메뉴 건너뛰기




Volumn , Issue , 2013, Pages 325-330

Wearable biopotential measurement using the TI ADS1198 analog front-end and textile electrodes

Author keywords

biopotential measurement; e textiles; ECG; EMG

Indexed keywords

ANALOG FRONT-END; BIOPOTENTIAL MEASUREMENT; E-TEXTILES; EMG; INTEGRATED ELECTRODES; SIGNAL MONITORING; TEXAS INSTRUMENTS; TEXTILE ELECTRODES;

EID: 84881353089     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MeMeA.2013.6549761     Document Type: Conference Paper
Times cited : (11)

References (14)
  • 1
    • 84881324554 scopus 로고    scopus 로고
    • Biosignal monitoring implemented in a swimsuit for athlete performance evaluation
    • 8-10th June, Mulhouse, France
    • Catarino A., Carvalho H., Rocha A. M., Montagna G., Dias M. J., "Biosignal monitoring implemented in a swimsuit for athlete performance evaluation", Proceedings of AUTEX 2011 Conference, 8-10th June 2011,Mulhouse, France, pp 807-813
    • (2011) Proceedings of AUTEX 2011 Conference , pp. 807-813
    • Catarino, A.1    Carvalho, H.2    Rocha, A.M.3    Montagna, G.4    Dias, M.J.5
  • 5
    • 0021645224 scopus 로고
    • Reducing motion artifacts and interference in biopotential recording
    • J. G. Webster, "Reducing motion artifacts and interference in biopotential recording," IEEE Transactions on Biomedical Engineering, vol. BME-31, no. 12, pp. 823-826, 1984.
    • (1984) IEEE Transactions on Biomedical Engineering , vol.BME-31 , Issue.12 , pp. 823-826
    • Webster, J.G.1
  • 6
    • 0020641938 scopus 로고
    • Reduction of interference due to common mode voltage in biopotential amplifiers
    • B. B. Winter and J. G. Webster, "Reduction of interference due to common mode voltage in biopotential amplifiers," IEEE Transactions on Biomedical Engineering, vol. BME-30, no. 1, pp. 58-61, 1983.
    • (1983) IEEE Transactions on Biomedical Engineering , vol.BME-30 , Issue.1 , pp. 58-61
    • Winter, B.B.1    Webster, J.G.2
  • 8
    • 80054002023 scopus 로고
    • Interference and motion artifact in biopotentials
    • J. G. Webster, "Interference and motion artifact in biopotentials," Region Six Conference Record, IEEE, pp. 53-64, 1977.
    • (1977) Region Six Conference Record, IEEE , pp. 53-64
    • Webster, J.G.1
  • 9
    • 0004106890 scopus 로고    scopus 로고
    • Medical instrumentation
    • 3rd ed. , J. G. Webster, Ed. John Wiley & Sons, Inc
    • J. G. Webster, Medical Instrumentation, Application and Design, 3rd ed., J. G. Webster, Ed. John Wiley & Sons, Inc, 1998.
    • (1998) Application and Design
    • Webster, J.G.1
  • 14
    • 0025483042 scopus 로고
    • High-quality recording of bioelectric events. Part 1. Interference reduction, theory and practice
    • DOI 10.1007/BF02441961
    • A.C. Metting van Rijn, A. C., Peper, A., and C. A. Grimbergen, "High quality recording of bioelectric events. Part 1: Interference reduction, theory and practice," Medical and Biological Engineering and Computing, vol. 28, pp. 389-397, September 1990. (Pubitemid 20299450)
    • (1990) Medical and Biological Engineering and Computing , vol.28 , Issue.5 , pp. 389-397
    • Metting Van Rijn, A.C.1    Peper, A.2    Grimbergen, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.