메뉴 건너뛰기




Volumn 51, Issue , 2013, Pages 51-70

Analytical applications of chemiluminescence-detection systems assisted by magnetic microparticles and nanoparticles

Author keywords

Analytical application; Chemiluminescence; Immunoassay; Magnetic microparticle; Magnetic molecularly imprinted polymer; Magnetic nanoparticle; Microparticle; Molecularly imprinted polymer; Nanoparticle; Selectivity

Indexed keywords

CATALYST SELECTIVITY; CHEMILUMINESCENCE; IMMUNOLOGY; NANOPARTICLES;

EID: 84881533131     PISSN: 01659936     EISSN: 18793142     Source Type: Journal    
DOI: 10.1016/j.trac.2013.05.014     Document Type: Review
Times cited : (100)

References (112)
  • 1
    • 79958772098 scopus 로고    scopus 로고
    • Recent research progress on the preparation and application of magnetic nanospheres
    • Tai Y., Wang L., Yan G., Gao J.-m., Yu H., Zhang L. Recent research progress on the preparation and application of magnetic nanospheres. Polym. Int. 2011, 60:976-994.
    • (2011) Polym. Int. , vol.60 , pp. 976-994
    • Tai, Y.1    Wang, L.2    Yan, G.3    Gao, J.-M.4    Yu, H.5    Zhang, L.6
  • 2
    • 34547587742 scopus 로고    scopus 로고
    • Micro- and nano- magnetic particles for applications in biosensing
    • Hsing I.M., Xu Y., Zhao W. Micro- and nano- magnetic particles for applications in biosensing. Electroanalysis 2007, 19:755-768.
    • (2007) Electroanalysis , vol.19 , pp. 755-768
    • Hsing, I.M.1    Xu, Y.2    Zhao, W.3
  • 3
    • 79959779818 scopus 로고    scopus 로고
    • A magnetically active microfluidic device for chemiluminescence bioassays
    • Zheng Y., Zhao S., Liu Y.M. A magnetically active microfluidic device for chemiluminescence bioassays. Analyst 2011, 136:2890-2892.
    • (2011) Analyst , vol.136 , pp. 2890-2892
    • Zheng, Y.1    Zhao, S.2    Liu, Y.M.3
  • 4
    • 70349163665 scopus 로고    scopus 로고
    • Magnetic particle-based chemiluminescence enzyme immunoassay for free thyroxine in human serum
    • Jin H., Lin J.M., Wang X., Xin T.B., Liang S.X., Li Z.J., Hu G.M. Magnetic particle-based chemiluminescence enzyme immunoassay for free thyroxine in human serum. J. Pharm. Biomed. Anal. 2009, 50:891-896.
    • (2009) J. Pharm. Biomed. Anal. , vol.50 , pp. 891-896
    • Jin, H.1    Lin, J.M.2    Wang, X.3    Xin, T.B.4    Liang, S.X.5    Li, Z.J.6    Hu, G.M.7
  • 5
    • 84865740523 scopus 로고    scopus 로고
    • Analytical and environmental applications of nanoparticles as enzyme mimetics, TrAC
    • Xie J., Zhang X., Wang H., Zheng H., Huang Y. Analytical and environmental applications of nanoparticles as enzyme mimetics, TrAC. Trends Anal. Chem. 2012, 39:114-129.
    • (2012) Trends Anal. Chem. , vol.39 , pp. 114-129
    • Xie, J.1    Zhang, X.2    Wang, H.3    Zheng, H.4    Huang, Y.5
  • 6
    • 84868590458 scopus 로고    scopus 로고
    • 4 nanoparticles for selective detection and simultaneous determination of various pesticides
    • 4 nanoparticles for selective detection and simultaneous determination of various pesticides. Anal. Chem. 2012, 84:9492-9497.
    • (2012) Anal. Chem. , vol.84 , pp. 9492-9497
    • Guan, G.1    Yang, L.2    Mei, Q.3    Zhang, K.4    Zhang, Z.5    Han, M.-Y.6
  • 8
    • 70349252288 scopus 로고    scopus 로고
    • A novel captopril chemiluminescence system for determination of copper(II) in human hair and cereal flours
    • Sorouraddin M.H., Iranifam M., Imani-Nabiyyi A. A novel captopril chemiluminescence system for determination of copper(II) in human hair and cereal flours. J. Fluoresc. 2009, 19:575-581.
    • (2009) J. Fluoresc. , vol.19 , pp. 575-581
    • Sorouraddin, M.H.1    Iranifam, M.2    Imani-Nabiyyi, A.3
  • 10
    • 58149202243 scopus 로고    scopus 로고
    • Determination of penicillin V potassium in pharmaceuticals and spiked human urine by chemiluminescence
    • Sorouraddin M.H., Iranifam M., Imani-Nabiyyi A. Determination of penicillin V potassium in pharmaceuticals and spiked human urine by chemiluminescence. Cent. Eur. J. Chem. 2009, 7:143-147.
    • (2009) Cent. Eur. J. Chem. , vol.7 , pp. 143-147
    • Sorouraddin, M.H.1    Iranifam, M.2    Imani-Nabiyyi, A.3
  • 12
    • 84880545549 scopus 로고    scopus 로고
    • Revisiting flow-chemiluminescence techniques: pharmaceutical analysis
    • Iranifam M. Revisiting flow-chemiluminescence techniques: pharmaceutical analysis. Luminescence (Published online) 2012, 10.1002/bio.2441.
    • (2012) Luminescence (Published online)
    • Iranifam, M.1
  • 13
    • 84885853356 scopus 로고    scopus 로고
    • A novel selenium nanoparticles-enhanced chemiluminescence system for determination of dinitrobutylphenol
    • Iranifam M., Fathinia M., Sadeghi Rad T., Hanifehpour Y., Khataee A.R., Joo S.W. A novel selenium nanoparticles-enhanced chemiluminescence system for determination of dinitrobutylphenol. Talanta 2013, 107:263-269.
    • (2013) Talanta , vol.107 , pp. 263-269
    • Iranifam, M.1    Fathinia, M.2    Sadeghi Rad, T.3    Hanifehpour, Y.4    Khataee, A.R.5    Joo, S.W.6
  • 15
    • 65049088059 scopus 로고    scopus 로고
    • Magnetic microbead-based electrochemical immunoassays
    • Kuramitz H. Magnetic microbead-based electrochemical immunoassays. Anal. Bioanal. Chem. 2009, 394:61-69.
    • (2009) Anal. Bioanal. Chem. , vol.394 , pp. 61-69
    • Kuramitz, H.1
  • 16
    • 84872716816 scopus 로고    scopus 로고
    • Nanoparticle-based immunoassays in the biomedical field
    • Tang D., Cui Y., Chen G. Nanoparticle-based immunoassays in the biomedical field. Analyst 2013, 138:981-990.
    • (2013) Analyst , vol.138 , pp. 981-990
    • Tang, D.1    Cui, Y.2    Chen, G.3
  • 18
    • 84967404000 scopus 로고    scopus 로고
    • John Wiley & Sons, Inc., New York
    • Shan G. Introduction 2010, John Wiley & Sons, Inc., New York, (pp. 1-4).
