메뉴 건너뛰기




Volumn 27, Issue 17, 2013, Pages 1977-1982

Improved optimization of the Fourier transform ion cyclotron resonance mass spectrometry phase correction function using a genetic algorithm

Author keywords

[No Author keywords available]

Indexed keywords

CYCLOTRONS; ELECTRON CYCLOTRON RESONANCE; FOURIER SERIES; IMAGE ENHANCEMENT; ITERATIVE METHODS; MASS SPECTROMETERS; MASS SPECTROMETRY; PIXELS; SIGNAL TO NOISE RATIO;

EID: 84882306117     PISSN: 09514198     EISSN: 10970231     Source Type: Journal    
DOI: 10.1002/rcm.6658     Document Type: Article
Times cited : (24)

References (23)
  • 1
    • 0001268221 scopus 로고
    • Fourier transform ion cyclotron resonance spectroscopy
    • M. B. Comisarow, A. G. Marshall,. Fourier transform ion cyclotron resonance spectroscopy. Chem. Phys. Lett. 1974, 25, 282.
    • (1974) Chem. Phys. Lett. , vol.25 , pp. 282
    • Comisarow, M.B.1    Marshall, A.G.2
  • 2
    • 0030461690 scopus 로고    scopus 로고
    • Fourier transform mass spectrometry
    • I. J. Amster,. Fourier transform mass spectrometry. J. Mass Spectrom. 1996, 31, 1325.
    • (1996) J. Mass Spectrom. , vol.31 , pp. 1325
    • Amster, I.J.1
  • 4
    • 0000537072 scopus 로고
    • Comprehensive theory for ion cyclotron resonance power absorption - Application to line shapes for reactive and nonreactive ions
    • M. B. Comisarow,. Comprehensive theory for ion cyclotron resonance power absorption-Application to line shapes for reactive and nonreactive ions. J. Chem. Phys. 1971, 55, 205.
    • (1971) J. Chem. Phys. , vol.55 , pp. 205
    • Comisarow, M.B.1
  • 5
    • 0000399657 scopus 로고
    • Theory for ion cyclotron resonance absorption line shapes
    • A. G. Marshall,. Theory for ion cyclotron resonance absorption line shapes. J. Chem. Phys. 1971, 55, 1343.
    • (1971) J. Chem. Phys. , vol.55 , pp. 1343
    • Marshall, A.G.1
  • 7
    • 79952517625 scopus 로고    scopus 로고
    • Phase correction of Fourier transform ion cyclotron resonance mass spectra using MatLab
    • Y. Qi, C. Thompson, S. Van Orden, P. O'Connor,. Phase correction of Fourier transform ion cyclotron resonance mass spectra using MatLab. J. Am. Soc. Mass. Spectrom. 2011, 22, 138.
    • (2011) J. Am. Soc. Mass. Spectrom. , vol.22 , pp. 138
    • Qi, Y.1    Thompson, C.2    Van Orden, S.3    O'Connor, P.4
  • 8
    • 0001268221 scopus 로고
    • Fourier-transform ion-cyclotron resonance spectroscopy
    • M. B. Comisarow, A. G. Marshall,. Fourier-transform ion-cyclotron resonance spectroscopy. Chem. Phys. Lett. 1974, 25, 282.
    • (1974) Chem. Phys. Lett. , vol.25 , pp. 282
    • Comisarow, M.B.1    Marshall, A.G.2
  • 9
    • 0033555329 scopus 로고    scopus 로고
    • Phase correction for collision model analysis and enhanced resolving power of Fourier transform ion cyclotron resonance mass spectra
    • B. A. Vining, R. E. Bossio, A. G. Marshall,. Phase correction for collision model analysis and enhanced resolving power of Fourier transform ion cyclotron resonance mass spectra. Anal. Chem. 1999, 71, 460.
    • (1999) Anal. Chem. , vol.71 , pp. 460
    • Vining, B.A.1    Bossio, R.E.2    Marshall, A.G.3
  • 10
    • 0000851292 scopus 로고
    • Automated phase correction of FT-NMR spectra be means of phase measurement based on dispersion versus absorption relation (DISPA)
    • E. C. Craig, A. G. Marshall,. Automated phase correction of FT-NMR spectra be means of phase measurement based on dispersion versus absorption relation (DISPA). J. Mag. Reson. 1988, 76, 458.
    • (1988) J. Mag. Reson. , vol.76 , pp. 458
    • Craig, E.C.1    Marshall, A.G.2
  • 11
    • 4744352678 scopus 로고    scopus 로고
    • Broadband phase correction of FT-ICR mass spectra via simultaneous excitation and detection
    • S. C. Beu, G. T. Blakney, J. P. Quinn, C. L. Hendrickson, A. G. Marshall,. Broadband phase correction of FT-ICR mass spectra via simultaneous excitation and detection. Anal. Chem. 2004, 76, 5756.
    • (2004) Anal. Chem. , vol.76 , pp. 5756
