10.1097/00005131-200202000-00004 1:STN:280: DC%2BD38%2FptVGisQ%3D%3D Epub 2002/01/31
-
Rommens PM, Hessmann MH (2002) Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions. J Orthop Trauma 16(2):92-98 Epub 2002/01/31
-
(2002)
J Orthop Trauma
, vol.16
, Issue.2
, pp. 92-98
-
-
Rommens, P.M.1
Hessmann, M.H.2
-
30
-
-
31744432223
-
Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery
-
16244852 10.1007/s00113-005-1002-4 1:STN:280:DC%2BD28%2FmsFOjtQ%3D%3D
-
Stockle U, Konig B, Schaffler A, Zschernack T, Haas NP (2006) Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery. Unfallchirurg 109(1):30-40
-
(2006)
Unfallchirurg
, vol.109
, Issue.1
, pp. 30-40
-
-
Stockle, U.1
Konig, B.2
Schaffler, A.3
Zschernack, T.4
Haas, N.P.5
-
31
-
-
2542497793
-
Computer-guidance in percutaneous screw stabilization of the iliosacral joint
-
15187858 10.1097/01.blo.0000128644.46013.08
-
Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res 422:201-207
-
(2004)
Clin Orthop Relat Res
, vol.422
, pp. 201-207
-
-
Arand, M.1
Kinzl, L.2
Gebhard, F.3
-
32
-
-
17644405424
-
Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: A cadaver model
-
15795574 10.1097/01.bot.0000151821.79827.fb
-
Collinge C, Coons D, Tornetta P, Aschenbrenner J (2005) Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model. J Orthop Trauma 19(4):254-258
-
(2005)
J Orthop Trauma
, vol.19
, Issue.4
, pp. 254-258
-
-
Collinge, C.1
Coons, D.2
Tornetta, P.3
Aschenbrenner, J.4
-
33
-
-
35348860424
-
The accuracy of computer-assisted percutaneous iliosacral screw placement
-
17960680
-
Day AC, Stott PM, Boden RA (2007) The accuracy of computer-assisted percutaneous iliosacral screw placement. Clin Orthop Relat Res 463:179-186
-
(2007)
Clin Orthop Relat Res
, vol.463
, pp. 179-186
-
-
Day, A.C.1
Stott, P.M.2
Boden, R.A.3
-
34
-
-
77149145191
-
Variability of the screw position after 3D-navigated sacroiliac screw fixation. Influence of the surgeon's experience with the navigation technique
-
(Epub 2009/10/29). Variabilitat der Schraubenlage bei 3D-navigierter Sakrumverschraubung. Einfluss der operateurspezifischen Navigationserfahrung
-
Konrad G, Zwingmann J, Kotter E, Sudkamp N, Oberst M (2010) [Variability of the screw position after 3D-navigated sacroiliac screw fixation. Influence of the surgeon's experience with the navigation technique]. Unfallchirurg 113(1): 29-35. (Epub 2009/10/29). Variabilitat der Schraubenlage bei 3D-navigierter Sakrumverschraubung. Einfluss der operateurspezifischen Navigationserfahrung
-
(2010)
Unfallchirurg
, vol.113
, Issue.1
, pp. 29-35
-
-
Konrad, G.1
Zwingmann, J.2
Kotter, E.3
Sudkamp, N.4
Oberst, M.5
|