    • (2010) Introduction , pp. 1-4
    • Shan, G.1
  • 19
    • 0000380542 scopus 로고
    • Immunoassay of endogenous plasma insulin in man
    • Yalow R.S., Berson S.A. Immunoassay of endogenous plasma insulin in man. J. Clin. Invest. 1960, 39:1157-1175.
    • (1960) J. Clin. Invest. , vol.39 , pp. 1157-1175
    • Yalow, R.S.1    Berson, S.A.2
  • 21
    • 84870784809 scopus 로고    scopus 로고
    • Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: a review
    • Pei X., Zhang B., Tang J., Liu B., Lai W., Tang D. Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: a review. Anal. Chim. Acta 2013, 758:1-18.
    • (2013) Anal. Chim. Acta , vol.758 , pp. 1-18
    • Pei, X.1    Zhang, B.2    Tang, J.3    Liu, B.4    Lai, W.5    Tang, D.6
  • 22
    • 65349108030 scopus 로고    scopus 로고
    • Gold nanolabels for new enhanced chemiluminescence immunoassay of alpha-fetoprotein based on magnetic beads
    • Bi S., Yan Y.M., Yang X.Y., Zhang S.S. Gold nanolabels for new enhanced chemiluminescence immunoassay of alpha-fetoprotein based on magnetic beads. Chem. Eur. J. 2009, 15:4704-4709.
    • (2009) Chem. Eur. J. , vol.15 , pp. 4704-4709
    • Bi, S.1    Yan, Y.M.2    Yang, X.Y.3    Zhang, S.S.4
  • 23
    • 0034611040 scopus 로고    scopus 로고
    • Chemiluminescence as diagnostic tool. A review
    • Dodeigne C., Thunus L., Lejeune R. Chemiluminescence as diagnostic tool. A review. Talanta 2000, 51:415-439.
    • (2000) Talanta , vol.51 , pp. 415-439
    • Dodeigne, C.1    Thunus, L.2    Lejeune, R.3
  • 24
    • 79955917887 scopus 로고    scopus 로고
    • Luminol-based enhanced chemiluminescence assay for quantification of peroxidase and hydrogen peroxide in aqueous solutions: Effect of reagent pH and ionic strength
    • Bhandari A., Kim W., Hohn K. Luminol-based enhanced chemiluminescence assay for quantification of peroxidase and hydrogen peroxide in aqueous solutions: Effect of reagent pH and ionic strength. J. Environ. Eng. 2010, 136:1147-1152.
    • (2010) J. Environ. Eng. , vol.136 , pp. 1147-1152
    • Bhandari, A.1    Kim, W.2    Hohn, K.3
  • 25
    • 79959297723 scopus 로고    scopus 로고
    • A rapid and sensitive chemiluminescence immunoassay based on magnetic particles for squamous cell carcinoma antigen in human serum
    • Zhang H., Qi S. A rapid and sensitive chemiluminescence immunoassay based on magnetic particles for squamous cell carcinoma antigen in human serum. Clin. Chim. Acta 2011, 412:1572-1577.
    • (2011) Clin. Chim. Acta , vol.412 , pp. 1572-1577
    • Zhang, H.1    Qi, S.2
  • 26
    • 27744594319 scopus 로고    scopus 로고
    • Sequential injection chemiluminescence immunoassay for anionic surfactants using magnetic microbeads immobilized with an antibody
    • Zhang R.Q., Hirakawa K., Seto D., Soh N., Nakano K., Masadome T., Nagata K., Sakamoto K., Imato T. Sequential injection chemiluminescence immunoassay for anionic surfactants using magnetic microbeads immobilized with an antibody. Talanta 2005, 68:231-238.
    • (2005) Talanta , vol.68 , pp. 231-238
    • Zhang, R.Q.1    Hirakawa, K.2    Seto, D.3    Soh, N.4    Nakano, K.5    Masadome, T.6    Nagata, K.7    Sakamoto, K.8    Imato, T.9
  • 28
    • 21244505833 scopus 로고    scopus 로고
    • Development of a micro-plate magnetic chemiluminescence enzyme immunoassay (MMCLEIA) for rapid- and high-throughput analysis of 17 beta-estradiol in water samples
    • Zhao L.X., Lin J.M. Development of a micro-plate magnetic chemiluminescence enzyme immunoassay (MMCLEIA) for rapid- and high-throughput analysis of 17 beta-estradiol in water samples. J. Biotechnol. 2005, 118:177-186.
    • (2005) J. Biotechnol. , vol.118 , pp. 177-186
    • Zhao, L.X.1    Lin, J.M.2
  • 29
    • 84873490367 scopus 로고    scopus 로고
    • Multiplex electrochemiluminescence immunoassay of two tumor markers using multicolor quantum dots as labels and graphene asconductingbridge
    • Guo Z., Hao T., Du S., Chen B., Wang Z., Li X., Wang S. Multiplex electrochemiluminescence immunoassay of two tumor markers using multicolor quantum dots as labels and graphene asconductingbridge. Biosens. Bioelectron. 2013, 44:101-107.
    • (2013) Biosens. Bioelectron. , vol.44 , pp. 101-107
    • Guo, Z.1    Hao, T.2    Du, S.3    Chen, B.4    Wang, Z.5    Li, X.6    Wang, S.7
  • 30
    • 84860338092 scopus 로고    scopus 로고
    • Microchip electrophoresis coupled with on-line magnetic separation and chemiluminescence detection for multiplexed immunoassay
    • Huang Y., Zhao S., Shi M., Liu J., Liang H. Microchip electrophoresis coupled with on-line magnetic separation and chemiluminescence detection for multiplexed immunoassay. Electrophoresis 2012, 33:1198-1204.
    • (2012) Electrophoresis , vol.33 , pp. 1198-1204
    • Huang, Y.1    Zhao, S.2    Shi, M.3    Liu, J.4    Liang, H.5
  • 31
    • 70249140182 scopus 로고    scopus 로고
    • Multi-site analytical evaluation of a chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the Abbott ARCHITECT analyzer
    • Schmid R.W., Lotz J., Schweigert R., Lackner K., Aimo G., Friese J., Rosiere T., Dickson D., Kenney D., Maine G.T. Multi-site analytical evaluation of a chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the Abbott ARCHITECT analyzer. Clin. Biochem. 2009, 42:1543-1548.
    • (2009) Clin. Biochem. , vol.42 , pp. 1543-1548
    • Schmid, R.W.1    Lotz, J.2    Schweigert, R.3    Lackner, K.4    Aimo, G.5    Friese, J.6    Rosiere, T.7    Dickson, D.8    Kenney, D.9    Maine, G.T.10
  • 33
    • 0041973574 scopus 로고    scopus 로고
    • High-throughput liquid chromatography-tandem mass spectrometric analysis of sirolimus in whole blood
    • Wallemacq P.E., Vanbinst R., Asta S.P., Cooper D.P. High-throughput liquid chromatography-tandem mass spectrometric analysis of sirolimus in whole blood. Clin. Chem. Lab. Med. 2003, 41:921-925.
