메뉴 건너뛰기




Volumn 42, Issue 5, 2013, Pages 361-364.e1

Physical activity monitoring: Addressing the difficulties of accurately detecting slow walking speeds

Author keywords

Chronic obstructive pulmonary disease; Incremental shuttle walk test; Physical activity; Reliability and validity; Sensitivity

Indexed keywords

ADULT; ARTICLE; CHRONIC OBSTRUCTIVE LUNG DISEASE; ENERGY EXPENDITURE; FEMALE; GENERAL DEVICE; HUMAN; MAJOR CLINICAL STUDY; MALE; METABOLIC EQUIVALENT; MULTISENSOR ACTIVITY MONITOR; PEDOMETER; PHYSICAL ACTIVITY; PRIORITY JOURNAL; WALKING SPEED;

EID: 84883255415     PISSN: 01479563     EISSN: 15273288     Source Type: Journal    
DOI: 10.1016/j.hrtlng.2013.06.004     Document Type: Article
Times cited : (11)

References (23)
  • 1
    • 33847677739 scopus 로고    scopus 로고
    • Regular physical activity modifies smoking-related lung function decline and reduces risk of chronic obstructive pulmonary disease: a population-based cohort study
    • Garcia-Aymerich J., Lange P., Benet M., Schnohr P., Anto J.M. Regular physical activity modifies smoking-related lung function decline and reduces risk of chronic obstructive pulmonary disease: a population-based cohort study. Am J Respir Crit Care Med 2007, 175(5):458-463.
    • (2007) Am J Respir Crit Care Med , vol.175 , Issue.5 , pp. 458-463
    • Garcia-Aymerich, J.1    Lange, P.2    Benet, M.3    Schnohr, P.4    Anto, J.M.5
  • 2
    • 80051523309 scopus 로고    scopus 로고
    • Physical activity is the strongest predictor of all-cause mortality in patients with COPD: a prospective cohort study
    • Waschki B., Kirsten A., Holz O., et al. Physical activity is the strongest predictor of all-cause mortality in patients with COPD: a prospective cohort study. Chest 2011, 140(2):331-342.
    • (2011) Chest , vol.140 , Issue.2 , pp. 331-342
    • Waschki, B.1    Kirsten, A.2    Holz, O.3
  • 3
    • 33748480212 scopus 로고    scopus 로고
    • Regular physical activity reduces hospital admission and mortality in chronic obstructive pulmonary disease: a population based cohort study
    • Garcia-Aymerich J., Lange P., Benet M., Schnohr P., Anto J.M. Regular physical activity reduces hospital admission and mortality in chronic obstructive pulmonary disease: a population based cohort study. Thorax 2006, 61(9):772-778.
    • (2006) Thorax , vol.61 , Issue.9 , pp. 772-778
    • Garcia-Aymerich, J.1    Lange, P.2    Benet, M.3    Schnohr, P.4    Anto, J.M.5
  • 4
    • 84856714232 scopus 로고    scopus 로고
    • Does exercise training change physical activity in people with COPD? A systematic review and meta-analysis
    • Cindy Ng L.W., Mackney J., Jenkins S., Hill K. Does exercise training change physical activity in people with COPD? A systematic review and meta-analysis. Chron Respir Dis 2012, 9(1):17-26.
    • (2012) Chron Respir Dis , vol.9 , Issue.1 , pp. 17-26
    • Cindy Ng, L.W.1    Mackney, J.2    Jenkins, S.3    Hill, K.4
  • 5
    • 2642676050 scopus 로고    scopus 로고
    • Evaluation of a movement detector to measure daily activity in patients with chronic lung disease
    • Schonhofer B., Ardes P., Geibel M., Kohler D., Jones P.W. Evaluation of a movement detector to measure daily activity in patients with chronic lung disease. Eur Respir J 1997, 10(12):2814-2819.
    • (1997) Eur Respir J , vol.10 , Issue.12 , pp. 2814-2819
    • Schonhofer, B.1    Ardes, P.2    Geibel, M.3    Kohler, D.4    Jones, P.W.5
  • 6
    • 0036900139 scopus 로고    scopus 로고
    • Comparison of pedometer and accelerometer measures of free-living physical activity
