메뉴 건너뛰기




Volumn , Issue , 2010, Pages 471-477

Exploring techniques for monitoring electric power consumption in households

Author keywords

Energy awareness; Fingerprinting; Load monitoring; Pattern recognition; Ubiquitous computing

Indexed keywords

CONTEXT AWARE SERVICES; CURRENT HARMONICS; ELECTRIC POWER CONSUMPTION; ELECTRICAL APPLIANCES; ENERGY AWARENESS; FINGERPRINTING; FUTURE APPLICATIONS; LOAD MONITORING;

EID: 84881576637     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (20)
  • 3
    • 0026970695 scopus 로고
    • Nonintrusive appliance load monitoring
    • Dec., doi: 10.1109/5.192069
    • G.W Hart, "Nonintrusive Appliance Load Monitoring, " Proceedings of the IEEE, vol. 80, no. 12, Dec. 1992, pp. 1870-1891, doi: 10.1109/5.192069.
    • (1992) Proceedings of the IEEE , vol.80 , Issue.12 , pp. 1870-1891
    • Hart, G.W.1
  • 8
    • 0242369050 scopus 로고    scopus 로고
    • Power signature analysis
    • Mar-Apr., doi: 10.1109/MPAE.2003.1192027
    • C. Laughman et al., "Power Signature Analysis, " Power and Energy Magazine, vol. 1, no. 2, Mar-Apr. 2003, pp. 56-63, doi: 10.1109/MPAE.2003.1192027.
    • (2003) Power and Energy Magazine , vol.1 , Issue.2 , pp. 56-63
    • Laughman, C.1
  • 9
    • 77956123172 scopus 로고    scopus 로고
    • Non-intrusive electric appliances load efficient monitoring system using harmonic pattern recognition- performance test results at real households
    • June, London
    • Y. Nakano et al., "Non-Intrusive Electric Appliances Load Efficient Monitoring System Using Harmonic Pattern Recognition- Performance Test Results at Real Households, " The Fourth International Conference on Energy Efficiency in Domestic Appliances and Lighting (EEDAL), June 2006, London.
    • (2006) The Fourth International Conference on Energy Efficiency in Domestic Appliances and Lighting (EEDAL)
    • Nakano, Y.1
  • 10
    • 27944457627 scopus 로고    scopus 로고
    • Fuzzy logic based pattern recognition technique for nonintrusive load monitoring
    • IEEE Press, Nov., doi: 10.1109/TENCON.2004.1414824
    • S.R. Kamat, "Fuzzy Logic Based Pattern Recognition Technique for Nonintrusive Load Monitoring, " Proc. IEEE Regional 10 Conference (TENCON 2004), IEEE Press, Nov. 2004, vol.3, pp. 528-530, doi: 10.1109/TENCON.2004. 1414824.
    • (2004) Proc. IEEE Regional 10 Conference (TENCON 2004) , vol.3 , pp. 528-530
    • Kamat, S.R.1
  • 11
    • 70350187399 scopus 로고    scopus 로고
    • Nonintrusive appliance load monitoring based on an optical sensor
    • June, IEEE Press, doi: 10.1109/PTC.2003.1304732
    • M. Baranski and J. Voss, "Nonintrusive Appliance Load Monitoring based on an Optical Sensor, " Proc. IEEE Power Tech Conference 2003 IEEE Bologna, June 2003, IEEE Press, vol. 4, 8 pp., doi: 10.1109/PTC.2003.1304732.
    • (2003) Proc. IEEE Power Tech Conference 2003 IEEE Bologna , vol.4 , pp. 8
    • Baranski, M.1    Voss, J.2
  • 12
    • 74349124143 scopus 로고    scopus 로고
    • Automatic electric load identification in self-configuring microgrids
    • IEEE Press, Sept., doi: 10.1109/AFRCON.2009.5308129
