-
1
-
-
0034190334
-
Influence of trunk flexion on biomechanics of wheelchair propulsion
-
M.M. Rodgers, R.E. Keyser, E.R. Gardner, P.J. Russell, and P.H. Gorman Influence of trunk flexion on biomechanics of wheelchair propulsion J Rehabil Res Dev 37 2000 283 295
-
(2000)
J Rehabil Res Dev
, vol.37
, pp. 283-295
-
-
Rodgers, M.M.1
Keyser, R.E.2
Gardner, E.R.3
Russell, P.J.4
Gorman, P.H.5
-
2
-
-
0034526145
-
Factors associated with thoracic spinal cord injury, lesion level and rotator cuff disorders
-
K.A. Sinnott, P. Milburn, and H. McNaughton Factors associated with thoracic spinal cord injury, lesion level and rotator cuff disorders Spinal Cord 38 2000 748 753
-
(2000)
Spinal Cord
, vol.38
, pp. 748-753
-
-
Sinnott, K.A.1
Milburn, P.2
McNaughton, H.3
-
3
-
-
84882643865
-
Wheelchairs
-
J.A. DeLisa, B.M. Gans, N.E. Walsh, Lippincott Williams & Wilkins
-
M.L. Boninger, R.A. Cooper, M. Schmeler, and R. Cooper Wheelchairs J.A. DeLisa, B.M. Gans, N.E. Walsh, Physical medicine and rehabilitation: principles and practice vol. 1. Philadelphia: 2005 Lippincott Williams & Wilkins 1289 1306
-
(2005)
Physical Medicine and Rehabilitation: Principles and Practice
, vol.1 PHILADELPHIA
, pp. 1289-1306
-
-
Boninger, M.L.1
Cooper, R.A.2
Schmeler, M.3
Cooper, R.4
-
6
-
-
7244242234
-
Targeting recovery: Priorities of the spinal cord-injured population
-
K.D. Anderson Targeting recovery: priorities of the spinal cord-injured population J Neurotrauma 21 2004 1371 1383
-
(2004)
J Neurotrauma
, vol.21
, pp. 1371-1383
-
-
Anderson, K.D.1
-
7
-
-
33746216221
-
Feasibility of a neuroprosthesis for the control of seated posture after spinal cord injury with functional electrical stimulation: A simulation study
-
A.J. Wilkenfeld, M.L. Audu, and R.J. Triolo Feasibility of a neuroprosthesis for the control of seated posture after spinal cord injury with functional electrical stimulation: a simulation study J Rehabil Res Dev 43 2006 139 152
-
(2006)
J Rehabil Res Dev
, vol.43
, pp. 139-152
-
-
Wilkenfeld, A.J.1
Audu, M.L.2
Triolo, R.J.3
-
8
-
-
70349243232
-
A musculoskeletal model of the trunk and hips for the development of a seated posture-control neuroprosthesis
-
J. Lambrecht, M. Audu, R. Triolo, and R. Kirsch A musculoskeletal model of the trunk and hips for the development of a seated posture-control neuroprosthesis J Rehabil Res Dev 46 2009 515 528
-
(2009)
J Rehabil Res Dev
, vol.46
, pp. 515-528
-
-
Lambrecht, J.1
Audu, M.2
Triolo, R.3
Kirsch, R.4
-
9
-
-
69449085944
-
Biomechanical analysis of surface electrical stimulation on the trunk musculature during wheelchair propulsion
-
Y. Yang, A. Koontz, and R. Triolo Biomechanical analysis of surface electrical stimulation on the trunk musculature during wheelchair propulsion Neurorehabil Neural Repair 23 2009 717 725
-
(2009)
Neurorehabil Neural Repair
, vol.23
, pp. 717-725
-
-
Yang, Y.1
Koontz, A.2
Triolo, R.3
-
10
-
-
2942655730
-
The effects of trunk stimulation on bimanual seated workspace
-
S. Kukke, and R.J. Triolo The effects of trunk stimulation on bimanual seated workspace IEEE Trans Neural Syst Rehabil Eng 12 2004 117 185
-
(2004)
IEEE Trans Neural Syst Rehabil Eng
, vol.12
, pp. 117-185
-
-
Kukke, S.1
Triolo, R.J.2
-
11
-
-
60349108078
-
Implanted electrical stimulation of the trunk for seated postural stability and functional mobility after cervical SCI: A single case study
-
R.J. Triolo, L. Boggs, M. Miller, J. Nagy, G. Nemuanitis, and S. Nogan-Bailey Implanted electrical stimulation of the trunk for seated postural stability and functional mobility after cervical SCI: a single case study Arch Phys Med Rehabil 90 2009 340 347
-
(2009)
Arch Phys Med Rehabil
, vol.90
, pp. 340-347
-
-
Triolo, R.J.1
Boggs, L.2
Miller, M.3
Nagy, J.4
Nemuanitis, G.5
Nogan-Bailey, S.6
-
12
-
-
0023378409
-
An externally powered, multichannel implantable stimulator for versatile control of paralyzed muscle
-
B. Smith, P.H. Peckham, M.W. Keith, and D.D. Roscoe An externally powered, multichannel implantable stimulator for versatile control of paralyzed muscle IEEE Trans Biomed Eng 34 1987 499 508
-
(1987)
IEEE Trans Biomed Eng
, vol.34
, pp. 499-508
-
-
Smith, B.1
Peckham, P.H.2
Keith, M.W.3
Roscoe, D.D.4
-
13
-
-
0035708730
-
Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers - Where do we stand?
