메뉴 건너뛰기




Volumn , Issue , 2013, Pages 1078-1082

A thermal energy balance model for hypotension prevention in hemodialysis

Author keywords

extracorporeal circulation; hemodialysis; hypotension; temperature measurement; thermal energy exchange

Indexed keywords

ENERGY EXCHANGES; EXTRACORPOREAL CIRCULATION; EXTRACORPOREAL SYSTEMS; HEMODIALYSIS; HYPOTENSION; PERIPHERAL BODY TEMPERATURES; SOLUTION TEMPERATURE; TWO CONTROL PARAMETERS;

EID: 84882282964     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/I2MTC.2013.6555580     Document Type: Conference Paper
Times cited : (3)

References (25)
  • 1
    • 53549088675 scopus 로고    scopus 로고
    • Management of hypotension in dialysis patients: Role of dialysate temperature control
    • F.M. van der Sande, "Management of Hypotension in Dialysis Patients: Role of Dialysate Temperature Control", Saudi Journal of Kidney Diseases and Transplantation, Vol. 12, Issue 3, pp. 328-386, 2001.
    • (2001) Saudi Journal of Kidney Diseases and Transplantation , vol.12 , Issue.3 , pp. 328-386
    • Van Der Sande, F.M.1
  • 3
    • 0026078098 scopus 로고
    • Dialysis hypotension: A hemodynamic analysis
    • JT Daugirdas, "Dialysis hypotension: a hemodynamic analysis", Kidney Int, Vol.39, pp. 233-246, 1991.
    • (1991) Kidney Int , vol.39 , pp. 233-246
    • Daugirdas, J.T.1
  • 5
    • 78651422400 scopus 로고    scopus 로고
    • Prevention of hemodialysis-induced hypotension by increasing the venous return
    • Y. Hitomi et al., "Prevention of hemodialysis-induced hypotension by increasing the venous return", World Automation Congress (WAC), pp. 1-6, 2010.
    • (2010) World Automation Congress (WAC) , pp. 1-6
    • Hitomi, Y.1
  • 6
    • 84864606017 scopus 로고    scopus 로고
    • Relation between trends in body temperature and outcome in incident hemodialysis patients
    • L. A. Usvyat et al., "Relation between trends in body temperature and outcome in incident hemodialysis patients", Nephrol Dial Transplant, vol. 27 pp. 3255-3263, 2012.
    • (2012) Nephrol Dial Transplant , vol.27 , pp. 3255-3263
    • Usvyat, L.A.1
  • 7
    • 33745615802 scopus 로고    scopus 로고
    • A systematic review of the clinical effects of reducing dialysate fluid temperature
    • DOI 10.1093/ndt/gfl126
    • N. M. Selby, C. W. McIntyre, "A systematic review of the clinical effects of reducing dialysate fluid temperature", Nephrol Dial Transplant, vol. 21, pp. 1883-1898, 2006. (Pubitemid 43985717)
    • (2006) Nephrology Dialysis Transplantation , vol.21 , Issue.7 , pp. 1883-1898
    • Selby, N.M.1    McIntyre, C.W.2
  • 8
    • 0034876568 scopus 로고    scopus 로고
    • Thermal effects and blood pressure response during postdilution hemodiafiltration and hemodialysis: The effect of amount of replacement fluid and dialysate temperature
    • F. M. Van der Sande, J. P. Kooman, C. J. Konings, K. M. L. Leunissen, "Thermal Effects and Blood Pressure Response during Postdilution Hemodiafiltration and Hemodialysis: The Effect of Amount of Replacement Fluid and Dialysate Temperature", J. Am Soc Nephrol, vol. 12, pp. 1916-1920, 2001. (Pubitemid 32801367)
    • (2001) Journal of the American Society of Nephrology , vol.12 , Issue.9 , pp. 1916-1920
    • Van Der Sande, F.M.1    Kooman, J.P.2    Konings, C.J.3    Leunissen, K.M.L.4
  • 10
    • 0023771274 scopus 로고