    • F. Kupzog, T. Zia, and A.A. Zaidi, "Automatic Electric Load Identification in Self-Configuring Microgrids, " Proc. AFRICON 2009 (AFRICON 09), IEEE Press, Sept. 2009, pp. 1-5, doi: 10.1109/AFRCON.2009.5308129.
    • (2009) Proc. Africon 2009 (Africon 09) , pp. 1-5
    • Kupzog, F.1    Zia, T.2    Zaidi, A.A.3
  • 13
    • 56749149529 scopus 로고    scopus 로고
    • Nonintrusive appliance load monitoring based on integer programming
    • IEEE Press, Aug., doi: 10.1109/SICE.2008.4655131
    • K. Suzuki, S. Inagaki, T. Suzuki, H. Nakamura, and K. Ito, "Nonintrusive Appliance Load Monitoring based on Integer Programming, " Proc. SICE Annual Conference, IEEE Press, Aug. 2008, pp. 2742 - 2747, doi: 10.1109/SICE.2008.4655131.
    • (2008) Proc. SICE Annual Conference , pp. 2742-2747
    • Suzuki, K.1    Inagaki, S.2    Suzuki, T.3    Nakamura, H.4    Ito, K.5
  • 14
    • 77954496984 scopus 로고    scopus 로고
    • Automatically disaggregating the total electrical load in residential buildings: A profile of the required solution
    • July, ISBN: 978-1-84102-191-1
    • H.S. Matthews, L. Soibelman, M. Berges, and E. Goldman, "Automatically Disaggregating the Total Electrical Load in Residential Buildings: A Profile of the Required Solution, " Proc. Intelligent Computing in Engineering (ICE08), July 2008, pp. 381-389, ISBN: 978-1-84102-191-1.
    • (2008) Proc. Intelligent Computing in Engineering (ICE08) , pp. 381-389
    • Matthews, H.S.1    Soibelman, L.2    Berges, M.3    Goldman, E.4
  • 15
    • 0033747416 scopus 로고    scopus 로고
    • Nonintrusive load disaggregation computer program to estimate the energy consumption of major end uses in residential buildings
    • October
    • M.L. Marceau and R. Zmeureanu, "Nonintrusive Load Disaggregation Computer Program to Estimate the Energy Consumption of Major End Uses in Residential Buildings, " Energy Conversion and Management, vol. 41, October 1999, pp. 1389-1403.
    • (1999) Energy Conversion and Management , vol.41 , pp. 1389-1403
    • Marceau, M.L.1    Zmeureanu, R.2
  • 17
    • 84926662675 scopus 로고
    • Nearest neighbor pattern classification
    • Jan., ISSN : 0018-9448
    • T.M. Cover and P.E. Hart, "Nearest Neighbor Pattern Classification, " IEEE Transactions on Information Theory, vol. 13, no. 1, Jan. 1967, pp. 21-27, ISSN : 0018-9448.
    • (1967) IEEE Transactions on Information Theory , vol.13 , Issue.1 , pp. 21-27
    • Cover, T.M.1    Hart, P.E.2
  • 19
    • 78650024390 scopus 로고    scopus 로고
    • Designing effective feedback of electricity consumption for mobile user interfaces
    • G. Jacucci et al., "Designing Effective Feedback of Electricity Consumption for Mobile User Interfaces", PsychNology Journal, vol. 7, no. 3, 2009, pp. 265-289.
    • (2009) PsychNology Journal , vol.7 , Issue.3 , pp. 265-289
    • Jacucci, G.1
  • 20
    • 84881563834 scopus 로고    scopus 로고
    • TOPAS 1000 power quality analyzer
    • LEM Norma GmbH, A 5505 1 GA 3 E Rev. A
    • LEM Norma GmbH, "TOPAS 1000 Power Quality Analyzer", Operating Instructions, 2003, A 5505 1 GA 3 E Rev. A.
    • (2003) Operating Instructions


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.