    • (2003) Clin. Chem. Lab. Med. , vol.41 , pp. 921-925
    • Wallemacq, P.E.1    Vanbinst, R.2    Asta, S.P.3    Cooper, D.P.4
  • 34
    • 84878242528 scopus 로고    scopus 로고
    • An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads
    • Tao X., Jiang H., Yu X., Zhu J., Wang X., Wang Z., Niu L., Wu X., Shen J. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads. Drug Test. Anal. 2013, 5:346-352.
    • (2013) Drug Test. Anal. , vol.5 , pp. 346-352
    • Tao, X.1    Jiang, H.2    Yu, X.3    Zhu, J.4    Wang, X.5    Wang, Z.6    Niu, L.7    Wu, X.8    Shen, J.9
  • 36
    • 84862783147 scopus 로고    scopus 로고
    • Chemiluminescence enzyme immunoassay using magnetic nanoparticles for detection of neuron specific enolase in human serum
    • Fu X., Meng M., Zhang Y., Yin Y., Zhang X., Xi R. Chemiluminescence enzyme immunoassay using magnetic nanoparticles for detection of neuron specific enolase in human serum. Anal. Chim. Acta 2012, 722:114-118.
    • (2012) Anal. Chim. Acta , vol.722 , pp. 114-118
    • Fu, X.1    Meng, M.2    Zhang, Y.3    Yin, Y.4    Zhang, X.5    Xi, R.6
  • 37
    • 33847618361 scopus 로고    scopus 로고
    • Development of a sensitive micro-magnetic chemiluminescence enzyme immunoassay for the determination of carcinoembryonic antigen
    • Dungchai W., Siangproh W., Lin J.M., Chailapakul O., Lin S., Ying X.T. Development of a sensitive micro-magnetic chemiluminescence enzyme immunoassay for the determination of carcinoembryonic antigen. Anal. Bioanal. Chem. 2007, 387:1965-1971.
    • (2007) Anal. Bioanal. Chem. , vol.387 , pp. 1965-1971
    • Dungchai, W.1    Siangproh, W.2    Lin, J.M.3    Chailapakul, O.4    Lin, S.5    Ying, X.T.6
  • 38
    • 34548018281 scopus 로고    scopus 로고
    • Evaluation of carbohydrate antigen 50 in human serum using magnetic particle-based chemiluminescence enzyme immunoassay
    • Wang X., Lin J.M., Ying X.T. Evaluation of carbohydrate antigen 50 in human serum using magnetic particle-based chemiluminescence enzyme immunoassay. Anal. Chim. Acta 2007, 598:261-267.
    • (2007) Anal. Chim. Acta , vol.598 , pp. 261-267
    • Wang, X.1    Lin, J.M.2    Ying, X.T.3
  • 39
    • 44449172893 scopus 로고    scopus 로고
    • Development of high-performance magnetic chemiluminescence enzyme immunoassay for alpha-fetoprotein (AFP) in human serum
    • Wang X., Zhang Q.Y., Li Z.J., Ying X.T., Lin J.M. Development of high-performance magnetic chemiluminescence enzyme immunoassay for alpha-fetoprotein (AFP) in human serum. Clin. Chim. Acta 2008, 393:90-94.
    • (2008) Clin. Chim. Acta , vol.393 , pp. 90-94
    • Wang, X.1    Zhang, Q.Y.2    Li, Z.J.3    Ying, X.T.4    Lin, J.M.5
  • 40
    • 79959297723 scopus 로고    scopus 로고
    • A rapid and sensitive chemiluminescence immunoassay based on magnetic particles for squamous cell carcinoma antigen in human serum
    • Zhang H., Qi S. A rapid and sensitive chemiluminescence immunoassay based on magnetic particles for squamous cell carcinoma antigen in human serum. Clin. Chim. Acta 2010, 412:1572-1577.
    • (2010) Clin. Chim. Acta , vol.412 , pp. 1572-1577
    • Zhang, H.1    Qi, S.2
  • 41
    • 84890555798 scopus 로고    scopus 로고
    • Development of a rapid and high performance chemiluminescence immunoassay based on magnetic particles for protein S100B in human serum
    • (Published online)
    • H. Zhang, S. Qi, J. Rao, Q. Li, L. Yin, Y. Lu, Development of a rapid and high performance chemiluminescence immunoassay based on magnetic particles for protein S100B in human serum, Luminescence, (Published online) (2013), http://dx.doi.org/10.1002/bio.2461.
    • (2013) Luminescence
    • Zhang, H.1    Qi, S.2    Rao, J.3    Li, Q.4    Yin, L.5    Lu, Y.6
  • 42
    • 77953325651 scopus 로고    scopus 로고
    • Micro-plate magnetic chemiluminescence immunoassay and its applications in carcinoembryonic antigen analysis
    • Li Z., Zhang Q., Zhao L., Li Z., Hu G., Lin J., Wang S. Micro-plate magnetic chemiluminescence immunoassay and its applications in carcinoembryonic antigen analysis. Sci. China Chem. 2010, 53:812-819.
    • (2010) Sci. China Chem. , vol.53 , pp. 812-819
    • Li, Z.1    Zhang, Q.2    Zhao, L.3    Li, Z.4    Hu, G.5    Lin, J.6    Wang, S.7
  • 43
    • 69249229518 scopus 로고    scopus 로고
    • Development of a rapid and sensitive magnetic chemiluminescent enzyme immunoassay for detection of luteinizing hormone in human serum
    • Xiao Q., Li H.F., Hu G.M., Wang H.R., Li Z.J., Lin J.M. Development of a rapid and sensitive magnetic chemiluminescent enzyme immunoassay for detection of luteinizing hormone in human serum. Clin. Biochem. 2009, 42:1461-1467.
    • (2009) Clin. Biochem. , vol.42 , pp. 1461-1467
    • Xiao, Q.1    Li, H.F.2    Hu, G.M.3    Wang, H.R.4    Li, Z.J.5    Lin, J.M.6
  • 44
    • 18844373863 scopus 로고    scopus 로고
    • Magnetic bead-based chemiluminescent metal immunoassay with a colloidal gold label
    • Fan A., Lau C., Lu J. Magnetic bead-based chemiluminescent metal immunoassay with a colloidal gold label. Anal. Chem. 2005, 77:3238-3242.
    • (2005) Anal. Chem. , vol.77 , pp. 3238-3242
    • Fan, A.1    Lau, C.2    Lu, J.3
  • 45
    • 84863371273 scopus 로고    scopus 로고
    • A new dual immunoassay for tumor markers based on chemiluminescence signal amplification by magnetic mesoporous silica and enzyme modified gold nanoparticles
    • Lin J., Chu P., Wei Z. A new dual immunoassay for tumor markers based on chemiluminescence signal amplification by magnetic mesoporous silica and enzyme modified gold nanoparticles. Anal. Sci. 2012, 28:21-26.
    • (2012) Anal. Sci. , vol.28 , pp. 21-26
    • Lin, J.1    Chu, P.2    Wei, Z.3
  • 46
    • 62649090591 scopus 로고    scopus 로고
    • Ultrasensitive enhanced chemiluminescence enzyme immunoassay for the determination of alpha-fetoprotein amplified by double-codified gold nanoparticles labels
    • Yang X.Y., Guo Y.S., Bi S., Zhang S.S. Ultrasensitive enhanced chemiluminescence enzyme immunoassay for the determination of alpha-fetoprotein amplified by double-codified gold nanoparticles labels. Biosens. Bioelectron. 2009, 24:2707-2711.
