메뉴 건너뛰기




Volumn 60, Issue 8, 2013, Pages 1719-1731

Multi-transmit beam forming for fast cardiac imaging-a simulation study

Author keywords

[No Author keywords available]

Indexed keywords

CONVENTIONAL BEAM FORMING; CROSS-TALK LEVELS; DIAGNOSTIC VALUE; HIGH TEMPORAL RESOLUTION; RECEIVE BEAMFORMING; SIMULATION STUDIES; TRANSDUCER CONFIGURATION; WINDOWING FUNCTION;

EID: 84881499910     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2013.2753     Document Type: Article
Times cited : (83)

References (21)
  • 1
    • 0021419747 scopus 로고
    • Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays
    • D. P. Shattuck, M. D. Weinshenker, S. W. Smith, and O. T. von Ramm, "Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays," J. Acoust. Soc. Am., vol. 75, no. 4, pp. 1273-1282, 1984. (Pubitemid 14139208)
    • (1984) Journal of the Acoustical Society of America , vol.75 , Issue.4 , pp. 1273-1282
    • Shattuck, D.P.1    Weinshenker, M.D.2    Smith, S.W.3    Von Ramm, O.T.4
  • 2
    • 0026128878 scopus 로고
    • High-speed ultrasound volumetric imaging system-Part II: Parallel processing and image display
    • Mar
    • O. T. von Ramm, S. W. Smith, and H. G. Pavy, "High-speed ultrasound volumetric imaging system-Part II: Parallel processing and image display," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 38, no. 2, pp. 109-115, Mar. 1991.
    • (1991) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.38 , Issue.2 , pp. 109-115
    • Von Ramm, O.T.1    Smith, S.W.2    Pavy, H.G.3
  • 4
  • 5
    • 65349145884 scopus 로고    scopus 로고
    • Coherent plane-wave compounding for very high-frame rate ultrasonography and transient elastography
    • G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, "Coherent plane-wave compounding for very high-frame rate ultrasonography and transient elastography," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no. 3, pp. 489-506, 2009.
    • (2009) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.56 , Issue.3 , pp. 489-506
    • Montaldo, G.1    Tanter, M.2    Bercoff, J.3    Benech, N.4    Fink, M.5
  • 6
    • 80052726520 scopus 로고    scopus 로고
    • High-frame-rate echocardiography using diverging transmit beams and parallel receive beam forming
    • H. Hasegawa and H. Kanai, "High-frame-rate echocardiography using diverging transmit beams and parallel receive beam forming," J. Med. Ultrasound, vol. 38, no. 3, pp. 129-140, 2011.
    • (2011) J. Med. Ultrasound , vol.38 , Issue.3 , pp. 129-140
    • Hasegawa, H.1    Kanai, H.2
  • 9
    • 85039444936 scopus 로고
    • Improved imaging rate through simultaneous transmission of several ultrasound beams
    • R. Mallart and M. Fink, "Improved imaging rate through simultaneous transmission of several ultrasound beams," Proc. SPIE, 1992, vol. 1733, pp. 120-130.
    • (1992) Proc. SPIE , vol.1733 , pp. 120-130
    • Mallart, R.1    Fink, M.2
  • 11
    • 0015022405 scopus 로고
    • The time-dependent force and radiation impedance on a piston in a rigid infinite planar baffle
    • P. R. Stepanishen, "The time-dependent force and radiation impedance on a piston in a rigid infinite planar baffle," J. Acoust. Soc. Am., vol. 49, no. 5B, pp. 1629-1638, 1971.
    • (1971) J. Acoust. Soc. Am , vol.49 , Issue.5 B , pp. 1629-1638
    • Stepanishen, P.R.1
  • 13
    • 84881520567 scopus 로고    scopus 로고
    • Ph.D thesis, Dept. of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
    • T. Bjastad, "High frame rate ultrasound imaging using parallel beamforming," Ph.D thesis, Dept. of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway, 2009.
    • (2009) High Frame Rate Ultrasound Imaging Using Parallel Beamforming
    • Bjastad, T.1
  • 14
    • 84865311326 scopus 로고    scopus 로고
    • Comparison of conventional parallel beamforming with plan wave and diverging wave imaging for cardiac applications: A simulation study
    • L. Tong, H. Gao, and H. F. Choi, "Comparison of conventional parallel beamforming with plan wave and diverging wave imaging for cardiac applications: A simulation study," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 59, no. 8, pp. 1654-1663, 2012.
    • (2012) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.59 , Issue.8 , pp. 1654-1663
    • Tong, L.1    Gao, H.2    Choi, H.F.3
  • 16
    • 15844362336 scopus 로고    scopus 로고
    • Use of modulated excitation signals in medical ultrasound. Part III: High frame rate imaging
    • T. Misaridis and J. A. Jensen, "Use of modulated excitation signals in medical ultrasound. Part III: High frame rate imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 52, no. 2, pp. 208-219, 2005.
    • (2005) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.52 , Issue.2 , pp. 208-219
    • Misaridis, T.1    Jensen, J.A.2
  • 19
    • 84881534058 scopus 로고    scopus 로고
    • Lecoeur Electronique Jun [Online] Available
    • L ecoeur Electronique. (2013, Jun.) Open system. [Online]. Available: http://www.lecoeur-electronique.net/crbst-45.html
    • (2013) Open System


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.