메뉴 건너뛰기




Volumn 27, Issue 4, 2013, Pages 563-568

Chest anteroposterior diameter affects difficulty of laryngoscopy for non-morbidly obese patients

Author keywords

Diagnostic tests; Intratracheal intubation; Laryngoscopy

Indexed keywords

ADULT; AGED; ANTHROPOMETRIC PARAMETERS; AREA UNDER THE CURVE; ARTICLE; BED; CHEST ANTEROPOSTERIOR DIAMETER; DIAGNOSTIC ACCURACY; FEMALE; HEAD; HUMAN; LARYNGOSCOPY; LARYNX; MAJOR CLINICAL STUDY; MALE; OBESITY; OBSERVATIONAL STUDY; PROSPECTIVE STUDY; RECEIVER OPERATING CHARACTERISTIC; SURGICAL BED; THORAX;

EID: 84882623421     PISSN: 09138668     EISSN: 14388359     Source Type: Journal    
DOI: 10.1007/s00540-013-1572-1     Document Type: Article
Times cited : (5)

References (21)
  • 1
    • 0034785574 scopus 로고    scopus 로고
    • Randomized study comparing the "sniffing position" with simple head extension for laryngoscopic view in elective surgery patients
    • 11605921 10.1097/00000542-200110000-00009 1:STN:280: DC%2BD3MrmtVSksA%3D%3D
    • Adnet F, Baillard C, Borron SW, Denantes C, Lefebvre L, Galinski M, Martinez C, Cupa M, Lapostolle F. Randomized study comparing the "sniffing position" with simple head extension for laryngoscopic view in elective surgery patients. Anesthesiology. 2001;95:836-41.
    • (2001) Anesthesiology , vol.95 , pp. 836-841
    • Adnet, F.1    Baillard, C.2    Borron, S.W.3    Denantes, C.4    Lefebvre, L.5    Galinski, M.6    Martinez, C.7    Cupa, M.8    Lapostolle, F.9
  • 2
    • 79960274471 scopus 로고    scopus 로고
    • Head and neck position for direct laryngoscopy
    • El-Orbany M, Woehlck H, Salem MR. Head and neck position for direct laryngoscopy. Anesth Analg. 2011;113:03-9.
    • (2011) Anesth Analg , vol.113 , pp. 03-09
    • El-Orbany, M.1    Woehlck, H.2    Salem, M.R.3
  • 3
    • 0036728084 scopus 로고    scopus 로고
    • Comparison of intubating positions: The end point of for position should be measured
    • 12218549 10.1097/00000542-200209000-00036
    • Benumof JL. Comparison of intubating positions: the end point of for position should be measured. Anesthesiology. 2002;97:750.
    • (2002) Anesthesiology , vol.97 , pp. 750
    • Benumof, J.L.1
  • 4
    • 0036696129 scopus 로고    scopus 로고
    • Head and neck elevation beyond the sniffing position improves laryngeal view in cases of difficult direct laryngoscopy
    • 12208436 10.1016/S0952-8180(02)00368-9
    • Schmitt HJ, Mang H. Head and neck elevation beyond the sniffing position improves laryngeal view in cases of difficult direct laryngoscopy. J Clin Anesth. 2002;14:335-8.
    • (2002) J Clin Anesth , vol.14 , pp. 335-338
    • Schmitt, H.J.1    Mang, H.2
  • 5
    • 7644233191 scopus 로고    scopus 로고
    • Laryngoscopy and morbid obesity: A comparison of the "sniff" and "ramped" positions
    • 15527629 10.1381/0960892042386869
    • Collins JS, Lemmens HJ, Brodsky JB, Brock-Utne JG, Levitan RM. Laryngoscopy and morbid obesity: a comparison of the "sniff" and "ramped" positions. Obes Surg. 2004;14:1171-5.
    • (2004) Obes Surg , vol.14 , pp. 1171-1175
    • Collins, J.S.1    Lemmens, H.J.2    Brodsky, J.B.3    Brock-Utne, J.G.4    Levitan, R.M.5
  • 6
    • 0029909985 scopus 로고    scopus 로고
    • Effect of general anesthesia and paralysis on upper airway changes due to head position
    • 8873549 10.1097/00000542-199610000-00014 1:STN:280:DyaK2s%2FislCisg%3D%3D
