메뉴 건너뛰기




Volumn 26, Issue 6, 2013, Pages 316-320

Comparison of the pedicle screws placement between electronic conductivity device and normal pedicle finder in posterior surgery of scoliosis

Author keywords

electronic conductivity device; navigation; pedicle finder; pedicle screws; scoliosis

Indexed keywords

ADOLESCENT; ADOLESCENT IDIOPATHIC SCOLIOSIS; ADULT; ARTICLE; CHILD; CLINICAL ARTICLE; COBB ANGLE; CONTROLLED STUDY; ELECTRIC CONDUCTIVITY; ELECTRONIC CONDUCTIVITY DEVICE; FEMALE; HUMAN; MALE; MEDICAL DEVICE COMPLICATION; NORMAL PEDICLE FINDER; PEDICLE SCREW; PEDICLE SCREW PERFORATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; SCHOOL CHILD; SURGICAL DRILL; SURGICAL TECHNIQUE;

EID: 84881477842     PISSN: 15360652     EISSN: 15392465     Source Type: Journal    
DOI: 10.1097/BSD.0b013e318247f21d     Document Type: Article
Times cited : (28)

References (24)
  • 1
    • 0033794424 scopus 로고    scopus 로고
    • The use of pedicle-screw internal fixation for the operative treatment of spinal disorders
    • Gaines RW. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am. 2000;82-A:1458-1476.
    • (2000) J Bone Joint Surg Am , vol.82 A , pp. 1458-1476
    • Gaines, R.W.1
  • 2
    • 0028567083 scopus 로고
    • Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis
    • Suk SI, Lee CK, Min HJ, et al. Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop. 1994;18:341-346.
    • (1994) Int Orthop , vol.18 , pp. 341-346
    • Suk, S.I.1    Lee, C.K.2    Min, H.J.3
  • 3
    • 0037099509 scopus 로고    scopus 로고
    • Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities
    • Belmont PJ Jr, Klemme WR, Robinson M, et al. Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine. 2002;27:1558-1566.
    • (2002) Spine , vol.27 , pp. 1558-1566
    • Belmont Jr., P.J.1    Klemme, W.R.2    Robinson, M.3
  • 4
    • 0035884966 scopus 로고    scopus 로고
    • Thoracic pedicle screw fixation in spinal deformities: Are they really safe?
    • Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine. 2001;26:2049-2057.
    • (2001) Spine , vol.26 , pp. 2049-2057
    • Suk, S.I.1    Kim, W.J.2    Lee, S.M.3
  • 5
    • 0022501586 scopus 로고
    • Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: A case report
    • Jendrisak MD. Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: a case report. Surgery. 1986; 99:631-633.
    • (1986) Surgery , vol.99 , pp. 631-633
    • Jendrisak, M.D.1
  • 6
    • 36148985762 scopus 로고    scopus 로고
    • Electrical conductivity measurement: A new technique to detect iatrogenic initial pedicle perforation
    • Bolger C, Kelleher MO, McEvoy L, et al. Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforation. Eur Spine J. 2007;16:1919-1924.
    • (2007) Eur Spine J , vol.16 , pp. 1919-1924
    • Bolger, C.1    Kelleher, M.O.2    McEvoy, L.3
  • 7
    • 0022634973 scopus 로고
    • An internal fixator for posterior application to short segments of the thoracic, lumbar or lumbosacral spine
    • Krag MH, Beynnon BD, Pope MH, et al. An internal fixator for posterior application to short segments of the thoracic, lumbar or lumbosacral spine. Clin Orthop. 1986;203:75-98.
    • (1986) Clin Orthop , vol.203 , pp. 75-98
    • Krag, M.H.1    Beynnon, B.D.2    Pope, M.H.3
  • 8
    • 0022628372 scopus 로고
    • A biomechanical study of intrapedicular screw fixation in the lumbosacral spine
    • Zindrick MR, Wiltse LL, Widell EH, et al. A biomechanical study of intrapedicular screw fixation in the lumbosacral spine. Clin Orthop. 1986;203:99-112.
    • (1986) Clin Orthop , vol.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3
  • 9
    • 0345357712 scopus 로고    scopus 로고
    • Inter-and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement
    • Rao G, Brodke DS, Rondina M, et al. Inter-and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement. Spine. 2003;28:2527-2530.
    • (2003) Spine , vol.28 , pp. 2527-2530
    • Rao, G.1    Brodke, D.S.2    Rondina, M.3
  • 10
    • 0034665136 scopus 로고    scopus 로고
    • Pedicle morphology in thoracic adolescent idiopathic scoliosis: Is pedicle fixation an anatomically viable technique?
    • O'Brien MF, Lenke LG, Mardjetko S, et al. Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique? Spine. 2000;25:228-293.
    • (2000) Spine , vol.25 , pp. 228-293
    • O'Brien, M.F.1    Lenke, L.G.2    Mardjetko, S.3
  • 11
    • 0028809111 scopus 로고
    • Horizontal plane morphometry of normal and scoliotic vertebrae
    • Xiong B, Sevastik B, Sevastik J, et al. Horizontal plane morphometry of normal and scoliotic vertebrae. Eur Spine J. 1995;4:6-10.
    • (1995) Eur Spine J , vol.4 , pp. 6-10