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 2707-2711
    • Yang, X.Y.1    Guo, Y.S.2    Bi, S.3    Zhang, S.S.4
  • 47
    • 84873689153 scopus 로고    scopus 로고
    • Flow injection chemiluminescence immunoassay of microcystin-LR by using PEI-modified magnetic beads as capturer and HRP-functionalized silica nanoparticles as signal amplifier
    • Lu J., Wei W., Yin L., Pu Y., Liu S. Flow injection chemiluminescence immunoassay of microcystin-LR by using PEI-modified magnetic beads as capturer and HRP-functionalized silica nanoparticles as signal amplifier. Analyst 2013, 138:1483-1489.
    • (2013) Analyst , vol.138 , pp. 1483-1489
    • Lu, J.1    Wei, W.2    Yin, L.3    Pu, Y.4    Liu, S.5
  • 48
    • 79960703512 scopus 로고    scopus 로고
    • Magnetic beads-based chemiluminescence substrate-resolved duplex immunoassay for sequential detection of two ischemic stroke markers with two orders of concentration difference
    • Zhang Y., Xu Q., Peng Q., Cao Z., Wang X., Lu J. Magnetic beads-based chemiluminescence substrate-resolved duplex immunoassay for sequential detection of two ischemic stroke markers with two orders of concentration difference. Anal. Sci. 2011, 27:739-740.
    • (2011) Anal. Sci. , vol.27 , pp. 739-740
    • Zhang, Y.1    Xu, Q.2    Peng, Q.3    Cao, Z.4    Wang, X.5    Lu, J.6
  • 49
    • 7044247306 scopus 로고    scopus 로고
    • Chemiluminescence sequential injection immunoassay for vitellogenin using magnetic microbeads
    • Soh N., Nishiyama H., Asano Y., Imato T., Masadome T., Kurokawa Y. Chemiluminescence sequential injection immunoassay for vitellogenin using magnetic microbeads. Talanta 2004, 64:1160-1168.
    • (2004) Talanta , vol.64 , pp. 1160-1168
    • Soh, N.1    Nishiyama, H.2    Asano, Y.3    Imato, T.4    Masadome, T.5    Kurokawa, Y.6
  • 50
    • 57249094200 scopus 로고    scopus 로고
    • Evaluation of alpha-fetoprotein (AFP) in human serum by chemiluminescence enzyme immunoassay with magnetic particles and coated tubes as solid phases
    • Zhang Q.Y., Wang X., Li Z.J., Lin J.M. Evaluation of alpha-fetoprotein (AFP) in human serum by chemiluminescence enzyme immunoassay with magnetic particles and coated tubes as solid phases. Anal. Chim. Acta 2009, 631:212-217.
    • (2009) Anal. Chim. Acta , vol.631 , pp. 212-217
    • Zhang, Q.Y.1    Wang, X.2    Li, Z.J.3    Lin, J.M.4
  • 51
    • 10044261711 scopus 로고    scopus 로고
    • Preparation of inert magnetic nano-particles for the directed immobilization of antibodies
    • Fuentes M., Mateo C., Guisan J.M., Fernandez-Lafuente R. Preparation of inert magnetic nano-particles for the directed immobilization of antibodies. Biosens. Bioelectron. 2005, 20:1380-1387.
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 1380-1387
    • Fuentes, M.1    Mateo, C.2    Guisan, J.M.3    Fernandez-Lafuente, R.4
  • 52
    • 52749088977 scopus 로고    scopus 로고
    • Covalent immobilization of antibodies on finally inert support surfaces through their surface regions having the highest densities in carboxyl groups
    • Batalla P., Fuentes M., Mateo C., Grazu V., Fernandez-Lafuente R., Guisan J.M. Covalent immobilization of antibodies on finally inert support surfaces through their surface regions having the highest densities in carboxyl groups. Biomacromolecules 2008, 9:2230-2236.
    • (2008) Biomacromolecules , vol.9 , pp. 2230-2236
    • Batalla, P.1    Fuentes, M.2    Mateo, C.3    Grazu, V.4    Fernandez-Lafuente, R.5    Guisan, J.M.6
  • 53
    • 84865308802 scopus 로고    scopus 로고
    • Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3
    • Zhang Q.-Y., Chen H., Lin Z., Lin J.-M. Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3. JPA 2011, 1:166-174.
    • (2011) JPA , vol.1 , pp. 166-174
    • Zhang, Q.-Y.1    Chen, H.2    Lin, Z.3    Lin, J.-M.4
  • 54
    • 41549087899 scopus 로고    scopus 로고
    • A channel-resolved approach coupled with magnet-captured technique for multianalyte chemiluminescent immunoassay
    • Fu Z.F., Yan F., Liu H., Lin J.H., Ju H.X. A channel-resolved approach coupled with magnet-captured technique for multianalyte chemiluminescent immunoassay. Biosens. Bioelectron. 2008, 23:1422-1428.
    • (2008) Biosens. Bioelectron. , vol.23 , pp. 1422-1428
    • Fu, Z.F.1    Yan, F.2    Liu, H.3    Lin, J.H.4    Ju, H.X.5
  • 55
    • 33947171884 scopus 로고    scopus 로고
    • Molecular analysis of magnetotactic bacteria and development of functional bacterial magnetic particles for nano-biotechnology
    • Matsunaga T., Suzuki T., Tanaka M., Arakaki A. Molecular analysis of magnetotactic bacteria and development of functional bacterial magnetic particles for nano-biotechnology. Trends Biotechnol. 2007, 25:182-188.
    • (2007) Trends Biotechnol. , vol.25 , pp. 182-188
    • Matsunaga, T.1    Suzuki, T.2    Tanaka, M.3    Arakaki, A.4
  • 56
    • 0242364235 scopus 로고    scopus 로고
    • Genes and proteins involved in bacterial magnetic particle formation
    • Matsunaga T., Okamura Y. Genes and proteins involved in bacterial magnetic particle formation. Trends Microbiol. 2003, 11:536-541.
    • (2003) Trends Microbiol. , vol.11 , pp. 536-541
    • Matsunaga, T.1    Okamura, Y.2
  • 57
    • 0034254833 scopus 로고    scopus 로고
    • Fully automated chemiluminescence immunoassay of insulin using antibody-protein A-bacterial magnetic particle complexes
    • Tanaka T., Matsunaga T. Fully automated chemiluminescence immunoassay of insulin using antibody-protein A-bacterial magnetic particle complexes. Anal. Chem. 2000, 72:3518-3522.
    • (2000) Anal. Chem. , vol.72 , pp. 3518-3522
    • Tanaka, T.1    Matsunaga, T.2
  • 58
    • 0030260484 scopus 로고    scopus 로고
    • Chemiluminescence enzyme immunoassay using bacterial magnetic particles
    • Matsunaga T., Kawasaki M., Yu X., Tsujimura N., Nakamura N. Chemiluminescence enzyme immunoassay using bacterial magnetic particles. Anal. Chem. 1996, 68:3551-3554.