    • Sivarajan M, Joy JV. Effect of general anesthesia and paralysis on upper airway changes due to head position. Anesthesiology. 1996;85:787-93.
    • (1996) Anesthesiology , vol.85 , pp. 787-793
    • Sivarajan, M.1    Joy, J.V.2
  • 7
    • 0023238545 scopus 로고
    • Difficult tracheal intubation: A retrospective study
    • 3592174 10.1111/j.1365-2044.1987.tb04039.x 1:STN:280:DyaL2s3jvFegtg%3D%3D
    • Samsoon GL, Young JR. Difficult tracheal intubation: a retrospective study. Anaesthesia. 1987;42:487-90.
    • (1987) Anaesthesia , vol.42 , pp. 487-490
    • Samsoon, G.L.1    Young, J.R.2
  • 8
    • 0028129324 scopus 로고
    • Prediction of difficult tracheal intubation
    • 7917726 10.1093/bja/73.2.149 1:STN:280:DyaK2M%2FgtFWmsg%3D%3D
    • Savva D. Prediction of difficult tracheal intubation. Br J Anaesth. 1994;73:149-53.
    • (1994) Br J Anaesth , vol.73 , pp. 149-153
    • Savva, D.1
  • 9
    • 59649122494 scopus 로고    scopus 로고
    • Diagnostic predictor of difficult laryngoscopy: The hyomental distance ratio
    • 19151285 10.1213/ane.0b013e31818fc347
    • Huh J, Shin HY, Kim SH, Yoon TK, Kim DK. Diagnostic predictor of difficult laryngoscopy: the hyomental distance ratio. Anesth Analg. 2009;108:544-8.
    • (2009) Anesth Analg , vol.108 , pp. 544-548
    • Huh, J.1    Shin, H.Y.2    Kim, S.H.3    Yoon, T.K.4    Kim, D.K.5
  • 10
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • 6507827 10.1111/j.1365-2044.1984.tb08932.x 1:STN:280: DyaL2M%2FntVWrtw%3D%3D
    • Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia. 1984;39:1105-11.
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 11
    • 0023710206 scopus 로고
    • Comparing the area under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • 3203132 10.2307/2531595 1:STN:280:DyaL1M%2Fns12ksQ%3D%3D
    • DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the area under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837-45.
    • (1988) Biometrics , vol.44 , pp. 837-845
    • Delong, E.R.1    Delong, D.M.2    Clarke-Pearson, D.L.3
  • 12
    • 77958183534 scopus 로고    scopus 로고
    • Changes in airway configuration with different head and neck positions using magnetic resonance imaging of normal airway: A new concept with possible clinical applications
    • 20846964 10.1093/bja/aeq239 1:STN:280:DC%2BC3cfpvFWlsg%3D%3D
    • Greenland KB, Edward MJ, Hutton NJ, Challis VJ, Irwin MG, Sleigh JW. Changes in airway configuration with different head and neck positions using magnetic resonance imaging of normal airway: a new concept with possible clinical applications. Br J Anaesth. 2010;105:683-90.
    • (2010) Br J Anaesth , vol.105 , pp. 683-690
    • Greenland, K.B.1    Edward, M.J.2    Hutton, N.J.3    Challis, V.J.4    Irwin, M.G.5    Sleigh, J.W.6
  • 13
    • 76749091189 scopus 로고    scopus 로고
    • External auditory meatus-sternal notch relationship in adults in the sniffing position: A magnetic resonance imaging study
    • 20086071 10.1093/bja/aep390 1:STN:280:DC%2BC3c%2FksVahsw%3D%3D
    • Greenland KB, Edward MJ, Hutton NJ. External auditory meatus-sternal notch relationship in adults in the sniffing position: a magnetic resonance imaging study. Br J Anaesth. 2010;104:268-9.
    • (2010) Br J Anaesth , vol.104 , pp. 268-269
    • Greenland, K.B.1    Edward, M.J.2    Hutton, N.J.3
  • 14
    • 0034790646 scopus 로고    scopus 로고
    • Common practice and concepts in anesthesia: Time for reassessment: Is the sniffing position a "gold standard" for laryngoscopy?
