메뉴 건너뛰기




Volumn 132, Issue 1, 2013, Pages 77-80

Pneumatic tube transport affects platelet function measured by multiplate electrode aggregometry

Author keywords

Anti platelet treatment; MEA, Multiple electrode aggregometry; Multiplate; Platelet function; PTS, Pneumatic tube transport system

Indexed keywords

ARTICLE; CLINICAL ARTICLE; EQUIPMENT; HEALTH CARE PERSONNEL; HUMAN; INTERMETHOD COMPARISON; MEDICAL PROCEDURES; MULTIPLE ELECTRODE AGGREGOMETRY; PNEUMATIC TUBE TRANSPORT SYSTEM; PRIORITY JOURNAL; THROMBOCYTE FUNCTION; TUBE;

EID: 84881312356     PISSN: 00493848     EISSN: 18792472     Source Type: Journal    
DOI: 10.1016/j.thromres.2013.04.020     Document Type: Article
Times cited : (31)

References (22)
  • 1
    • 80054115369 scopus 로고    scopus 로고
    • Role of Platelet Function Testing in Clinical Practice: Current Concepts and Future Perspectives
    • D. Sibbing, R. Byrne, and A. Kastrati Role of Platelet Function Testing in Clinical Practice: Current Concepts and Future Perspectives Curr Drug Targets 12 2011 1836 1847
    • (2011) Curr Drug Targets , vol.12 , pp. 1836-1847
    • Sibbing, D.1    Byrne, R.2    Kastrati, A.3
  • 4
    • 79959844308 scopus 로고    scopus 로고
    • Platelet function assessed by whole-blood aggregometry in patients undergoing non-cardiac surgery
    • A. Oscarsson, S. Öster, M. Fredrikson, T. Lindahl, and C. Eintrei Platelet function assessed by whole-blood aggregometry in patients undergoing non-cardiac surgery Eur J Anaesthesiol 28 2011 363 369
    • (2011) Eur J Anaesthesiol , vol.28 , pp. 363-369
    • Oscarsson, A.1    Öster, S.2    Fredrikson, M.3    Lindahl, T.4    Eintrei, C.5
  • 5
    • 34248400317 scopus 로고    scopus 로고
    • Variables influencing Multiplate™ whole blood impedance platelet aggregometry and turbidimetric platelet aggregation in healthy individuals
    • DOI 10.1080/09537100600944277, PII 778493029
    • U.T. Seyfert, H. Haubelt, A. Vogt, and P. Hellstern Variables influencing Multiplate(TM) whole blood impedance platelet aggregometry and turbidimetric platelet aggregation in healthy individuals Platelets 18 2007 199 206 (Pubitemid 46744118)
    • (2007) Platelets , vol.18 , Issue.3 , pp. 199-206
    • Seyfert, U.T.1    Haubelt, H.2    Vogt, A.3    Hellstern, P.4
  • 6
    • 84862897074 scopus 로고    scopus 로고
    • A randomized clinical trial comparing point-of-care platelet function assays and bleeding time in healthy subjects treated with aspirin or clopidogrel
    • F. Chen, V. Maridakis, E.A. O'neill, C. Beals, W. Radziszewski, and I. de Lepeleire A randomized clinical trial comparing point-of-care platelet function assays and bleeding time in healthy subjects treated with aspirin or clopidogrel Platelets 23 2012 249 258
    • (2012) Platelets , vol.23 , pp. 249-258
    • Chen, F.1    Maridakis, V.2    O'Neill, E.A.3    Beals, C.4    Radziszewski, W.5    De Lepeleire, I.6
  • 7
    • 53849144983 scopus 로고    scopus 로고
    • Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation
    • O. Wallin, J. Soderberg, K. Grankvist, P.A. Jonsson, and J. Hultdin Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation Clin Chem Lab Med 46 2008 1443 1449
    • (2008) Clin Chem Lab Med , vol.46 , pp. 1443-1449
    • Wallin, O.1    Soderberg, J.2    Grankvist, K.3    Jonsson, P.A.4    Hultdin, J.5
  • 8
    • 0035031559 scopus 로고    scopus 로고
    • Blood gas analysis: POCT versus central laboratory on samples sent by a pneumatic tube system
    • DOI 10.1016/S0009-8981(01)00439-9, PII S0009898101004399
    • Z. Zaman, and M. Demedts Blood gas analysis: POCT versus central laboratory on samples sent by a pneumatic tube system Clin Chim Acta 307 2001 101 106 (Pubitemid 32448910)
    • (2001) Clinica Chimica Acta , vol.307 , Issue.1-2 , pp. 101-106