    • (1996) Anal. Chem. , vol.68 , pp. 3551-3554
    • Matsunaga, T.1    Kawasaki, M.2    Yu, X.3    Tsujimura, N.4    Nakamura, N.5
  • 59
    • 0032681008 scopus 로고    scopus 로고
    • Chemiluminescence enzyme immunoassay using ProteinA-bacterial magnetite complex
    • Matsunaga T., Sato R., Kamiya S., Tanaka T., Takeyama H. Chemiluminescence enzyme immunoassay using ProteinA-bacterial magnetite complex. J. Magn. Magn. Mater. 1999, 194:126-131.
    • (1999) J. Magn. Magn. Mater. , vol.194 , pp. 126-131
    • Matsunaga, T.1    Sato, R.2    Kamiya, S.3    Tanaka, T.4    Takeyama, H.5
  • 60
    • 0021962463 scopus 로고
    • Enzymatic immunoassay of α-fetoprotein, insulin and 17-α-hydroxyprogesterone base on chemiluminescence in a flow-injection system
    • Maeda M., Tsuji A. Enzymatic immunoassay of α-fetoprotein, insulin and 17-α-hydroxyprogesterone base on chemiluminescence in a flow-injection system. Anal. Chim. Acta 1985, 167:241-248.
    • (1985) Anal. Chim. Acta , vol.167 , pp. 241-248
    • Maeda, M.1    Tsuji, A.2
  • 61
    • 49849103485 scopus 로고    scopus 로고
    • Gold nanoparticle-based immunoassay by using non-stripping chemiluminescence detection
    • Duan C.-F., Yu Y.-Q., Cui H. Gold nanoparticle-based immunoassay by using non-stripping chemiluminescence detection. Analyst 2008, 133:1250-1255.
    • (2008) Analyst , vol.133 , pp. 1250-1255
    • Duan, C.-F.1    Yu, Y.-Q.2    Cui, H.3
  • 62
    • 79952178439 scopus 로고    scopus 로고
    • Sensitive chemiluminescence immunoassay by capillary electrophoresis with gold nanoparticles
    • Liu Y.-m., Mei L., Liu L.-j., Peng L.-f., Chen Y.-h., Ren S.-w. Sensitive chemiluminescence immunoassay by capillary electrophoresis with gold nanoparticles. Anal. Chem. 2011, 83:1137-1143.
    • (2011) Anal. Chem. , vol.83 , pp. 1137-1143
    • Liu, Y.-M.1    Mei, L.2    Liu, L.-J.3    Peng, L.-F.4    Chen, Y.-H.5    Ren, S.-W.6
  • 63
    • 0031752710 scopus 로고    scopus 로고
    • Chemiluminescence detection in integrated post-separation reactors for microchip-based capillary electrophoresis and affinity electrophoresis
    • Mangru S.D., Harrison D.J. Chemiluminescence detection in integrated post-separation reactors for microchip-based capillary electrophoresis and affinity electrophoresis. Electrophoresis 1998, 19:2301-2307.
    • (1998) Electrophoresis , vol.19 , pp. 2301-2307
    • Mangru, S.D.1    Harrison, D.J.2
  • 64
    • 33645450466 scopus 로고    scopus 로고
    • Use of soybean peroxidase in chemiluminescent enzyme-linked immunosorbent assay
    • Sakharov I.Y., Alpeeva I.S., Efremov E.E. Use of soybean peroxidase in chemiluminescent enzyme-linked immunosorbent assay. J. Agric. Food. Chem. 2006, 54:1584-1587.
    • (2006) J. Agric. Food. Chem. , vol.54 , pp. 1584-1587
    • Sakharov, I.Y.1    Alpeeva, I.S.2    Efremov, E.E.3
  • 65
    • 67649381647 scopus 로고    scopus 로고
    • Immunomagnetic separation and rapid detection of bacteria using bioluminescence and microfluidics
    • Qiu J., Zhou Y., Chen H., Lin J.-M. Immunomagnetic separation and rapid detection of bacteria using bioluminescence and microfluidics. Talanta 2009, 79:787-795.
    • (2009) Talanta , vol.79 , pp. 787-795
    • Qiu, J.1    Zhou, Y.2    Chen, H.3    Lin, J.-M.4
  • 66
    • 84925835473 scopus 로고    scopus 로고
    • Comparison of chemiluminescence enzyme immunoassay based on magnetic microparticles with traditional colorimetric ELISA for the detection of serum alpha-fetoprotein
    • Zhang Q.-Y., Chen H., Lin Z., Lin J.-M. Comparison of chemiluminescence enzyme immunoassay based on magnetic microparticles with traditional colorimetric ELISA for the detection of serum alpha-fetoprotein. JPA 2012, 2:130-135.
    • (2012) JPA , vol.2 , pp. 130-135
    • Zhang, Q.-Y.1    Chen, H.2    Lin, Z.3    Lin, J.-M.4
  • 67
    • 84875409157 scopus 로고    scopus 로고
    • A novel quantum dots-based OFF-ON fluorescent biosensor for highly selective and sensitive detection of double-strand DNA
    • Liu Z., Liu S., Wang X., Li P., He Y. A novel quantum dots-based OFF-ON fluorescent biosensor for highly selective and sensitive detection of double-strand DNA. Sens. Actuators B 2013, 176:1147-1153.
    • (2013) Sens. Actuators B , vol.176 , pp. 1147-1153
    • Liu, Z.1    Liu, S.2    Wang, X.3    Li, P.4    He, Y.5
  • 69
    • 54349100420 scopus 로고    scopus 로고
    • Trends in DNA biosensors
    • Teles F.R.R., Fonseca L.P. Trends in DNA biosensors. Talanta 2008, 77:606-623.
    • (2008) Talanta , vol.77 , pp. 606-623
    • Teles, F.R.R.1    Fonseca, L.P.2
  • 70
    • 77956232564 scopus 로고    scopus 로고
    • Sequence-specific detection of short-length DNA via template-dependent surface-hybridization events
    • Cai S., Lau C., Lu J. Sequence-specific detection of short-length DNA via template-dependent surface-hybridization events. Anal. Chem. 2010, 82:7178-7184.
    • (2010) Anal. Chem. , vol.82 , pp. 7178-7184
    • Cai, S.1    Lau, C.2    Lu, J.3
  • 71
    • 80053103350 scopus 로고    scopus 로고
    • Dendrimer-based biosensor for chemiluminescent detection of DNA hybridization
    • Liu P., Hun X., Qing H. Dendrimer-based biosensor for chemiluminescent detection of DNA hybridization. Microchim. Acta 2011, 175:201-207.
    • (2011) Microchim. Acta , vol.175 , pp. 201-207
    • Liu, P.1    Hun, X.2    Qing, H.3
  • 72
    • 77249174859 scopus 로고    scopus 로고
    • Highly sensitive non-stripping gold nanoparticles-based chemiluminescent detection of DNA hybridization coupled to magnetic beads
    • Cai S., Xin L., Lau C.W., Lu J.Z. Highly sensitive non-stripping gold nanoparticles-based chemiluminescent detection of DNA hybridization coupled to magnetic beads. Analyst 2010, 135:615-620.
