메뉴 건너뛰기




Volumn , Issue , 2012, Pages 3179-3182

Performance assessment and optimization of Pulse Wave Imaging (PWI) in ex vivo canine aortas and in vivo normal human arteries

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA; ARTERIAL PULSE; BEAM DENSITY; BEAM SWEEPING; CANINE AORTA; CARDIAC CYCLES; CAROTID ARTERY; COMPENSATION SCHEME; DICROTIC NOTCH; EX-VIVO; FEATURE-TRACKING; FRAME RATE; HUMAN ARTERY; IN-VIVO; INFLECTION POINTS; MORPHOLOGICAL CHANGES; MULTIPLE WALLS; OPTIMAL PARAMETER; PERFORMANCE ASSESSMENT AND OPTIMIZATION; PROCESSING METHOD; PULSE WAVE; PULSE WAVE VELOCITY; REFLECTED WAVES; SALIENT FEATURES; SPATIAL RESOLUTION; SPATIO-TEMPORAL VARIATION; TEMPORAL RESOLUTION; VESSEL WALL MOTION; WALL MOTION; WAVE FORMS;

EID: 84882970625     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2012.6346640     Document Type: Conference Paper
Times cited : (5)

References (13)
  • 3
    • 33749026111 scopus 로고    scopus 로고
    • Pulse wave analysis and pulse wave velocity A review of blood pressure interpretation 100 years after korotkov
    • K. Hirata, M. Kawakami, M.F. O'Rourke. (2006). Pulse Wave Analysis and Pulse Wave Velocity A Review of Blood Pressure Interpretation 100 Years After Korotkov. Circ J, 70, 1231-1239.
    • (2006) Circ J , vol.70 , pp. 1231-1239
    • Hirata, K.1    Kawakami, M.2    O'Rourke, M.F.3
  • 4
    • 75449092277 scopus 로고    scopus 로고
    • Arterial blood pressure measurement and pulse wave analysis - Their role in enhancing cardiovascular assessment
    • A.P. Avolio, M. Butlin, and A. Walsh. (2010). Arterial blood pressure measurement and pulse wave analysis - their role in enhancing cardiovascular assessment. Physiol. Meas., 31, R1-R47.
    • (2010) Physiol. Meas. , vol.31
    • Avolio, A.P.1    Butlin, M.2    Walsh, A.3
  • 6
    • 0036293405 scopus 로고    scopus 로고
    • Pulse-wave velocity measured in one heartbeat using MR tagging
    • Macgowan, C. K., Henkelman, R. M., & Wood, M. L. (2002). Pulse-wave velocity measured in one heartbeat using MR tagging. Magnetic resonance in medicine, 48(1), 115-21.
    • (2002) Magnetic Resonance in Medicine , vol.48 , Issue.1 , pp. 115-121
    • Macgowan, C.K.1    Henkelman, R.M.2    Wood, M.L.3
  • 7
    • 37349126923 scopus 로고    scopus 로고
    • A novel noninvasive technique for pulse-wave imaging and characterization of clinically-significant vascular mechanical properties in vivo
    • Fujikura, K., Luo, J., Gamarnik, V., Pernot, M., Fukumoto, R., Tilson, M. D., & Konofagou, E. E. (2007). A novel noninvasive technique for pulse-wave imaging and characterization of clinically-significant vascular mechanical properties in vivo. Ultrasonic imaging, 29(3), 137-54.
    • (2007) Ultrasonic Imaging , vol.29 , Issue.3 , pp. 137-154
    • Fujikura, K.1    Luo, J.2    Gamarnik, V.3    Pernot, M.4    Fukumoto, R.5    Tilson, M.D.6    Konofagou, E.E.7
  • 9
    • 77949654916 scopus 로고    scopus 로고
    • Pulse wave imaging for noninvasive and quantitative measurement of arterial stiffness in vivo
    • Vappou, J., Luo, J., & Konofagou, E. E. (2010). Pulse wave imaging for noninvasive and quantitative measurement of arterial stiffness in vivo. Am J Hypertens, 23(4), 393-8.
    • (2010) Am J Hypertens , vol.23 , Issue.4 , pp. 393-398
    • Vappou, J.1    Luo, J.2    Konofagou, E.E.3
  • 10
    • 77953257554 scopus 로고    scopus 로고
    • A fast Normalized cross-correlation calculation method for motion estimation
    • Luo, J., & Konofagou, E. (2010). A fast normalized cross-correlation calculation method for motion estimation. IEEE Trans UFFC, 57(6), 1347-57.
    • (2010) IEEE Trans UFFC , vol.57 , Issue.6 , pp. 1347-1357
    • Luo, J.1    Konofagou, E.2
  • 12
    • 84870832541 scopus 로고    scopus 로고
    • Pulse wave imaging (PWI) of the human carotid artery: An in vivo feasibility study
    • Luo, J., Li, R., & Konofagou, E. (2012). Pulse Wave Imaging (PWI) of the human carotid artery: An in vivo feasibility study. The Journal of the Acoustical Society of America, 131(4), 3289.
    • (2012) The Journal of the Acoustical Society of America , vol.131 , Issue.4 , pp. 3289
    • Luo, J.1    Li, R.2    Konofagou, E.3
  • 13
    • 34247527823 scopus 로고    scopus 로고
    • Measurement of local pulse wave velocity: Effects of signal processing on precision
    • Hermeling, E., Reesink, K. D., Reneman, R. S., & Hoeks, A. P. G. (2007). Measurement of local pulse wave velocity: effects of signal processing on precision. Ultrasound in medicine & biology, 33(5), 774-81.
    • (2007) Ultrasound in Medicine & Biology , vol.33 , Issue.5 , pp. 774-781
    • Hermeling, E.1    Reesink, K.D.2    Reneman, R.S.3    Hoeks, A.P.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.