Control of ventricular unloading using an electrocardiogram-synchronized Thoratec paracorporeal ventricular assist device

Author keywords

ECG; electrocardiogram; left ventricle; left ventricular assist device; LV; LVAD; VAD; ventricular assist device

Indexed keywords

ANIMAL EXPERIMENT; AORTA PRESSURE; AORTA VALVE; ARTICLE; CEREBROVASCULAR ACCIDENT; ELECTROCARDIOGRAM; FEMALE; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE PRESSURE; HEART LEFT VENTRICLE VOLUME; HEMODYNAMICS; LEFT VENTRICULAR ASSIST DEVICE; NONHUMAN; PRESSURE CHAMBER; PRIORITY JOURNAL; R WAVE; SHEEP;

EID: 84881617148     PISSN: 00225223     EISSN: 1097685X     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2012.12.048     Document Type: Article
Times cited : (29)

References (25)
  • 1
    • 0035783884 scopus 로고    scopus 로고
    • Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
    • O. Frazier, E.A. Rose, M.C. Oz, W. Dembitsky, P. McCarthy, and B. Radovancevic Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation J Thorac Cardiovasc Surg 122 2001 1186 1195
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 1186-1195
    • Frazier, O.1    Rose, E.A.2    Oz, M.C.3    Dembitsky, W.4    McCarthy, P.5    Radovancevic, B.6
  • 2
    • 0029113695 scopus 로고
    • Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system
    • O.H. Frazier, E.A. Rose, P. McCarthy, N.A. Burton, A. Tector, and H. Levin Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system Ann Surg 222 1995 327 338
    • (1995) Ann Surg , vol.222 , pp. 327-338
    • Frazier, O.H.1    Rose, E.A.2    McCarthy, P.3    Burton, N.A.4    Tector, A.5    Levin, H.6
  • 3
    • 0037129864 scopus 로고    scopus 로고
    • Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system
    • O.H. Frazier, T.J. Myers, I.D. Gregoric, T. Khan, R. Delgado, and M. Croitoru Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system Circulation 105 2002 2855 2860
    • (2002) Circulation , vol.105 , pp. 2855-2860
    • Frazier, O.H.1    Myers, T.J.2    Gregoric, I.D.3    Khan, T.4    Delgado, R.5    Croitoru, M.6
  • 5
    • 1642564239 scopus 로고    scopus 로고
    • Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support
    • S. Klotz, M.C. Deng, J. Stypmann, J. Roetker, M.J. Wilhelm, and D. Hammel Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support Ann Thorac Surg 77 2004 143 150
    • (2004) Ann Thorac Surg , vol.77 , pp. 143-150
    • Klotz, S.1    Deng, M.C.2    Stypmann, J.3    Roetker, J.4    Wilhelm, M.J.5    Hammel, D.6
  • 6
    • 77958022676 scopus 로고    scopus 로고
    • Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model
    • G.V. Letsou, T.D. Pate, J.R. Gohean, M. Kurusz, R.G. Longoria, and L. Kaiser Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model J Thorac Cardiovasc Surg 140 2010 1181 1188
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 1181-1188
    • Letsou, G.V.1    Pate, T.D.2    Gohean, J.R.3    Kurusz, M.4    Longoria, R.G.5    Kaiser, L.6
  • 7
    • 83555170951 scopus 로고    scopus 로고
    • Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling
    • T.S. Kato, A. Chokshi, P. Singh, T. Khawaja, F. Cheema, and H. Akashi Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling Circ Heart Fail 4 2011 546 553
    • (2011) Circ Heart Fail , vol.4 , pp. 546-553
    • Kato, T.S.1    Chokshi, A.2    Singh, P.3    Khawaja, T.4    Cheema, F.5    Akashi, H.6
  • 8
    • 58249093243 scopus 로고    scopus 로고
    • Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
    • S. Crow, R. John, A. Boyle, S. Shumway, K. Liao, and M. Colvin-Adams Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices J Thorac Cardiovasc Surg 137 2009 208 215
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 208-215
    • Crow, S.1    John, R.2    Boyle, A.3    Shumway, S.4    Liao, K.5    Colvin-Adams, M.6
  • 9
    • 18744368076 scopus 로고    scopus 로고
    • Time course of reverse remodeling of the left ventricle during support with a left ventricular assist device
    • J.D. Madigan, A. Barbone, A.F. Choudhri, D.L.S. Morales, B. Cai, and M.C. Oz Time course of reverse remodeling of the left ventricle during support with a left ventricular assist device J Thorac Cardiovasc Surg 121 2001 902 908
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 902-908
    • Madigan, J.D.1    Barbone, A.2    Choudhri, A.F.3    Morales, D.L.S.4    Cai, B.5    Oz, M.C.6
  • 10
    • 0036131260 scopus 로고    scopus 로고
    • Partial loading of the left ventricle during mechanical assist device support is associated with improved myocardial function, blood flow and metabolism and increased exercise capacity