    • (2010) Analyst , vol.135 , pp. 615-620
    • Cai, S.1    Xin, L.2    Lau, C.W.3    Lu, J.Z.4
  • 74
    • 84855271164 scopus 로고    scopus 로고
    • Chemiluminescent detection of DNA hybridization based on signal DNA probe modified with gold and cobalt nanoparticles
    • Chen L., Zhang L., Qiu T., Cao W. Chemiluminescent detection of DNA hybridization based on signal DNA probe modified with gold and cobalt nanoparticles. Int. J. Electrochem. Sci. 2011, 6:5325-5336.
    • (2011) Int. J. Electrochem. Sci. , vol.6 , pp. 5325-5336
    • Chen, L.1    Zhang, L.2    Qiu, T.3    Cao, W.4
  • 75
    • 76749145140 scopus 로고    scopus 로고
    • Chemiluminescence DNA biosensor based on dual-amplification of thrombin and thiocyanuric acid-gold nanoparticle network
    • Li X., Li W., Zhang S. Chemiluminescence DNA biosensor based on dual-amplification of thrombin and thiocyanuric acid-gold nanoparticle network. Analyst 2010, 135:332-336.
    • (2010) Analyst , vol.135 , pp. 332-336
    • Li, X.1    Li, W.2    Zhang, S.3
  • 76
    • 49849090499 scopus 로고    scopus 로고
    • Carrier-resolved technology for homogeneous and multiplexed DNA assays in a 'one-pot reaction'
    • Li H., Lau C., Lu J. Carrier-resolved technology for homogeneous and multiplexed DNA assays in a 'one-pot reaction'. Analyst 2008, 133:1229-1236.
    • (2008) Analyst , vol.133 , pp. 1229-1236
    • Li, H.1    Lau, C.2    Lu, J.3
  • 77
    • 41149129692 scopus 로고    scopus 로고
    • Instantaneous derivatization technology for simultaneous and homogeneous determination of multiple DNA targets
    • Miao J., Cao Z., Zhou Y., Lau C., Lu J. Instantaneous derivatization technology for simultaneous and homogeneous determination of multiple DNA targets. Anal. Chem. 2008, 80:1606-1613.
    • (2008) Anal. Chem. , vol.80 , pp. 1606-1613
    • Miao, J.1    Cao, Z.2    Zhou, Y.3    Lau, C.4    Lu, J.5
  • 78
    • 77956737857 scopus 로고    scopus 로고
    • G-rich sequence-functionalized polystyrene microsphere-based instantaneous derivatization for the chemiluminescent amplified detection of DNA
    • Xin L., Cao Z., Lau C., Kai M., Lu J. G-rich sequence-functionalized polystyrene microsphere-based instantaneous derivatization for the chemiluminescent amplified detection of DNA. Luminescence 2010, 25:336-342.
    • (2010) Luminescence , vol.25 , pp. 336-342
    • Xin, L.1    Cao, Z.2    Lau, C.3    Kai, M.4    Lu, J.5
  • 79
    • 84875533490 scopus 로고    scopus 로고
    • Molecularly-imprinted polymers as a versatile, highly selective tool in sample preparation, TrAC
    • Martin-Esteban A. Molecularly-imprinted polymers as a versatile, highly selective tool in sample preparation, TrAC. Trends Anal. Chem. 2013, 45:169-181.
    • (2013) Trends Anal. Chem. , vol.45 , pp. 169-181
    • Martin-Esteban, A.1
  • 80
    • 0032658841 scopus 로고    scopus 로고
    • Molecularly imprinted sorbent assays and the use of non-related probes
    • Haupt K. Molecularly imprinted sorbent assays and the use of non-related probes. React. Funct. Polym. 1999, 41:125-131.
    • (1999) React. Funct. Polym. , vol.41 , pp. 125-131
    • Haupt, K.1
  • 81
    • 84856499271 scopus 로고    scopus 로고
    • Surface imprinted thin polymer film systems with selective recognition for bovine serum albumin
    • Kryscio D.R., Peppas N.A. Surface imprinted thin polymer film systems with selective recognition for bovine serum albumin. Anal. Chim. Acta 2012, 718:109-115.
    • (2012) Anal. Chim. Acta , vol.718 , pp. 109-115
    • Kryscio, D.R.1    Peppas, N.A.2
  • 82
    • 84861652802 scopus 로고    scopus 로고
    • Direct fluorimetric sensing of UV-excited analytes in biological and environmental samples using molecularly imprinted polymer nanoparticles and fluorescence polarization
    • Ton X.-A., Acha V., Haupt K., Tse Sum Bui B. Direct fluorimetric sensing of UV-excited analytes in biological and environmental samples using molecularly imprinted polymer nanoparticles and fluorescence polarization. Biosens. Bioelectron. 2012, 36:22-28.
    • (2012) Biosens. Bioelectron. , vol.36 , pp. 22-28
    • Ton, X.-A.1    Acha, V.2    Haupt, K.3    Tse Sum Bui, B.4
  • 84
    • 84861959892 scopus 로고    scopus 로고
    • s) adsorbents for effective extraction and determination of sulfonamides in the poultry feed
    • s) adsorbents for effective extraction and determination of sulfonamides in the poultry feed. J. Chromatogr. A 2012, 1245:8-16.
    • (2012) J. Chromatogr. A , vol.1245 , pp. 8-16
    • Kong, X.1    Gao, R.2    He, X.3    Chen, L.4    Zhang, Y.5
  • 85
    • 84867034558 scopus 로고    scopus 로고
    • Flow injection chemiluminescence sensor based on core-shell magnetic molecularly imprinted nanoparticles for determination of chrysoidine in food samples
    • Lu F., Sun M., Fan L., Qiu H., Li X., Luo C. Flow injection chemiluminescence sensor based on core-shell magnetic molecularly imprinted nanoparticles for determination of chrysoidine in food samples. Sens. Actuators, B: Chem. 2012, 173:591-598.
    • (2012) Sens. Actuators, B: Chem. , vol.173 , pp. 591-598
    • Lu, F.1    Sun, M.2    Fan, L.3    Qiu, H.4    Li, X.5    Luo, C.6
  • 86
    • 79954630509 scopus 로고    scopus 로고
    • Rapid and selective determination of urinary lysozyme based on magnetic molecularly imprinted polymers extraction followed by chemiluminescence detection
    • Jing T., Xia H., Guan Q., Lu W., Dai Q., Niu J., Lim J.-M., Hao Q., Lee Y.-I., Zhou Y., Mei S. Rapid and selective determination of urinary lysozyme based on magnetic molecularly imprinted polymers extraction followed by chemiluminescence detection. Anal. Chim. Acta 2011, 692:73-79.
    • (2011) Anal. Chim. Acta , vol.692 , pp. 73-79
    • Jing, T.1    Xia, H.2    Guan, Q.3    Lu, W.4    Dai, Q.5    Niu, J.6    Lim, J.-M.7    Hao, Q.8    Lee, Y.-I.9    Zhou, Y.10    Mei, S.11
  • 87
    • 84865549392 scopus 로고    scopus 로고
    • A chemiluminescence array sensor based on graphene-magnetite-molecularly imprinted polymers for determination of benzenediol isomers
    • Qiu H., Luo C., Sun M., Lu F., Fan L., Li X. A chemiluminescence array sensor based on graphene-magnetite-molecularly imprinted polymers for determination of benzenediol isomers. Anal. Chim. Acta 2012, 744:75-81.
