메뉴 건너뛰기




Volumn 14, Issue 5, 2013, Pages 172-174

Impact of a multi-hospital intervention utilising screening, hand hygiene education and pulsed xenon ultraviolet (PX-UV) on the rate of hospital associated meticillin resistant Staphylococcus aureus infection

Author keywords

bacterial contamination; disinfection; environment; healthcare associated infections; infection prevention and control; MRSA; patient safety

Indexed keywords


EID: 84883365880     PISSN: 17571774     EISSN: 17571782     Source Type: Journal    
DOI: 10.1177/1757177413490813     Document Type: Article
Times cited : (26)

References (15)
  • 1
    • 44449130943 scopus 로고    scopus 로고
    • An integrative review of the current evidence on the relationship between hand hygiene interventions and the incidence of health care-associated infections
    • Backman C,Zoutman D,Marck P.An integrative review of the current evidence on the relationship between hand hygiene interventions and the incidence of health care-associated infections.American Journal of Infection Control. 2007;36 (5): 333-48.
    • (2007) American Journal of Infection Control , vol.36 , Issue.5 , pp. 333-348
    • Backman, C.1    Zoutman, D.2    Marck, P.3
  • 2
    • 0031229649 scopus 로고    scopus 로고
    • Environmental contamination due to methicillin-resistant Staphylococcus aureus: possible infection control implications
    • Boyce J,Potter-Bynoe G,Chenevert C,King T.Environmental contamination due to methicillin-resistant Staphylococcus aureus: possible infection control implications.Infection Control and Hospital Epidemiology. 1997;18 (9): 622-7.
    • (1997) Infection Control and Hospital Epidemiology , vol.18 , Issue.9 , pp. 622-627
    • Boyce, J.1    Potter-Bynoe, G.2    Chenevert, C.3    King, T.4
  • 5
    • 23044472083 scopus 로고    scopus 로고
    • Reduction in nosocomial transmission of drug-resistant bacteria after an introduction of an alcohol based hand rub
    • Gordon F,Schultz M,Huber R,Gill J.Reduction in nosocomial transmission of drug-resistant bacteria after an introduction of an alcohol based hand rub.Infection Control and Hospital Epidemiology. 2005;26 (7): 650-3.
    • (2005) Infection Control and Hospital Epidemiology , vol.26 , Issue.7 , pp. 650-653
    • Gordon, F.1    Schultz, M.2    Huber, R.3    Gill, J.4
  • 6
    • 84861052166 scopus 로고    scopus 로고
    • Successful veterans affairs initiative to prevent methicillin-resistant Staphylococcus aureus infections revisited
    • Gurieva T,Bootsma M,Bonten M.Successful veterans affairs initiative to prevent methicillin-resistant Staphylococcus aureus infections revisited.Clinincal Infectious Diseases. 2012;54 (11): 1618-20.
    • (2012) Clinincal Infectious Diseases , vol.54 , Issue.11 , pp. 1618-1620
    • Gurieva, T.1    Bootsma, M.2    Bonten, M.3
  • 7
    • 33749574575 scopus 로고    scopus 로고
    • Risk of acquiring antibiotic-resistant bacteria from prior room occupants
    • Huang S,Datta R,Platt R.Risk of acquiring antibiotic-resistant bacteria from prior room occupants.Archives of Internal Medicine. 2006;166 (18): 1945-51.
    • (2006) Archives of Internal Medicine , vol.166 , Issue.18 , pp. 1945-1951
    • Huang, S.1    Datta, R.2    Platt, R.3
  • 9
    • 84883329087 scopus 로고    scopus 로고
    • The use of portable pulsed xenon ultraviolet light (PPX-UV) after terminal cleaning was associated with a dramatic decrease in the hospital-associated Clostridium difficile infection (HA-CDI) rate in a community hospital
    • 2011 Poster presented at Infectious Diseases Society of America National Conference
    • Levin J,Riley L,Parrish C,English D.The use of portable pulsed xenon ultraviolet light (PPX-UV) after terminal cleaning was associated with a dramatic decrease in the hospital-associated Clostridium difficile infection (HA-CDI) rate in a community hospital. Poster presented at Infectious Diseases Society of America National Conference; 2011; 2011.
    • (2011)
    • Levin, J.1    Riley, L.2    Parrish, C.3    English, D.4
  • 13
    • 84883337608 scopus 로고    scopus 로고
    • Use of pulse xenon ultraviolet to deactivate Clostridium difficile, methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococci
    • 2010 SHEA Fifth Decennial Conference; Atlanta, GA;
    • Stibich M.Use of pulse xenon ultraviolet to deactivate Clostridium difficile, methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococci. SHEA Fifth Decennial Conference; 2010Atlanta, GA; 2010.
    • (2010)
    • Stibich, M.1
  • 15
    • 33645571021 scopus 로고    scopus 로고
    • Effect of targeted surveillance for control of methicillin-resistant Staphylococcus aureus in a community hospital system
    • West T,Guerry C,Hiott M,Morrow N,Ward K,Salgado C.Effect of targeted surveillance for control of methicillin-resistant Staphylococcus aureus in a community hospital system.Infection Control and Hospital Epidemiology. 2006;27 (3): 233-8.
    • (2006) Infection Control and Hospital Epidemiology , vol.27 , Issue.3 , pp. 233-238
    • West, T.1    Guerry, C.2    Hiott, M.3    Morrow, N.4    Ward, K.5    Salgado, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.