메뉴 건너뛰기




Volumn 70, Issue 3, 2013, Pages 657-663

Ultra-fast steady state free precession and its application to in vivo 1H morphological and functional lung imaging at 1.5 tesla

Author keywords

imaging; lung; SSFP; steady state; ultra fast

Indexed keywords

BIOLOGICAL ORGANS; IMAGING TECHNIQUES;

EID: 84883229895     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24858     Document Type: Article
Times cited : (55)

References (22)
  • 1
    • 0000369227 scopus 로고
    • Steady-state free precession in nuclear magnetic resonance
    • Carr HY,. Steady-state free precession in nuclear magnetic resonance. Phys Rev 1958; 112: 1693-1701.
    • (1958) Phys Rev , vol.112 , pp. 1693-1701
    • Carr, H.Y.1
  • 3
    • 0025985527 scopus 로고
    • Spoiling of transverse magnetization in steady-state sequences
    • Zur Y, Wood ML, Neuringer LJ,. Spoiling of transverse magnetization in steady-state sequences. Magn Reson Med 1991; 21: 251-263.
    • (1991) Magn Reson Med , vol.21 , pp. 251-263
    • Zur, Y.1    Wood, M.L.2    Neuringer, L.J.3
  • 4
    • 0023796624 scopus 로고
    • Elimination of transverse coherences in FLASH MRI
    • Crawley AP, Wood ML, Henkelman RM,. Elimination of transverse coherences in FLASH MRI. Magn Reson Med 1988; 8: 248-260.
    • (1988) Magn Reson Med , vol.8 , pp. 248-260
    • Crawley, A.P.1    Wood, M.L.2    Henkelman, R.M.3
  • 5
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S,. Principles and applications of balanced SSFP techniques. Eur Radiol 2003; 13: 2409-2418.
    • (2003) Eur Radiol , vol.13 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 8
    • 0032588876 scopus 로고    scopus 로고
    • Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times
    • Stock KW, Chen Q, Hatabu H, Edelman RR,. Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times. Magn Reson Imaging 1999; 17: 997-1000.
    • (1999) Magn Reson Imaging , vol.17 , pp. 997-1000
    • Stock, K.W.1    Chen, Q.2    Hatabu, H.3    Edelman, R.R.4
  • 9
    • 0032587625 scopus 로고    scopus 로고
    • T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging
    • Hatabu H, Alsop DC, Listerud J, Bonnet M, Gefter WB,. T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging. Eur J Radiol 1999; 29: 245-252.
    • (1999) Eur J Radiol , vol.29 , pp. 245-252
    • Hatabu, H.1    Alsop, D.C.2    Listerud, J.3    Bonnet, M.4    Gefter, W.B.5
  • 10
    • 0025876984 scopus 로고
    • Lung parenchyma: Projection reconstruction MR imaging
    • Bergin CJ, Pauly JM, Macovski A,. Lung parenchyma: projection reconstruction MR imaging. Radiology 1991; 179: 777-781.
    • (1991) Radiology , vol.179 , pp. 777-781
    • Bergin, C.J.1    Pauly, J.M.2    MacOvski, A.3
  • 13
    • 60749128436 scopus 로고    scopus 로고
    • Lung morphology assessment using MRI: A robust ultra-short TR/TE 2D steady state free precession sequence used in cystic fibrosis patients
    • Failo R, Wielopolski PA, Tiddens HA, Hop WC, Mucelli RP, Lequin MH,. Lung morphology assessment using MRI: a robust ultra-short TR/TE 2D steady state free precession sequence used in cystic fibrosis patients. Magn Reson Med 2009; 61: 299-306.
    • (2009) Magn Reson Med , vol.61 , pp. 299-306
    • Failo, R.1    Wielopolski, P.A.2    Tiddens, H.A.3    Hop, W.C.4    Mucelli, R.P.5    Lequin, M.H.6
  • 17
    • 80051944922 scopus 로고    scopus 로고
    • Ventilation/perfusion imaging of the lung using ultra-short echo time (UTE) MRI in an animal model of pulmonary embolism
    • Togao O, Ohno Y, Dimitrov I, Hsia CC, Takahashi M,. Ventilation/perfusion imaging of the lung using ultra-short echo time (UTE) MRI in an animal model of pulmonary embolism. J Magn Reson Imaging 2011; 34: 539-546.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 539-546
    • Togao, O.1    Ohno, Y.2    Dimitrov, I.3    Hsia, C.C.4    Takahashi, M.5
  • 18
    • 34250345248 scopus 로고    scopus 로고
    • Short data-acquisition times improve projection images of lung tissue
    • Kuethe DO, Adolphi NL, Fukushima E,. Short data-acquisition times improve projection images of lung tissue. Magn Reson Med 2007; 57: 1058-1064.
    • (2007) Magn Reson Med , vol.57 , pp. 1058-1064
    • Kuethe, D.O.1    Adolphi, N.L.2    Fukushima, E.3
  • 20
    • 0027216325 scopus 로고
    • Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI
    • McGibney G, Smith MR, Nichols ST, Crawley A,. Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med 1993; 30: 51-59.
    • (1993) Magn Reson Med , vol.30 , pp. 51-59
    • McGibney, G.1    Smith, M.R.2    Nichols, S.T.3    Crawley, A.4
  • 22
    • 0037311485 scopus 로고    scopus 로고
    • Is TrueFISP a gradient-echo or a spin-echo sequence?
    • Scheffler K, Hennig J,. Is TrueFISP a gradient-echo or a spin-echo sequence? Magn Reson Med 2003; 49: 395-397.
    • (2003) Magn Reson Med , vol.49 , pp. 395-397
    • Scheffler, K.1    Hennig, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.