    • (2012) Anal. Chim. Acta , vol.744 , pp. 75-81
    • Qiu, H.1    Luo, C.2    Sun, M.3    Lu, F.4    Fan, L.5    Li, X.6
  • 88
    • 84862759506 scopus 로고    scopus 로고
    • A chemiluminescence sensor for determination of epinephrine using graphene oxide-magnetite-molecularly imprinted polymers
    • Qiu H., Luo C., Sun M., Lu F., Fan L., Li X. A chemiluminescence sensor for determination of epinephrine using graphene oxide-magnetite-molecularly imprinted polymers. Carbon 2012, 50:4052-4060.
    • (2012) Carbon , vol.50 , pp. 4052-4060
    • Qiu, H.1    Luo, C.2    Sun, M.3    Lu, F.4    Fan, L.5    Li, X.6
  • 89
    • 84865678313 scopus 로고    scopus 로고
    • Determination of L-tryptophan based on graphene oxide-magnetite-molecularly imprinted polymers and chemiluminescence
    • Qiu H., Luo C., Sun M., Lu F., Fan L., Li X. Determination of L-tryptophan based on graphene oxide-magnetite-molecularly imprinted polymers and chemiluminescence. Talanta 2012, 98:226-230.
    • (2012) Talanta , vol.98 , pp. 226-230
    • Qiu, H.1    Luo, C.2    Sun, M.3    Lu, F.4    Fan, L.5    Li, X.6
  • 90
    • 70349286144 scopus 로고    scopus 로고
    • Bio-bar-code functionalized magnetic nanoparticle label for ultrasensitive flow injection chemiluminescence detection of DNA hybridization
    • Bi S., Zhou H., Zhang S. Bio-bar-code functionalized magnetic nanoparticle label for ultrasensitive flow injection chemiluminescence detection of DNA hybridization. Chem. Commun. 2009, 37:5567-5569.
    • (2009) Chem. Commun. , vol.37 , pp. 5567-5569
    • Bi, S.1    Zhou, H.2    Zhang, S.3
  • 91
    • 79952423264 scopus 로고    scopus 로고
    • A novel synergistic enhanced chemiluminescence achieved by a multiplex nanoprobe for biological applications combined with dual-amplification of magnetic nanoparticles
    • Bi S., Zhou H., Zhang S. A novel synergistic enhanced chemiluminescence achieved by a multiplex nanoprobe for biological applications combined with dual-amplification of magnetic nanoparticles. Chem. Sci. 2010, 1:681-687.
    • (2010) Chem. Sci. , vol.1 , pp. 681-687
    • Bi, S.1    Zhou, H.2    Zhang, S.3
  • 93
    • 77955413374 scopus 로고    scopus 로고
    • 4 magnetic nanoparticles as catalyst for the luminol chemiluminescence system and their applications in hydrogen peroxide detection
    • 4 magnetic nanoparticles as catalyst for the luminol chemiluminescence system and their applications in hydrogen peroxide detection. Talanta 2010, 82:377-383.
    • (2010) Talanta , vol.82 , pp. 377-383
    • He, S.H.1    Shi, W.B.2    Zhang, X.D.3    Li, J.A.4    Huang, Y.M.5
  • 94
    • 84867231219 scopus 로고    scopus 로고
    • 4 magnetic nanoparticles on the chemiluminescence enhancement of luminol-Ag(III) complex for rapid and sensitive determination of cysteine in human serum
    • 4 magnetic nanoparticles on the chemiluminescence enhancement of luminol-Ag(III) complex for rapid and sensitive determination of cysteine in human serum. Luminescence 2012, 27:390-397.
    • (2012) Luminescence , vol.27 , pp. 390-397
    • Rezaei, B.1    Ensafi, A.A.2    Zarei, L.3    Kameli, P.4
  • 95
    • 80052951276 scopus 로고    scopus 로고
    • 4 magnetic nanoparticles as a peroxidase mimic mediated chemiluminescence for hydrogen peroxide and glucose
    • 4 magnetic nanoparticles as a peroxidase mimic mediated chemiluminescence for hydrogen peroxide and glucose. Chem. Commun. 2011, 47:10785-10787.
    • (2011) Chem. Commun. , vol.47 , pp. 10785-10787
    • Shi, W.1    Zhang, X.2    He, S.3    Huang, Y.4
  • 96
    • 84873132820 scopus 로고    scopus 로고
    • 4 nanoparticles as oxidase mimic-mediated chemiluminescence of aqueous luminol for sulfite in white wines
    • 4 nanoparticles as oxidase mimic-mediated chemiluminescence of aqueous luminol for sulfite in white wines. J. Agric. Food. Chem. 2013, 61:840-847.
    • (2013) J. Agric. Food. Chem. , vol.61 , pp. 840-847
    • Zhang, X.1    He, S.2    Chen, Z.3    Huang, Y.4
  • 97
    • 84874077877 scopus 로고    scopus 로고
    • 4 magnetic nanoparticles as a catalyst for fast chemiluminescence determination of glutathione in human blood using luminol-diperiodatoargentate(III) system
    • 4 magnetic nanoparticles as a catalyst for fast chemiluminescence determination of glutathione in human blood using luminol-diperiodatoargentate(III) system. J. Braz. Chem. Soc. 2012, 23:2248-2257.
    • (2012) J. Braz. Chem. Soc. , vol.23 , pp. 2248-2257
    • Rezaei, B.1    Ensafi, A.A.2    Haghighatnia, F.3    Aalaye, S.E.4
  • 98
    • 67650963682 scopus 로고    scopus 로고
    • Chemiluminescent determination of H2O2 using 4-(1,2,4-triazol-1-yl)phenol as an enhancer based on the immobilization of horseradish peroxidase onto magnetic beads
    • Yang X.Y., Guo Y.S., Mei Z.H. Chemiluminescent determination of H2O2 using 4-(1,2,4-triazol-1-yl)phenol as an enhancer based on the immobilization of horseradish peroxidase onto magnetic beads. Anal. Biochem. 2009, 393:56-61.
    • (2009) Anal. Biochem. , vol.393 , pp. 56-61
    • Yang, X.Y.1    Guo, Y.S.2    Mei, Z.H.3
  • 99
    • 79960558805 scopus 로고    scopus 로고
    • Chemiluminescence aptasensor for cocaine based on double-functionalized gold nanoprobes and functionalized magnetic microbeads
    • Li Y., Ji X., Liu B. Chemiluminescence aptasensor for cocaine based on double-functionalized gold nanoprobes and functionalized magnetic microbeads. Anal. Bioanal. Chem. 2011, 401:213-219.
    • (2011) Anal. Bioanal. Chem. , vol.401 , pp. 213-219
    • Li, Y.1    Ji, X.2    Liu, B.3
  • 100
    • 84855401861 scopus 로고    scopus 로고
    • L-Argininamide biosensor based on S1 nuclease hydrolysis signal amplification
    • Hun X., Wang Z. L-Argininamide biosensor based on S1 nuclease hydrolysis signal amplification. Microchim. Acta 2012, 176:209-216.