    • The effect of cooled dialysate on thermal energy balance in hemodialysis patients
    • R. Provenzano, et al., "The effect of cooled dialysate on thermal energy balance in hemodialysis patients", Trans. Am. Soc. Artif Intern Organs; vol. 34 pp. 515-8, 1988.
    • (1988) Trans. Am. Soc. Artif Intern Organs; , vol.34 , pp. 515-518
    • Provenzano, R.1
  • 14
    • 84859991728 scopus 로고    scopus 로고
    • Heart rate variability during hemodialysis and its relation to hypotension
    • D. Hernando, R. Bailon, P. Laguna, L. Sornmo, "Heart rate variability during hemodialysis and its relation to hypotension", IEEE Computing in Cardiology, pp. 189-192, 2011.
    • (2011) IEEE Computing in Cardiology , pp. 189-192
    • Hernando, D.1    Bailon, R.2    Laguna, P.3    Sornmo, L.4
  • 16
    • 77956755672 scopus 로고    scopus 로고
    • A wireless measurement system for estimation of human exposure to vibration during the use of hand-held percussion machines
    • R. Morello, C. De Capua, A. Meduri, "A Wireless Measurement System for Estimation of Human Exposure to Vibration During the Use of Hand-Held Percussion Machines", IEEE Transactions on Instrumentation and Measurement, Vol. 59; pp. 2513-2521, 2010.
    • (2010) IEEE Transactions on Instrumentation and Measurement , vol.59 , pp. 2513-2521
    • Morello, R.1    De Capua, C.2    Meduri, A.3
  • 17
    • 80052373949 scopus 로고    scopus 로고
    • Uncertainty analysis in hemodynamic variables measurement for reliable diagnosis of pulmonary hypertension with non-invasive techniques
    • 30-31 May, Bari, Italy
    • R. Morello, C. De Capua, M.G. Belvedere, "Uncertainty Analysis in Hemodynamic Variables Measurement for Reliable Diagnosis of Pulmonary Hypertension with Non-invasive Techniques", IEEE 6th International Workshop on Medical Measurement and Applications (MeMeA 2001), pp. 261-266, 30-31 May 2011, Bari, Italy.
    • (2011) IEEE 6th International Workshop on Medical Measurement and Applications (MeMeA 2001) , pp. 261-266
    • Morello, R.1    De Capua, C.2    Belvedere, M.G.3
  • 22
    • 34548011043 scopus 로고    scopus 로고
    • EBPG guideline on haemodynamic instability
    • J, Kooman et al. (EBPG Working Group), "EBPG guideline on haemodynamic instability", Nephrol Dial Transplant J., Vol. 22, Suppl 2, (2007).
    • (2007) Nephrol Dial Transplant J. , vol.22 , Issue.SUPPL. 2
    • Kooman, J.1
  • 23
    • 34548014552 scopus 로고    scopus 로고
    • EBPG guideline on dialysis strategies
    • J. Tattersall, et al. (EBPG Working Group), "EBPG guideline on dialysis strategies", Nephrol Dial Transplant J., Vol.22, Suppl 2, 2007.
    • (2007) Nephrol Dial Transplant J. , vol.22 , Issue.SUPPL. 2
    • Tattersall, J.1
  • 24
    • 84888360034 scopus 로고
    • Analysis of tissue and arterial blood temperatures in the resting human forearm
    • H. H. Pennes, "Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm", J Appl Physiol August 1, 1948 1:(2) 93-122.
    • (1948) J Appl Physiol August 1 , vol.1 , Issue.2 , pp. 93-122
    • Pennes, H.H.1
  • 25
    • 0031854948 scopus 로고    scopus 로고
    • Pennes' 1948 paper revisited
    • E. H. Wissler, "Pennes' 1948 paper revisited", J. Appl Physiol July 1, vol. 85, no. 1, pp. 35-41, 1998. (Pubitemid 28334903)
    • (1998) Journal of Applied Physiology , vol.85 , Issue.1 , pp. 35-41
    • Wissler, E.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.