Volumn 76, Issue , 2013, Pages 307-313

Validation of the method for determination of the thermal resistance of fouling in shell and tube heat exchangers

Author keywords

Energy saving; Fouling determination; Heat exchanger fouling; Heat recovery; Shell and tube heat exchanger

Indexed keywords

CALCULATION ALGORITHMS; CRUDE DISTILLATION UNITS; HEAT EXCHANGER FOULING; HEAT EXCHANGER NETWORK; ON-LINE DETERMINATION; OPERATING PARAMETERS; QUALITATIVE EVALUATIONS; SHELL AND TUBE HEAT EXCHANGERS;

EID: 84883200471     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2013.07.052     Document Type: Article
Times cited : (31)

References (14)
  • 1
    • 10444259732 scopus 로고    scopus 로고
    • Optimal cleaning schedule for heat exchangers in a HEN
    • M. Markowski, and K. Urbaniec Optimal cleaning schedule for heat exchangers in a HEN Appl Therm Eng 25 2005 1019 1032
    • (2005) Appl Therm Eng , vol.25 , pp. 1019-1032
    • Markowski, M.1    Urbaniec, K.2
  • 2
    • 84883166308 scopus 로고    scopus 로고
    • Heat exchanger tube insert - An update in new application with trouble shooting aspects in crude unit, residue service, reboilers, U tubes
    • Germany, Kloster Irsee
    • Krueger A, Pouponnot F. Heat exchanger tube insert - an update in new application with trouble shooting aspects in crude unit, residue service, reboilers, U tubes. In: Proc ECI conf heat exchanger fouling and cleaning - challenges and opportunities, Germany, Kloster Irsee; 2005.
    • (2005) Proc ECI Conf Heat Exchanger Fouling and Cleaning - Challenges and Opportunities
    • Krueger, A.1    Pouponnot, F.2
  • 5
    • 80053313365 scopus 로고    scopus 로고
    • Fouling thresholds in bare tubes and tubes fitted with inserts
    • M. Yang, and B. Crittenden Fouling thresholds in bare tubes and tubes fitted with inserts Appl Energy 89 2012 67 73
    • (2012) Appl Energy , vol.89 , pp. 67-73
    • Yang, M.1    Crittenden, B.2
  • 6
    • 78650700218 scopus 로고    scopus 로고
    • Optimum cleaning cycles for heat transfer equipment undergoing fouling and ageing
    • E.M. Ishiyama, W.R. Paterson, and D.I. Wilson Optimum cleaning cycles for heat transfer equipment undergoing fouling and ageing Chem Eng Sci 66 2011 604 612
    • (2011) Chem Eng Sci , vol.66 , pp. 604-612
    • Ishiyama, E.M.1    Paterson, W.R.2    Wilson, D.I.3
  • 7
    • 33749651967 scopus 로고    scopus 로고
    • Supervision of the thermal performance of heat exchanger trains
    • C.O.R. Negrao, P.C. Tonin, and M. Madi Supervision of the thermal performance of heat exchanger trains Appl Thermal Eng 27 2007 347 357
    • (2007) Appl Thermal Eng , vol.27 , pp. 347-357
    • Negrao, C.O.R.1    Tonin, P.C.2    Madi, M.3
  • 10
    • 33746614096 scopus 로고    scopus 로고
    • Determination of mass balance for a process plant by the use of data reconciliation method
    • [in Polish]
    • M. Markowski, and M. Trafczyński Determination of mass balance for a process plant by the use of data reconciliation method Chem Process Eng 26 2005 51 66 [in Polish]
    • (2005) Chem Process Eng , vol.26 , pp. 51-66
    • Markowski, M.1    Trafczyński, M.2
  • 12
    • 0007647534 scopus 로고
    • Temperature distribution and heat exchange in multipass shell and tube exchangers with baffles
    • E.S. Gaddis, and E.U. Schlünder Temperature distribution and heat exchange in multipass shell and tube exchangers with baffles Heat Transfer Eng 1 1979 43 52
    • (1979) Heat Transfer Eng , vol.1 , pp. 43-52
    • Gaddis, E.S.1    Schlünder, E.U.2
  • 14
    • 21644436186 scopus 로고    scopus 로고
    • Prediction of heat transfer correlations for compact heat exchangers
    • Taler D., Prediction of heat transfer correlations for compact heat exchangers, Forschung im Ingenieurwesen
    • (2005) Forschung im Ingenieurwesen , vol.69 , pp. 137-150
    • Taler, D.1