-
J.A. Davis, R.J. Triolo, and J. Uhlir Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers - where do we stand? J Rehabil Res Dev 38 2001 609 617
-
(2001)
J Rehabil Res Dev
, vol.38
, pp. 609-617
-
-
Davis, J.A.1
Triolo, R.J.2
Uhlir, J.3
-
14
-
-
84860226957
-
Longitudinal performance of a surgically implanted neuroprosthesis for lower extremity exercise, standing, and transfers after spinal cord injury
-
R.J. Triolo, S.N. Bailey, and M.E. Miller Longitudinal performance of a surgically implanted neuroprosthesis for lower extremity exercise, standing, and transfers after spinal cord injury Arch Phys Med Rehabil 93 2012 896 904
-
(2012)
Arch Phys Med Rehabil
, vol.93
, pp. 896-904
-
-
Triolo, R.J.1
Bailey, S.N.2
Miller, M.E.3
-
15
-
-
34548230407
-
New functional neuromuscular stimulation approaches to standing and walking
-
V.K. Mushahwar, P.L. Jacobs, R.A. Normann, R.J. Triolo, and N. Kleitman New functional neuromuscular stimulation approaches to standing and walking J Neural Eng 4 2007 S181 S197
-
(2007)
J Neural Eng
, vol.4
-
-
Mushahwar, V.K.1
Jacobs, P.L.2
Normann, R.A.3
Triolo, R.J.4
Kleitman, N.5
-
16
-
-
0032053980
-
An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle
-
B. Smith, Z. Tang, and M.W. Johnson An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle IEEE Trans Biomed Eng 45 1998 463 475
-
(1998)
IEEE Trans Biomed Eng
, vol.45
, pp. 463-475
-
-
Smith, B.1
Tang, Z.2
Johnson, M.W.3
-
17
-
-
84860503334
-
Comparing joint kinematics and center of mass acceleration as feedback for control of standing balance by functional neuromuscular stimulation
-
R. Nataraj, M. Audu, and R. Triolo Comparing joint kinematics and center of mass acceleration as feedback for control of standing balance by functional neuromuscular stimulation J Neuroeng Rehabil 9 2012 25
-
(2012)
J Neuroeng Rehabil
, vol.9
, pp. 25
-
-
Nataraj, R.1
Audu, M.2
Triolo, R.3
-
18
-
-
84859097998
-
Trunk acceleration for neuroprosthetic control of standing - A pilot study
-
R. Nataraj, M. Audu, R. Kirsch, and R. Triolo Trunk acceleration for neuroprosthetic control of standing - a pilot study J Appl Biomech 28 2012 85 92
-
(2012)
J Appl Biomech
, vol.28
, pp. 85-92
-
-
Nataraj, R.1
Audu, M.2
Kirsch, R.3
Triolo, R.4
-
19
-
-
55749084051
-
Standing after spinal cord injury with four contact nerve-cuff electrodes for quadriceps stimulation
-
L. Fisher, M. Miller, and S. Nogan Standing after spinal cord injury with four contact nerve-cuff electrodes for quadriceps stimulation IEEE Trans Neural Syst Rehabil Eng 16 2008 473 478
-
(2008)
IEEE Trans Neural Syst Rehabil Eng
, vol.16
, pp. 473-478
-
-
Fisher, L.1
Miller, M.2
Nogan, S.3
-
20
-
-
70349776550
-
Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve
-
L.R. Fisher, D.J. Tyler, J.S. Anderson, and R.J. Triolo Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve J Neural Eng 6 2009 046010
-
(2009)
J Neural Eng
, vol.6
, pp. 046010
-
-
Fisher, L.R.1
Tyler, D.J.2
Anderson, J.S.3
Triolo, R.J.4
-
21
-
-
0028443013
-
A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system
-
W.D. Memberg, P.H. Peckham, and M.W. Keith A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system IEEE Trans Biomed Eng 2 1994 80 91
-
(1994)
IEEE Trans Biomed Eng
, vol.2
, pp. 80-91
-
-
Memberg, W.D.1
Peckham, P.H.2
Keith, M.W.3
-
22
-
-
0035085876
-
Surgical technique for installing an 8-channel neuroprosthesis for standing
-
J.A. Davis, R.J. Triolo, and J.P. Uhlir Surgical technique for installing an 8-channel neuroprosthesis for standing Clin Orthop Relat Res 4 2001 237 252
-
(2001)
Clin Orthop Relat Res
, vol.4
, pp. 237-252
-
-
Davis, J.A.1
Triolo, R.J.2
Uhlir, J.P.3
-
23
-
-
0031913657
-
Implantation of a 16-channel functional electrical stimulation walking system
-
M. Sharma, E.B. Marsolais, and G. Polando Implantation of a 16-channel functional electrical stimulation walking system Clin Orthop Relat Res 347 1998 236 242
-
(1998)
Clin Orthop Relat Res
, vol.347
, pp. 236-242
-
-
Sharma, M.1