    • 11605919 10.1097/00000542-200110000-00007 1:STN:280: DC%2BD3MrmtVSksg%3D%3D
    • Isono S. Common practice and concepts in anesthesia: time for reassessment: is the sniffing position a "gold standard" for laryngoscopy? Anesthesiology. 2001;95:825-7.
    • (2001) Anesthesiology , vol.95 , pp. 825-827
    • Isono, S.1
  • 15
    • 36448975886 scopus 로고    scopus 로고
    • Dynamic interaction of craniofacial structures during head positioning and direct laryngoscopy in anesthetized patients with and without difficult laryngoscopy
    • 18043055 10.1097/01.anes.0000291439.52483.6a
    • Kitamura Y, Isono S, Suzuki N, Sato Y, Nishino T. Dynamic interaction of craniofacial structures during head positioning and direct laryngoscopy in anesthetized patients with and without difficult laryngoscopy. Anesthesiology. 2007;107:875-83.
    • (2007) Anesthesiology , vol.107 , pp. 875-883
    • Kitamura, Y.1    Isono, S.2    Suzuki, N.3    Sato, Y.4    Nishino, T.5
  • 16
    • 33744476117 scopus 로고    scopus 로고
    • A systemic review (meta-analysis) of the accuracy of the Mallampati tests to predict the difficult airway
    • 16717341 10.1213/01.ane.0000217211.12232.55
    • Lee A, Fan LT, Gin T, Karmakar MK, NganKee WD. A systemic review (meta-analysis) of the accuracy of the Mallampati tests to predict the difficult airway. Anesth Analg. 2006;102:1867-78.
    • (2006) Anesth Analg , vol.102 , pp. 1867-1878
    • Lee, A.1    Fan, L.T.2    Gin, T.3    Karmakar, M.K.4    Ngankee, W.D.5
  • 17
    • 0026350145 scopus 로고
    • Management of the difficult adult airway. With special emphasis on awake tracheal intubation
    • 1824555 10.1097/00000542-199111000-00041 1:STN:280:DyaK38%2FnsVKjtA%3D%3D
    • Benumof JL. Management of the difficult adult airway. With special emphasis on awake tracheal intubation. Anesthesiology. 1991;75:1087-110.
    • (1991) Anesthesiology , vol.75 , pp. 1087-1110
    • Benumof, J.L.1
  • 18
    • 0034104349 scopus 로고    scopus 로고
    • A new practical classification of laryngeal view
    • 10671848 10.1046/j.1365-2044.2000.01270.x 1:STN:280: DC%2BD3c7jslOmtg%3D%3D
    • Cook TM. A new practical classification of laryngeal view. Anaesthesia. 2000;55:274-9.
    • (2000) Anaesthesia , vol.55 , pp. 274-279
    • Cook, T.M.1
  • 19
    • 0024413625 scopus 로고
    • Defining a standard intubating position using "angle finder
    • 2917111 10.1093/bja/62.1.6 1:STN:280:DyaL1M7jsVKhtQ%3D%3D
    • Horton WA, Fahy L, Charters P. Defining a standard intubating position using "angle finder". Br J Anaesth. 1989;62:6-12.
    • (1989) Br J Anaesth , vol.62 , pp. 6-12
    • Horton, W.A.1    Fahy, L.2    Charters, P.3
  • 20
    • 58849084108 scopus 로고    scopus 로고
    • Study design, precision, and validity in observational studies
    • 19284267 10.1089/jpm.2008.9690
    • Carlson MD, Morrison RS. Study design, precision, and validity in observational studies. J Palliat Med. 2009;12:77-82.
    • (2009) J Palliat Med , vol.12 , pp. 77-82
    • Carlson, M.D.1    Morrison, R.S.2
  • 21
    • 54249157409 scopus 로고    scopus 로고
    • Practical issues in calculating the sample size for prevalence studies
    • Naing L, Winn T, Rusli BN. Practical issues in calculating the sample size for prevalence studies. Arch Orofac Sci. 2006;1:9-14.
    • (2006) Arch Orofac Sci , vol.1 , pp. 9-14
    • Naing, L.1    Winn, T.2    Rusli, B.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.