Volumn , Issue , 2012, Pages 496-500

EEG eye blink artifact removal by EOG modeling and Kalman filter

Author keywords

Electroencephalography; EOG modeling; Eye blink; Kalman filter; Ocular artifact

Indexed keywords

AUTO REGRESSIVE MODELS; DISTORTION METRICS; ELECTROENCEPHALOGRAM SIGNALS; EYE BLINK; EYE-BLINK ARTIFACT REMOVALS; EYE-BLINK ARTIFACTS; OCULAR ARTIFACTS; REFERENCE ELECTRODES;

EID: 84882701555     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BMEI.2012.6513162     Document Type: Conference Paper
Times cited : (28)

References (15)
  • 1
    • 33745749040 scopus 로고    scopus 로고
    • Robust adaptive techniques for minimization of EOG artefacts from EEG signals
    • S. Puthusserypady, T. Ratnarajah, "Robust adaptive techniques for minimization of EOG artefacts from EEG signals," Signal processing, vol. 86, no. 9, pp. 2351-2363, 2006.
    • (2006) Signal Processing , vol.86 , Issue.9 , pp. 2351-2363
    • Puthusserypady, S.1    Ratnarajah, T.2
  • 3
    • 0034144007 scopus 로고    scopus 로고
    • Removal of ocular artifact from the EEG: A review
    • R. J. Croft and R. J. Barry, "Removal of ocular artifact from the EEG: a review," Neurophysiol. Clin., vol. 30, no. 1, pp. 5-19, 2000.
    • (2000) Neurophysiol. Clin. , vol.30 , Issue.1 , pp. 5-19
    • Croft, R.J.1    Barry, R.J.2
  • 4
    • 2942720395 scopus 로고    scopus 로고
    • Removal of ocular artifacts from electro-encephalogram by adaptive filtering
    • P. He, G. Wilson, and C. Russell, "Removal of ocular artifacts from electro-encephalogram by adaptive filtering," Medical and biological engineering and computing, vol. 42, no. 3, pp. 407-412, 2004.
    • (2004) Medical and Biological Engineering and Computing , vol.42 , Issue.3 , pp. 407-412
    • He, P.1    Wilson, G.2    Russell, C.3
  • 6
    • 84864220328 scopus 로고    scopus 로고
    • Online removal of eye movement and blink eeg artifacts using a high speed eye tracker
    • B. Noureddin, P. D. Lawrence, and G. E. Birch, "Online Removal of Eye Movement and Blink EEG Artifacts Using a High Speed Eye Tracker," IEEE Transactions on Biomedical Engineering, vol. 59, no. 8, pp. 2103-2110, 2012.
    • (2012) IEEE Transactions on Biomedical Engineering , vol.59 , Issue.8 , pp. 2103-2110
    • Noureddin, B.1    Lawrence, P.D.2    Birch, G.E.3
  • 7
    • 34247580329 scopus 로고    scopus 로고
    • Removal of ocular artifacts from the EEG: A comparison between timedomain regression method and adaptive filtering method using simulated data
    • P. He, G. Wilson, C. Russell, and M. Gerschutz "Removal of ocular artifacts from the EEG: a comparison between timedomain regression method and adaptive filtering method using simulated data," Medical and biological engineering and computing, vol. 45, no. 4, pp. 495-503, 2007.
    • (2007) Medical and Biological Engineering and Computing , vol.45 , Issue.4 , pp. 495-503
    • He, P.1    Wilson, G.2    Russell, C.3    Gerschutz, M.4
  • 12
    • 0021822971 scopus 로고
    • Analysis of biomedical signals by means of linear modeling
    • B. H. Jansen, "Analysis of biomedical signals by means of linear modeling," Critical Reviews in Biomedical Engineering, vol. 12, no. 4, pp. 343-392, 1985.
    • (1985) Critical Reviews in Biomedical Engineering , vol.12 , Issue.4 , pp. 343-392
    • Jansen, B.H.1
  • 14
    • 0027371167 scopus 로고
    • Ocular artifacts in recording EEGs and even-related potentials II: Source dipoles and source components
    • O. G. Lins, T. W. Picton, P. Berg, and M. Scherg, "Ocular artifacts in recording EEGs and even-related potentials II: Source dipoles and source components," Brain Topography, vol. 6, no. 1, pp. 65-78, 1993.
    • (1993) Brain Topography , vol.6 , Issue.1 , pp. 65-78
    • Lins, O.G.1    Picton, T.W.2    Berg, P.3    Scherg, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.