    • Xiong, B.1    Sevastik, B.2    Sevastik, J.3
  • 12
    • 0742269914 scopus 로고    scopus 로고
    • Free hand pedicle screw placement in the thoracic spine: Is it safe?
    • Kim YJ, Lenke LG, Bridwell KH, et al. Free hand pedicle screw placement in the thoracic spine: is it safe? Spine. 2004;29:333-342.
    • (2004) Spine , vol.29 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3
  • 13
    • 0029549201 scopus 로고
    • Intraoperative stimulation of pedicle screws: A new method for verification of screw placement
    • Young WF, Morledge DE, Martin W, et al. Intraoperative stimulation of pedicle screws: a new method for verification of screw placement. Surg Neurol. 1995;44:544-547.
    • (1995) Surg Neurol , vol.44 , pp. 544-547
    • Young, W.F.1    Morledge, D.E.2    Martin, W.3
  • 14
    • 0034032420 scopus 로고    scopus 로고
    • Image-guided surgery: Applications to the cervical and thoracic spine and a review of the first 120 procedures
    • Bolger C, Wigfield C. Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg. 2000;92(2 suppl):175-180.
    • (2000) J Neurosurg , vol.92 , Issue.2 SUPPL. , pp. 175-180
    • Bolger, C.1    Wigfield, C.2
  • 15
    • 80052670389 scopus 로고    scopus 로고
    • PediGuard: A solution for the challenges of pedicle screw placement
    • Betz RR, Samdani AF, Djurasovic M, et al. PediGuard: a solution for the challenges of pedicle screw placement. J Orthop Surg Sports Med. 2008;3:18-22.
    • (2008) J Orthop Surg Sports Med , vol.3 , pp. 18-22
    • Betz, R.R.1    Samdani, A.F.2    Djurasovic, M.3
  • 16
    • 34250782220 scopus 로고    scopus 로고
    • Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: Comparison between conventional fluoroscopic and computer-assisted technique
    • Kotani Y, Abumi K, Ito M, et al. Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine. 2007;32:1543-1550.
    • (2007) Spine , vol.32 , pp. 1543-1550
    • Kotani, Y.1    Abumi, K.2    Ito, M.3
  • 17
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M, et al. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine. 2000;25:606-614.
    • (2000) Spine , vol.25 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3
  • 18
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomized controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoshi M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomized controlled clinical study in 100 consecutive patients. Eur Spine J. 2000;9:235-240.
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoshi, M.3
  • 19
    • 0035065411 scopus 로고    scopus 로고
    • Stereotactic navigation for placement of pedicle screws in the thoracic spine
    • Youkilis AS, Quint DJ, McGillicuddy JE, et al. Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery. 2001;48:771-779.
    • (2001) Neurosurgery , vol.48 , pp. 771-779
    • Youkilis, A.S.1    Quint, D.J.2    McGillicuddy, J.E.3
  • 20
    • 78649282684 scopus 로고    scopus 로고
    • Learning curve of computerassisted navigation system in spine surgery
    • Bai YS, Zhang Y, Chen ZQ, et al. Learning curve of computerassisted navigation system in spine surgery. Chin Med J (Engl). 2010;123:2989-2994.
    • (2010) Chin Med J (Engl) , vol.123 , pp. 2989-2994
    • Bai, Y.S.1    Zhang, Y.2    Chen, Z.Q.3
  • 21
    • 80052661453 scopus 로고    scopus 로고
    • The contribution of an electronic conductivity device to the safety of pedicle screw insertion in scoliosis surgery
    • Ovadia D, Korn A, Fishkin M, et al. The contribution of an electronic conductivity device to the safety of pedicle screw insertion in scoliosis surgery. Spine. 2011;36:E1314-E1321.
    • (2011) Spine , vol.36
    • Ovadia, D.1    Korn, A.2    Fishkin, M.3
  • 22
    • 70349675777 scopus 로고    scopus 로고
    • In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device
    • Koller H, Hitzl W, Acosta F, et al. In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device. Eur Spine J. 2009;18:1300-1313.
    • (2009) Eur Spine J , vol.18 , pp. 1300-1313
    • Koller, H.1    Hitzl, W.2    Acosta, F.3
  • 23
    • 70349655228 scopus 로고    scopus 로고
    • Technique for drilling instrument monitoring electrical conductivity in pediatric cervical spine screw insertion: A preliminary report
    • Zeller R, Canavese F, Kulkarni AV, et al. Technique for drilling instrument monitoring electrical conductivity in pediatric cervical spine screw insertion: a preliminary report. J Pediatr Orthop. 2009;29:760-764.
    • (2009) J Pediatr Orthop , vol.29 , pp. 760-764
    • Zeller, R.1    Canavese, F.2    Kulkarni, A.V.3
  • 24


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.