    • Tudor-Locke C., Ainsworth B.E., Thompson R.W., Matthews C.E. Comparison of pedometer and accelerometer measures of free-living physical activity. Med Sci Sports Exerc 2002, 34(12):2045-2051.
    • (2002) Med Sci Sports Exerc , vol.34 , Issue.12 , pp. 2045-2051
    • Tudor-Locke, C.1    Ainsworth, B.E.2    Thompson, R.W.3    Matthews, C.E.4
  • 7
    • 84865962904 scopus 로고    scopus 로고
    • Reliability of pedometers to measure step counts in patients with chronic respiratory disease
    • Turner L.J., Houchen L., Williams J., Singh S.J. Reliability of pedometers to measure step counts in patients with chronic respiratory disease. JCardiopulmonary Rehabil Prev 2012, 32(5):284-291.
    • (2012) JCardiopulmonary Rehabil Prev , vol.32 , Issue.5 , pp. 284-291
    • Turner, L.J.1    Houchen, L.2    Williams, J.3    Singh, S.J.4
  • 10
    • 84863534837 scopus 로고    scopus 로고
    • Validity of activity monitors in health and chronic disease: a systematic review
    • Van Reemortel H., Giavedoni S., Raste Y., et al. Validity of activity monitors in health and chronic disease: a systematic review. Int J Behav Nutr Phys Act 2012, 9:84.
    • (2012) Int J Behav Nutr Phys Act , vol.9 , pp. 84
    • Van Reemortel, H.1    Giavedoni, S.2    Raste, Y.3
  • 11
    • 34547492896 scopus 로고    scopus 로고
    • Activity monitoring and energy expenditure in COPD patients: a validation study
    • Patel S.A., Benzo R.P., Slivka W.A., Sciurba F.C. Activity monitoring and energy expenditure in COPD patients: a validation study. COPD 2007, 4(2):107-112.
    • (2007) COPD , vol.4 , Issue.2 , pp. 107-112
    • Patel, S.A.1    Benzo, R.P.2    Slivka, W.A.3    Sciurba, F.C.4
  • 12
    • 80052675155 scopus 로고    scopus 로고
    • Properties of self-paced walking in chronic respiratory disease: a patient goal-oriented assessment
    • Evans R.A., Hill K., Dolmage T.E., et al. Properties of self-paced walking in chronic respiratory disease: a patient goal-oriented assessment. Chest 2011, 140(3):737-743.
    • (2011) Chest , vol.140 , Issue.3 , pp. 737-743
    • Evans, R.A.1    Hill, K.2    Dolmage, T.E.3
  • 13
    • 77953698249 scopus 로고    scopus 로고
    • Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease
    • Hill K., Dolmage T.E., Woon L., Goldstein R., Brooks D. Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease. Thorax 2010, 65(6):486-491.
    • (2010) Thorax , vol.65 , Issue.6 , pp. 486-491
    • Hill, K.1    Dolmage, T.E.2    Woon, L.3    Goldstein, R.4    Brooks, D.5
  • 14
    • 84862654624 scopus 로고    scopus 로고
    • Validity of six activity monitors in chronic obstructive pulmonary disease: a comparison with indirect calorimetry
    • Van Reemortel H., Raste Y., Louvaris Z., et al. Validity of six activity monitors in chronic obstructive pulmonary disease: a comparison with indirect calorimetry. PLoS One 2012, 7(6):e39198.
    • (2012) PLoS One , vol.7 , Issue.6
    • Van Reemortel, H.1    Raste, Y.2    Louvaris, Z.3
  • 15
    • 0027089979 scopus 로고
    • Development of a shuttle walking test of disability in patients with chronic airways obstruction
    • Singh S.J., Morgan M.D., Scott S., Walters D., Hardman A.E. Development of a shuttle walking test of disability in patients with chronic airways obstruction. Thorax 1992, 47(12):1019-1024.
    • (1992) Thorax , vol.47 , Issue.12 , pp. 1019-1024
    • Singh, S.J.1    Morgan, M.D.2    Scott, S.3    Walters, D.4    Hardman, A.E.5
  • 16
    • 84883247400 scopus 로고    scopus 로고