    • (2012) Microchim. Acta , vol.176 , pp. 209-216
    • Hun, X.1    Wang, Z.2
  • 101
    • 75749157812 scopus 로고    scopus 로고
    • Comparison of multiplex immunoassay platforms
    • Fu Q., Zhu J., Van Eyk J.E. Comparison of multiplex immunoassay platforms. Clin. Chem. 2010, 56:314-318.
    • (2010) Clin. Chem. , vol.56 , pp. 314-318
    • Fu, Q.1    Zhu, J.2    Van Eyk, J.E.3
  • 102
    • 65249147169 scopus 로고    scopus 로고
    • Chemiluminescence as one of the techniques used to study the antioxidative activity of blood, saliva, tear, and urine
    • (21-22+35-36)
    • Kamilov R.F., Khanov T.V., Yappamv R.N., Shakirov D.F. Chemiluminescence as one of the techniques used to study the antioxidative activity of blood, saliva, tear, and urine. Klinichescheskaya Laboratornaya Diagnostika 2009, 2. (21-22+35-36).
    • (2009) Klinichescheskaya Laboratornaya Diagnostika , vol.2
    • Kamilov, R.F.1    Khanov, T.V.2    Yappamv, R.N.3    Shakirov, D.F.4
  • 103
    • 77952237339 scopus 로고    scopus 로고
    • Development of magnetic particle-based chemiluminescence enzyme immunoassay for the detection of 17 beta-estradiol in environmental water
    • Xin T.-B., Wang X., Jin H., Liang S.-X., Lin J.-M., Li Z.-J. Development of magnetic particle-based chemiluminescence enzyme immunoassay for the detection of 17 beta-estradiol in environmental water. Appl. Biochem. Biotechnol. 2009, 158:582-594.
    • (2009) Appl. Biochem. Biotechnol. , vol.158 , pp. 582-594
    • Xin, T.-B.1    Wang, X.2    Jin, H.3    Liang, S.-X.4    Lin, J.-M.5    Li, Z.-J.6
  • 104
    • 84862811137 scopus 로고    scopus 로고
    • Chemiluminescent determination of the activity of caspase-3 using a specific peptide substrate and magnetic beads
    • Li Y. Chemiluminescent determination of the activity of caspase-3 using a specific peptide substrate and magnetic beads. Microchim. Acta 2012, 177:443-447.
    • (2012) Microchim. Acta , vol.177 , pp. 443-447
    • Li, Y.1
  • 105
    • 0344100097 scopus 로고    scopus 로고
    • A chemiluminescence biosensor coupled with immunomagnetic separation for rapid detection of Salmonella typhimurium
    • Varshney M., Li Y., Nanapanneni R., Johnson M.G., Griffis C.L. A chemiluminescence biosensor coupled with immunomagnetic separation for rapid detection of Salmonella typhimurium. J. Rapid Methods Autom. Microbiol. 2003, 11:111-131.
    • (2003) J. Rapid Methods Autom. Microbiol. , vol.11 , pp. 111-131
    • Varshney, M.1    Li, Y.2    Nanapanneni, R.3    Johnson, M.G.4    Griffis, C.L.5
  • 106
    • 64249129998 scopus 로고    scopus 로고
    • Application of magnetic nanoparticles in full-automated chemiluminescent enzyme immunoassay
    • Xie X., Ohnishi N., Takahashi Y., Kondo A. Application of magnetic nanoparticles in full-automated chemiluminescent enzyme immunoassay. J. Magn. Magn. Mater. 2009, 321:1686-1688.
    • (2009) J. Magn. Magn. Mater. , vol.321 , pp. 1686-1688
    • Xie, X.1    Ohnishi, N.2    Takahashi, Y.3    Kondo, A.4
  • 107
    • 77953287124 scopus 로고    scopus 로고
    • Development of a highly sensitive magnetic particle-based chemiluminescence enzyme immunoassay for thyroid stimulating hormone and comparison with two other immunoassays
    • Xiao Q., Li H., Lin J.-M. Development of a highly sensitive magnetic particle-based chemiluminescence enzyme immunoassay for thyroid stimulating hormone and comparison with two other immunoassays. Clin. Chim. Acta 2010, 411:1151-1153.
    • (2010) Clin. Chim. Acta , vol.411 , pp. 1151-1153
    • Xiao, Q.1    Li, H.2    Lin, J.-M.3
  • 108
    • 0001187357 scopus 로고
    • Development of a magnetic particle-based automated chemiluminescent immunoassay for triasulfuron
    • Schlaeppi J.M.A., Kessler A., Fory W. Development of a magnetic particle-based automated chemiluminescent immunoassay for triasulfuron. J. Agric. Food. Chem. 1994, 42:1914-1919.
    • (1994) J. Agric. Food. Chem. , vol.42 , pp. 1914-1919
    • Schlaeppi, J.M.A.1    Kessler, A.2    Fory, W.3
  • 109
    • 30744477969 scopus 로고    scopus 로고
    • Magnetic bead-based chemiluminescence detection of sequence-specific DNA by using catalytic nucleic acid labels
    • Cao Z.J., Li Z.X., Zhao Y.J., Song Y.M., Lu J.Z. Magnetic bead-based chemiluminescence detection of sequence-specific DNA by using catalytic nucleic acid labels. Anal. Chim. Acta 2006, 557:152-158.
    • (2006) Anal. Chim. Acta , vol.557 , pp. 152-158
    • Cao, Z.J.1    Li, Z.X.2    Zhao, Y.J.3    Song, Y.M.4    Lu, J.Z.5
  • 110
    • 67149086838 scopus 로고    scopus 로고
    • Magnetic bead-based DNA hybridization assay with chemiluminescence and chemiluminescent imaging detection
    • Li H., He Z. Magnetic bead-based DNA hybridization assay with chemiluminescence and chemiluminescent imaging detection. Analyst 2009, 134:800-804.
    • (2009) Analyst , vol.134 , pp. 800-804
    • Li, H.1    He, Z.2
  • 111
    • 38649135734 scopus 로고    scopus 로고
    • Colloidal gold-polystyrene bead hybrid for chemiluminescent detection of sequence-specific DNA
    • Fan A., Lau C., Lu J. Colloidal gold-polystyrene bead hybrid for chemiluminescent detection of sequence-specific DNA. Analyst 2008, 133:219-225.
    • (2008) Analyst , vol.133 , pp. 219-225
    • Fan, A.1    Lau, C.2    Lu, J.3
  • 112
    • 84862790952 scopus 로고    scopus 로고
    • Flow injection chemiluminescence sensor based on core-shell magnetic molecularly imprinted nanoparticles for determination of sulfadiazine
    • Lu F., Li H., Sun M., Fan L., Qiu H., Li X., Luo C. Flow injection chemiluminescence sensor based on core-shell magnetic molecularly imprinted nanoparticles for determination of sulfadiazine. Anal. Chim. Acta 2012, 718:84-91.
    • (2012) Anal. Chim. Acta , vol.718 , pp. 84-91
    • Lu, F.1    Li, H.2    Sun, M.3    Fan, L.4    Qiu, H.5    Li, X.6    Luo, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.