Marsolais, E.B.2
Polando, G.3
-
24
-
-
0031170788
-
Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes
-
J.M. Akers, P.H. Peckham, M.W. Keith, and K. Merritt Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes IEEE Trans Rehabil Eng 5 1996 207 220
-
(1996)
IEEE Trans Rehabil Eng
, vol.5
, pp. 207-220
-
-
Akers, J.M.1
Peckham, P.H.2
Keith, M.W.3
Merritt, K.4
-
25
-
-
2942673164
-
Performance of epimysial stimulating electrodes in the lower extremities of individuals with spinal cord injury
-
J.P. Uhlir, R.J. Triolo, J.A. Davis, and C. Bieri Performance of epimysial stimulating electrodes in the lower extremities of individuals with spinal cord injury IEEE Trans Rehabil Eng 12 2004 279 287
-
(2004)
IEEE Trans Rehabil Eng
, vol.12
, pp. 279-287
-
-
Uhlir, J.P.1
Triolo, R.J.2
Davis, J.A.3
Bieri, C.4
-
26
-
-
84882872954
-
-
U.S. Department of Justice and U.S. Department of Transportation Accessed January 30
-
U.S. Department of Justice and U.S. Department of Transportation. ADA accessibility guidelines for buildings and facilities. Available at: http://www.access-board.gov/adaag/html/adaag.htm. Accessed January 30, 2012.
-
(2012)
ADA Accessibility Guidelines for Buildings and Facilities
-
-
-
29
-
-
0002615419
-
Statistical analyses for single-case experimental designs
-
D.H. Barlow, M. Hersen, 2nd ed. Pergamon Pr New York
-
A.E. Kazdin Statistical analyses for single-case experimental designs D.H. Barlow, M. Hersen, Single case experimental designs 2nd ed. 1984 Pergamon Pr New York 285 324
-
(1984)
Single Case Experimental Designs
, pp. 285-324
-
-
Kazdin, A.E.1
-
30
-
-
84882868114
-
Group experimental designs
-
O.D. Payton, M.S. Sullivan, 2nd ed. FA Davis Philadelphia
-
O.D. Payton Group experimental designs O.D. Payton, M.S. Sullivan, Research: the validation of clinical practice 2nd ed. 1989 FA Davis Philadelphia 142 156
-
(1989)
Research: The Validation of Clinical Practice
, pp. 142-156
-
-
Payton, O.D.1
-
32
-
-
0019162193
-
Trunk strengths in attempted flexion, extension and lateral bending in healthy subjects and patients with low-back disorders
-
T. McNeill, D. Warwick, G. Anderson, and A. Schultz Trunk strengths in attempted flexion, extension and lateral bending in healthy subjects and patients with low-back disorders Spine (Phila Pa 1976) 6 1980 529 538
-
(1980)
Spine (Phila Pa 1976)
, vol.6
, pp. 529-538
-
-
McNeill, T.1
Warwick, D.2
Anderson, G.3
Schultz, A.4
-
34
-
-
0024523142
-
A database of isoinertial trunk strength test against three resistance levels in sagittal, frontal and transverse in normal male subjects
-
M. Parnianpour, F. Li, M. Nordin, and N. Kahanovits A database of isoinertial trunk strength test against three resistance levels in sagittal, frontal and transverse in normal male subjects Spine (Phila Pa 1976) 14 1989 409 411
-
(1989)
Spine (Phila Pa 1976)
, vol.14
, pp. 409-411
-
-
Parnianpour, M.1
Li, F.2
Nordin, M.3
Kahanovits, N.4
-
36
-
-
33748697621
-
Torque and EMG in rotation extension of the torso from pre-rotated and flexed postures
-
S. Kumar, and Y. Narayan Torque and EMG in rotation extension of the torso from pre-rotated and flexed postures Clin Biomech (Bristol, Avon) 21 2006 920 931
-
(2006)
Clin Biomech (Bristol, Avon)
, vol.21
, pp. 920-931
-
-
Kumar, S.1
Narayan, Y.2
-
37
-
-
29744433684
-
Model and in vivo studies on human trunk load partitioning and stability in isometric forward flexions
-
N. Arjmand, and A. Shirazi-Adl Model and in vivo studies on human trunk load partitioning and stability in isometric forward flexions J Biomech 39 2006 510 521
-
(2006)
J Biomech
, vol.39
, pp. 510-521
-
-
Arjmand, N.1
Shirazi-Adl, A.2
-
39
-
-
84887319705
-
Physiological impact of neuromuscular electrical stimulation on trunk stability
-
G. Nemunaitis, R. Triolo, and L. Boggs Physiological impact of neuromuscular electrical stimulation on trunk stability J Spinal Cord Med 32 2009 468
-
(2009)
J Spinal Cord Med
, vol.32
, pp. 468
-
-
Nemunaitis, G.1
Triolo, R.2
Boggs, L.3
|