    • Beu, S.C.1    Blakney, G.T.2    Quinn, J.P.3    Hendrickson, C.L.4    Marshall, A.G.5
  • 12
    • 78049516195 scopus 로고    scopus 로고
    • Automated broadband phase correction of Fourier transform ion cyclotron resonance mass spectra
    • F. Xian, C. L. Hendrickson, G. T. Blakney, S. C. Beu, A. G. Marshall,. Automated broadband phase correction of Fourier transform ion cyclotron resonance mass spectra. Anal. Chem. 2010, 82, 8807.
    • (2010) Anal. Chem. , vol.82 , pp. 8807
    • Xian, F.1    Hendrickson, C.L.2    Blakney, G.T.3    Beu, S.C.4    Marshall, A.G.5
  • 13
    • 84865484414 scopus 로고    scopus 로고
    • Baseline correction of absorption-mode Fourier transform ion cyclotron resonance mass spectra
    • F. Xian, Y. E. Corilo, C. L. Hendrickson, A. G. Marshall,. Baseline correction of absorption-mode Fourier transform ion cyclotron resonance mass spectra. Int. J. Mass. Spectrom. 2012, 325-327, 67.
    • (2012) Int. J. Mass. Spectrom. , vol.325-327 , pp. 67
    • Xian, F.1    Corilo, Y.E.2    Hendrickson, C.L.3    Marshall, A.G.4
  • 16
    • 84876255896 scopus 로고    scopus 로고
    • Autophaser: An algorithm for automated generation of absorption mode spectra for FT-ICR MS
    • D. P. A. Kilgour, R. Wills, Y. Qi, P. B. O'Connor,. Autophaser: An algorithm for automated generation of absorption mode spectra for FT-ICR MS. Anal. Chem. 2013, 85, 3903.
    • (2013) Anal. Chem. , vol.85 , pp. 3903
    • Kilgour, D.P.A.1    Wills, R.2    Qi, Y.3    O'Connor, P.B.4
  • 17
    • 0001878067 scopus 로고
    • Image charge-induced ion cyclotron orbital frequency shift for orthorhombic and cylindrical FT-ICR ion traps
    • X. Xiang, P. B. Grosshans, A. G. Marshall,. Image charge-induced ion cyclotron orbital frequency shift for orthorhombic and cylindrical FT-ICR ion traps. Int. J. Mass Spectrom. Ion Processes 1993, 125, 33.
    • (1993) Int. J. Mass Spectrom. Ion Processes , vol.125 , pp. 33
    • Xiang, X.1    Grosshans, P.B.2    Marshall, A.G.3
  • 18
    • 74249089408 scopus 로고    scopus 로고
    • Comparison of particle-in-cell simulations with experimentally observed frequency shifts between ions of the same mass-to-charge in fourier transform ion cyclotron resonance mass spectrometry
    • F. E. Leach, A. Kharchenko, R. M. Heeren, E. Nikolaev, I. J. Amster,. Comparison of particle-in-cell simulations with experimentally observed frequency shifts between ions of the same mass-to-charge in fourier transform ion cyclotron resonance mass spectrometry. J. Am. Soc. Mass. Spectrom. 2010, 21, 203.
    • (2010) J. Am. Soc. Mass. Spectrom. , vol.21 , pp. 203
    • Leach, F.E.1    Kharchenko, A.2    Heeren, R.M.3    Nikolaev, E.4    Amster, I.J.5
  • 19
    • 0002629429 scopus 로고
    • An overview of evolutionary algorithms in multiobjective optimization
    • C. M. Fonseca, P. J. Fleming,. An overview of evolutionary algorithms in multiobjective optimization. Evolutionary Computation 1995, 3, 1.
    • (1995) Evolutionary Computation , vol.3 , pp. 1
    • Fonseca, C.M.1    Fleming, P.J.2
  • 20
    • 0026290148 scopus 로고
    • Genetic algorithms: An evolution from Monte Carlo Methods for strongly non-linear geophysical optimization problems
    • K. Gallagher, M. Sambridge, G. Drijkoningen,. Genetic algorithms: An evolution from Monte Carlo Methods for strongly non-linear geophysical optimization problems. Geophys. Res. Lett. 1991, 18, 2177.
    • (1991) Geophys. Res. Lett. , vol.18 , pp. 2177
    • Gallagher, K.1    Sambridge, M.2    Drijkoningen, G.3
  • 21
    • 0034403006 scopus 로고    scopus 로고
    • Evolutionary Monte Carlo: Application to Cp model sampling and change point problem
    • L. Faming, H. W. Wing,. Evolutionary Monte Carlo: Application to Cp model sampling and change point problem. Statistica Sinica 2000, 10, 317.
    • (2000) Statistica Sinica , vol.10 , pp. 317
    • Faming, L.1    Wing, H.W.2
  • 23
    • 85159253352 scopus 로고    scopus 로고
    • Available: www.warwick.ac.uk/autophaser.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.