    • Can SenseWearTM activity monitors detect slow speeds of walking in patients with chronic obstructive pulmonary disease (COPD)?
    • Smith R.D., Sewell L., Cain O., Singh S.J., Morgan M.D.L. Can SenseWearTM activity monitors detect slow speeds of walking in patients with chronic obstructive pulmonary disease (COPD)?. Thorax 2007, 62.
    • (2007) Thorax , vol.62
    • Smith, R.D.1    Sewell, L.2    Cain, O.3    Singh, S.J.4    Morgan, M.D.L.5
  • 18
    • 76049112133 scopus 로고    scopus 로고
    • Step counting and energy expenditure estimation in patients with chronic obstructive pulmonary disease and healthy elderly: accuracy of 2 motion sensors
    • Furlanetto K.C., Bisca G.W., Oldemberg N., et al. Step counting and energy expenditure estimation in patients with chronic obstructive pulmonary disease and healthy elderly: accuracy of 2 motion sensors. Arch Phys Med Rehabil 2010, 91(2):261-267.
    • (2010) Arch Phys Med Rehabil , vol.91 , Issue.2 , pp. 261-267
    • Furlanetto, K.C.1    Bisca, G.W.2    Oldemberg, N.3
  • 19
    • 84858700360 scopus 로고    scopus 로고
    • Evaluation of activity monitors in controlled and free-living environments
    • Feito Y., Bassett D.R., Thompson D.L. Evaluation of activity monitors in controlled and free-living environments. Med Sci Sports Exerc 2012, 44(4):733-741.
    • (2012) Med Sci Sports Exerc , vol.44 , Issue.4 , pp. 733-741
    • Feito, Y.1    Bassett, D.R.2    Thompson, D.L.3
  • 20
    • 0027944968 scopus 로고
    • Comparison of oxygen uptake during a conventional treadmill test and the shuttle walking test in chronic airflow limitation
    • Singh S.J., Morgan M.D., Hardman A.E., Rowe C., Bardsley P.A. Comparison of oxygen uptake during a conventional treadmill test and the shuttle walking test in chronic airflow limitation. Eur Respir J 1994, 7(11):2016-2020.
    • (1994) Eur Respir J , vol.7 , Issue.11 , pp. 2016-2020
    • Singh, S.J.1    Morgan, M.D.2    Hardman, A.E.3    Rowe, C.4    Bardsley, P.A.5
  • 21
    • 58149398535 scopus 로고    scopus 로고
    • Efficacy of a cell phone-based exercise programme for COPD
    • Liu W.T., Wang C.H., Lin H.C., et al. Efficacy of a cell phone-based exercise programme for COPD. Eur Respir J 2008, 32(3):651-659.
    • (2008) Eur Respir J , vol.32 , Issue.3 , pp. 651-659
    • Liu, W.T.1    Wang, C.H.2    Lin, H.C.3
  • 22
    • 80053448209 scopus 로고    scopus 로고
    • Validity of instruments to measure physical activity may be questionable due to a lack of conceptual frameworks: a systematic review
    • Gimeno-Santos E., Frei A., Dobbels F., Rudell K., Puhan M.A., Garcia-Aymerich J. Validity of instruments to measure physical activity may be questionable due to a lack of conceptual frameworks: a systematic review. Health Qual Life Outcomes 2011, 9:86.
    • (2011) Health Qual Life Outcomes , vol.9 , pp. 86
    • Gimeno-Santos, E.1    Frei, A.2    Dobbels, F.3    Rudell, K.4    Puhan, M.A.5    Garcia-Aymerich, J.6
  • 23
    • 0032985897 scopus 로고    scopus 로고
    • The endurance shuttle walk: a new field test for the assessment of endurance capacity in chronic obstructive pulmonary disease
    • Revill S.M., Morgan M.D., Singh S.J., Williams J., Hardman A.E. The endurance shuttle walk: a new field test for the assessment of endurance capacity in chronic obstructive pulmonary disease. Thorax 1999, 54(3):213-222.
    • (1999) Thorax , vol.54 , Issue.3 , pp. 213-222
    • Revill, S.M.1    Morgan, M.D.2    Singh, S.J.3    Williams, J.4    Hardman, A.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.