메뉴 건너뛰기




Volumn 43, Issue 3, 2013, Pages 79-89

Performance of a novel NMR apparatus with a solenoidal tape-shaped antenna and a split-type superconducting magnet

Author keywords

B0 homogeneity; B1 homogeneity; Cryogenic probe; Magnetic field stability; Signal to noise ratio; Solenoid antenna; Split magnet

Indexed keywords


EID: 84881594638     PISSN: 15525031     EISSN: 1552504X     Source Type: Journal    
DOI: 10.1002/cmr.b.21236     Document Type: Article
Times cited : (1)

References (12)
  • 4
    • 45149096303 scopus 로고    scopus 로고
    • A new configuration of high-resolution NMR spectrometer with superconducting split-magnet
    • Okada M, Kitaguchi H. 2008. A new configuration of high-resolution NMR spectrometer with superconducting split-magnet. IEEE Trans Appl Supercond 18:878-881.
    • (2008) IEEE Trans Appl Supercond , vol.18 , pp. 878-881
    • Okada, M.1    Kitaguchi, H.2
  • 5
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the nuclear magnetic resonance experiment
    • Hoult DI, Richards RE. 1976. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson 24:71-85.
    • (1976) J Magn Reson , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richards, R.E.2
  • 6
    • 0035630560 scopus 로고    scopus 로고
    • Solenoidal microcoil design. II. Optimizing winding parameters for maximum signal-to-noise performance
    • Minard KR, Wind RA. 2001. Solenoidal microcoil design. II. Optimizing winding parameters for maximum signal-to-noise performance. Concept Magn Reson 13:190-210.
    • (2001) Concept Magn Reson , vol.13 , pp. 190-210
    • Minard, K.R.1    Wind, R.A.2
  • 7
    • 77952999854 scopus 로고    scopus 로고
    • Designing a solenoid coil of high sensitivity for a cryogenic probe of a novel split magnet
    • Park M, Kawasaki K, Okada M, Kitaguchi H. 2010. Designing a solenoid coil of high sensitivity for a cryogenic probe of a novel split magnet. Concept Magn Reson B 37:92-101.
    • (2010) Concept Magn Reson B , vol.37 , pp. 92-101
    • Park, M.1    Kawasaki, K.2    Okada, M.3    Kitaguchi, H.4
  • 9
    • 42149171744 scopus 로고    scopus 로고
    • Development of cryogenic cooling system using a double GM cryo-cooler for NMR spectrometer
    • Tanaka H, Fukuda Y, Okada M, Saho N, Saitoh K. Kitaguchi H. 2008. Development of cryogenic cooling system using a double GM cryo-cooler for NMR spectrometer. J Phys: Conf Ser 97:012232.
    • (2008) J Phys: Conf Ser , vol.97 , pp. 012232
    • Tanaka, H.1    Fukuda, Y.2    Okada, M.3    Saho, N.4    Saitoh, K.5    Kitaguchi, H.6
  • 11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.