메뉴 건너뛰기




Volumn , Issue , 2012, Pages 3671-3674

Sparse angular X-ray cone beam CT image iterative reconstruction using normal-dose scan induced nonlocal prior

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMICAL INFORMATION; CONE BEAM CT IMAGES; CONE-BEAM COMPUTED TOMOGRAPHY; IMAGE RECONSTRUCTION ACCURACIES; IMAGE-GUIDED INTERVENTION; ITERATIVE IMAGE RECONSTRUCTION; ITERATIVE RECONSTRUCTION; RECONSTRUCTED IMAGE;

EID: 84881561434     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2012.6551844     Document Type: Conference Paper
Times cited : (3)

References (13)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • Nov.
    • D.J. Brenner, E.J. Hall, "Computed tomography - An increasing source of radiation exposure," N Engl J Med Nov. vol. 357, no. 22, pp. 2277-2284, 2007.
    • (2007) N Engl J Med , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 80053609557 scopus 로고    scopus 로고
    • Low-dose computed tomography image restoration using previous normal-dose scan
    • Oct.
    • J. Ma, J. Huang, Q. Feng, H. Zhang, H. Lu, Z. Liang, and W. Chen, "Low-dose computed tomography image restoration using previous normal-dose scan," Med. Phys., vol. 38, no. 10, pp. 5714-5731, Oct. 2011.
    • (2011) Med. Phys. , vol.38 , Issue.10 , pp. 5714-5731
    • Ma, J.1    Huang, J.2    Feng, Q.3    Zhang, H.4    Lu, H.5    Liang, Z.6    Chen, W.7
  • 4
    • 67649515373 scopus 로고    scopus 로고
    • Directional view interpolation for compensation of sparse angular sampling in cone-beam CT
    • July
    • M. Bertram, J. Wiegert, D. Schäfer, T. Aach and G. Rose, "Directional View Interpolation for Compensation of Sparse Angular Sampling in Cone-Beam CT," IEEE Transactions On Medical Imaging, vol. 28, no. 7, pp. 1011-1022, July 2009.
    • (2009) IEEE Transactions on Medical Imaging , vol.28 , Issue.7 , pp. 1011-1022
    • Bertram, M.1    Wiegert, J.2    Schäfer, D.3    Aach, T.4    Rose, G.5
  • 5
    • 33745162201 scopus 로고    scopus 로고
    • Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
    • E. Y. Sidky, C.M. Kao and X. Pan, "Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT," Journal of X-Ray Science and Technology, no. 14, pp. 119-139, 2006.
    • (2006) Journal of X-Ray Science and Technology , Issue.14 , pp. 119-139
    • Sidky, E.Y.1    Kao, C.M.2    Pan, X.3
  • 6
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • February
    • G.H. Chen, J. Tang and S. Leng, "Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets," Med. Phys., vol. 35, no. 2, pp. 660-663, February, 2008.
    • (2008) Med. Phys. , vol.35 , Issue.2 , pp. 660-663
    • Chen, G.H.1    Tang, J.2    Leng, S.3
  • 7
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • J. Wang, T. Li, H. Lu and Z. Liang, "Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography," IEEE Trans. Med. Imaging no. 25, pp. 1272-83, 2006.
    • (2006) IEEE Trans. Med. Imaging , Issue.25 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4
  • 8
    • 84864264764 scopus 로고    scopus 로고
    • Variance analysis of x-ray CT sinograms in the presence of electronic noise background
    • J. Ma, Z. Liang, Y. Fan, Y. Liu, J. Huang, W. Chen and H. Lu, "Variance analysis of x-ray CT sinograms in the presence of electronic noise background," Med. Phys., no. 39, pp. 4051-65, 2012.
    • (2012) Med. Phys. , Issue.39 , pp. 4051-4065
    • Ma, J.1    Liang, Z.2    Fan, Y.3    Liu, Y.4    Huang, J.5    Chen, W.6    Lu, H.7
  • 9
    • 84869048874 scopus 로고    scopus 로고
    • Iterative image reconstruction for cerebral perfusion CT using pre-contrast scan induced edge-preserving prior
    • J. Ma, H. Zhang, Y. Gao, J. Huang, Z. Liang, Q. Feng and W. Chen, "Iterative image reconstruction for cerebral perfusion CT using pre-contrast scan induced edge-preserving prior," Phys Med Biol. vol. 57, no. 22, pp. 7519-42, 2012.
    • (2012) Phys Med Biol. , vol.57 , Issue.22 , pp. 7519-7542
    • Ma, J.1    Zhang, H.2    Gao, Y.3    Huang, J.4    Liang, Z.5    Feng, Q.6    Chen, W.7
  • 11
    • 84881571519 scopus 로고    scopus 로고
    • http://www.bme.une.edu/~wsegars/.
  • 12
    • 70350645492 scopus 로고    scopus 로고
    • Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms
    • T. Jie, E. Brian and G. Chen, "Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms," Physics in medicine and biology, vol. 54, no. 19, pp. 5781-5804, 2009.
    • (2009) Physics in Medicine and Biology , vol.54 , Issue.19 , pp. 5781-5804
    • Jie, T.1    Brian, E.2    Chen, G.3
  • 13
    • 41449104123 scopus 로고    scopus 로고
    • A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating
    • C. Badea, E. E Schreibmann and T.T Fox, "A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating," Med. Phys., vol. 35, no. 4, pp. 1170-1179, 2008.
    • (2008) Med. Phys. , vol.35 , Issue.4 , pp. 1170-1179
    • Badea, C.1    Schreibmann, E.E.2    Fox, T.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.