    • S. Maybaum, S. Epstein, A. Beniaminovitz, M.D. Tullio, M. Oz, and S.R. Bergmann Partial loading of the left ventricle during mechanical assist device support is associated with improved myocardial function, blood flow and metabolism and increased exercise capacity J Heart Lung Transplant 21 2002 446 454
    • (2002) J Heart Lung Transplant , vol.21 , pp. 446-454
    • Maybaum, S.1    Epstein, S.2    Beniaminovitz, A.3    Tullio, M.D.4    Oz, M.5    Bergmann, S.R.6
  • 11
    • 33746698969 scopus 로고    scopus 로고
    • Left ventricular assist device weaning: Hemodynamic response and relationship to stroke volume and rate reduction protocols
    • M.S. Slaughter, M.A. Sobieski, S.C. Koenig, P.S. Pappas, A.J. Tatooles, and M.A. Silver Left ventricular assist device weaning: Hemodynamic response and relationship to stroke volume and rate reduction protocols ASAIO J 52 2006 228 233
    • (2006) ASAIO J , vol.52 , pp. 228-233
    • Slaughter, M.S.1    Sobieski, M.A.2    Koenig, S.C.3    Pappas, P.S.4    Tatooles, A.J.5    Silver, M.A.6
  • 13
    • 0036253016 scopus 로고    scopus 로고
    • Assessment of synchrony relationships between the native left ventricle and the HeartMate left ventricular assist device
    • S. Maybaum, M. Williams, A. Barbone, H. Levin, M. Oz, and D. Mancini Assessment of synchrony relationships between the native left ventricle and the HeartMate left ventricular assist device J Heart Lung Transplant 21 2002 509 515
    • (2002) J Heart Lung Transplant , vol.21 , pp. 509-515
    • Maybaum, S.1    Williams, M.2    Barbone, A.3    Levin, H.4    Oz, M.5    Mancini, D.6
  • 16
    • 0023840653 scopus 로고
    • Effect of drive mode of left ventricular assist device on the left ventricular mechanics
    • T. Nakamura, K. Hayashi, J. Seki, T. Nakatani, H. Noda, and H. Takano Effect of drive mode of left ventricular assist device on the left ventricular mechanics Artif Organs 12 1988 56 66
    • (1988) Artif Organs , vol.12 , pp. 56-66
    • Nakamura, T.1    Hayashi, K.2    Seki, J.3    Nakatani, T.4    Noda, H.5    Takano, H.6
  • 17
    • 0021892137 scopus 로고
    • A real-time QRS detection algorithm
    • J. Pan, and W.J. Tompkins A real-time QRS detection algorithm IEEE Trans Biomed Eng 32 1985 230 236
    • (1985) IEEE Trans Biomed Eng , vol.32 , pp. 230-236
    • Pan, J.1    Tompkins, W.J.2
  • 18
    • 26444584329 scopus 로고    scopus 로고
    • Nonlinear conductance-volume relationship for murine conductance catheter measurement system
    • C.L. Wei, J.W. Valvano, M.D. Feldman, and J.A. Pearce Nonlinear conductance-volume relationship for murine conductance catheter measurement system IEEE Trans Biomed Eng 52 2005 1654 1661
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1654-1661
    • Wei, C.L.1    Valvano, J.W.2    Feldman, M.D.3    Pearce, J.A.4
  • 19
    • 0026012982 scopus 로고
    • Relation between left ventricular cavity pressure and volume and systolic fiber stress and strain in the wall
    • T. Arts, P.H.M. Bovendeerd, F.W. Prinzen, and R.S. Reneman Relation between left ventricular cavity pressure and volume and systolic fiber stress and strain in the wall Biophys J 59 1991 93 102
    • (1991) Biophys J , vol.59 , pp. 93-102
    • Arts, T.1    Bovendeerd, P.H.M.2    Prinzen, F.W.3    Reneman, R.S.4
  • 22
    • 0027514234 scopus 로고
    • Performance optimization of left ventricular assistance. A computer model study
    • K.L. Platt, T.W. Moore, O. Barnea, S.E. Dubin, and D. Jaron Performance optimization of left ventricular assistance. A computer model study ASAIO J 39 1993 29 38
    • (1993) ASAIO J , vol.39 , pp. 29-38
    • Platt, K.L.1    Moore, T.W.2    Barnea, O.3    Dubin, S.E.4    Jaron, D.5
  • 24
    • 0032033053 scopus 로고    scopus 로고
    • Inflow valve regurgitation during left ventricular assist device support may interfere with reverse ventricular remodeling
    • N. Moazami, M. Argenziano, T. Kohomoto, S. Yazdani, E.A. Rose, and D. Burkhoff Inflow valve regurgitation during left ventricular assist device support may interfere with reverse ventricular remodeling Ann Thorac Surg 65 1998 628 631
    • (1998) Ann Thorac Surg , vol.65 , pp. 628-631
    • Moazami, N.1    Argenziano, M.2    Kohomoto, T.3    Yazdani, S.4    Rose, E.A.5    Burkhoff, D.6
  • 25
    • 33645743807 scopus 로고    scopus 로고
    • Modeling ventricular function during cardiac assist: Does time-varying elastance work?
    • S. Vandenberghe, P. Segers, P. Steendijk, B. Meyns, R.A.E. Dion, and J.F. Antaki Modeling ventricular function during cardiac assist: does time-varying elastance work? ASAIO J 52 2006 4 8
    • (2006) ASAIO J , vol.52 , pp. 4-8
    • Vandenberghe, S.1    Segers, P.2    Steendijk, P.3    Meyns, B.4    Dion, R.A.E.5    Antaki, J.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.