메뉴 건너뛰기




Volumn 57, Issue 2, 2013, Pages 201-206

Improvement in clinical evaluation of PET/CT images with high resolution algorithms

Author keywords

Algorithms; Evaluation studies as topic; Positron emission tomography; Tomography; X ray computed

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 84882323227     PISSN: 18244785     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 67650088547 scopus 로고    scopus 로고
    • Qualification of PET scanners for use in multicenter cancer clinical trials: The american college of radiology imaging network experience
    • Scheuermann JS, Saffer JR, Karp JS, Levering AM, Siegel BA. Qualification of PET scanners for use in multicenter cancer clinical trials: the American College of Radiology imaging network experience. J Nucl Med 2009;50:1187-93.
    • (2009) J Nucl Med , vol.50 , pp. 1187-1193
    • Scheuermann, J.S.1    Saffer, J.R.2    Karp, J.S.3    Levering, A.M.4    Siegel, B.A.5
  • 2
    • 84891974206 scopus 로고    scopus 로고
    • Basics of PET imaging: Physics, chemistry, and regulations
    • doi 10.1007/978-1-4419-0805-6-6
    • Saha GB. Basics of PET imaging: physics, chemistry, and regulations, DOI 10.1007/978-1-4419-0805-6-6, Springer Science + Business Media LLC2010.
    • Springer Science + Business Media LLC2010
    • Saha, G.B.1
  • 5
    • 33746191812 scopus 로고    scopus 로고
    • Fully 3-D PET reconstruction with system matrix derived from point source measurements
    • Panin VY, Kehren F, Michel C. Fully 3-D PET reconstruction with system matrix derived from point source measurements. IEEE Trans Med Imaging 2006;25:907-21.
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 907-921
    • Panin, V.Y.1    Kehren, F.2    Michel, C.3
  • 7
    • 76849100926 scopus 로고    scopus 로고
    • Noise and signal properties in PSF-based fully 3D PET image reconstruction: An experimental evaluation
    • Tong S, Alessio AM, Kinahan PE. Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation. Phys Med Biol 2010;55:1453-73.
    • (2010) Phys Med Biol , vol.55 , pp. 1453-1473
    • Tong, S.1    Alessio, A.M.2    Kinahan, P.E.3
  • 8
    • 33847159680 scopus 로고    scopus 로고
    • Quantification of FDG PET studies using standard uptake values in multi center trials. Effects of image reconstruction, resolution and ROI definition parameters
    • Westerterp M, Pruim J, Oyen W, Hoekstra O, Paans A, Visser E et al. Quantification of FDG PET studies using standard uptake values in multi center trials. Effects of image reconstruction, resolution and ROI definition parameters. Eur. J. Nucl. Med. Mol. Imaging 2007;34:392-404.
    • (2007) Eur. J. Nucl. Med. Mol. Imaging , vol.34 , pp. 392-404
    • Westerterp, M.1    Pruim, J.2    Oyen, W.3    Hoekstra, O.4    Paans, A.5    Visser, E.6
  • 9
    • 84856213771 scopus 로고    scopus 로고
    • Impact of 18F-FDG PET imaging parameters on automatic tumour delineation: Need for improved tumour delineation methodology
    • Cheebsumon, Patsuree;Yaqub, Maqsood, Velden. Floris H.P, Hoekstra, Otto S. Lammertsma, Adriaan A., Boellaard, Ronald. Impact of 18F-FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology. Eur J Nucl Med Mol Imaging 2011;38:2136-44.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , pp. 2136-2144
    • Cheebsumon, P.1    Yaqub, M.V.2    Floris, H.P.3    Hoekstra, O.S.4    Lammertsma, A.A.5    Boellaard, R.6
  • 10
    • 6944256515 scopus 로고    scopus 로고
    • Understanding the standardized uptake value, its methods and implication for usage
    • Joseph A, Thie. Understanding the standardized uptake value, its methods and implication for usage. J Nucl Med 2004;45:1431-4.
    • (2004) J Nucl Med , vol.45 , pp. 1431-1434
    • Joseph, A.T.1
  • 11
    • 48749115711 scopus 로고    scopus 로고
    • Variability of lesion detectability and standardize uptake value according to the acquisition procedure and reconstruction among five PET scanners
    • Takashashi Y, Oriuchi N, Otake H, Endo K, Murase K. Variability of lesion detectability and standardize uptake value according to the acquisition procedure and reconstruction among five PET scanners. Ann Nucl Med 2008;22:543-8.
    • (2008) Ann Nucl Med , vol.22 , pp. 543-548
    • Takashashi, Y.1    Oriuchi, N.2    Otake, H.3    Endo, K.4    Murase, K.5
  • 12
    • 34250315240 scopus 로고    scopus 로고
    • Partial volume effect in PET tumor imaging
    • Soret M, Bacharach SL, Buvat I. Partial volume effect in PET tumor imaging. J Nucl Med 2007;48:932-45.
    • (2007) J Nucl Med , vol.48 , pp. 932-945
    • Soret, M.1    Bacharach, S.L.2    Buvat, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.