    • Zaman, Z.1    Demedts, M.2
  • 9
    • 33847000181 scopus 로고    scopus 로고
    • Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers
    • A. Kratz, R.O. Salem, and E.M. Van Cott Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers Arch Pathol Lab Med 131 2007 293 296
    • (2007) Arch Pathol Lab Med , vol.131 , pp. 293-296
    • Kratz, A.1    Salem, R.O.2    Van Cott, E.M.3
  • 11
    • 77954802935 scopus 로고    scopus 로고
    • Validation of a procedure to assess ASA-response in patients with decreased, initial TRAP induced aggregation
    • K. Boeer, M. Reinhöfer, and W. Lösche Validation of a procedure to assess ASA-response in patients with decreased, initial TRAP induced aggregation Platelets 21 2010 314 319
    • (2010) Platelets , vol.21 , pp. 314-319
    • Boeer, K.1    Reinhöfer, M.2    Lösche, W.3
  • 12
    • 70449700159 scopus 로고    scopus 로고
    • Assessment of Platelet Function in Whole Blood by Multiple Electrode Aggregometry: Transport of Samples Using a Pneumatic Tube System
    • S. Braun, N. von Beckerath, J. Ellert, A. Kastrati, A. Schömig, and W. Vogt Assessment of Platelet Function in Whole Blood by Multiple Electrode Aggregometry: Transport of Samples Using a Pneumatic Tube System Am J Clin Pathol 132 2009 802 803
    • (2009) Am J Clin Pathol , vol.132 , pp. 802-803
    • Braun, S.1    Von Beckerath, N.2    Ellert, J.3    Kastrati, A.4    Schömig, A.5    Vogt, W.6
  • 13
    • 13244279451 scopus 로고    scopus 로고
    • The effect of a pneumatic tube transport system on PFA-100™ closure time and whole blood platelet aggregation [5]
    • DOI 10.1111/j.1538-7836.2004.0584e.x
    • A. Dyszkiewicz-Korpanty, R. Quinton, J. Yassine, and R. Sarode The effect of a pneumatic transport system on PFA-100™ closure time and whole blood platelet aggregation J Thromb Haemost 2 2004 354 356 (Pubitemid 40186055)
    • (2004) Journal of Thrombosis and Haemostasis , vol.2 , Issue.2 , pp. 354-356
    • Dyszkiewicz-Korpanty, A.1    Quinton, R.2    Yassine, J.3    Sarode, R.4
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 80054732930 scopus 로고    scopus 로고
    • Optimizing of thienopyridine therapy by multiple electrode platelet aggregometry in clopidogrel low responders undergoing PCI
    • T. Behr, B. Kuch, W. Behr, and W. von Scheidt Optimizing of thienopyridine therapy by multiple electrode platelet aggregometry in clopidogrel low responders undergoing PCI Clin Res Cardiol 10 2011 907 914
    • (2011) Clin Res Cardiol , vol.10 , pp. 907-914
    • Behr, T.1    Kuch, B.2    Behr, W.3    Von Scheidt, W.4
  • 16
    • 84869488610 scopus 로고    scopus 로고
    • Aspirin Resistance: Current Status and Role of Tailored Therapy
    • J. Grinstein, and C.P. Cannon Aspirin Resistance: Current Status and Role of Tailored Therapy Clin Cardiol 11 2012 673 680
    • (2012) Clin Cardiol , vol.11 , pp. 673-680
    • Grinstein, J.1    Cannon, C.P.2
  • 17
    • 0029117443 scopus 로고
    • Physical and chemical effects of red cells in the shear-induced aggregation of human platelets
    • H. Goldsmith, D. Bell, S. Braovac, A. Steinberg, and F. McIntosh Physical and chemical effects of red cells in the shear-induced aggregation of human platelets Biophys J 69 1995 1584 1595
    • (1995) Biophys J , vol.69 , pp. 1584-1595
    • Goldsmith, H.1    Bell, D.2    Braovac, S.3    Steinberg, A.4    McIntosh, F.5
  • 18
    • 0023148936 scopus 로고
    • Shear stress activation of platelets with subsequent refractoriness
    • DOI 10.1016/0049-3848(87)90254-4
    • I. Aursnes, J. Sundal, and T. Nome Shear stress activation of platelets with subsequent refractoriness Thromb Res 45 1987 29 37 (Pubitemid 17006303)
    • (1987) Thrombosis Research , vol.45 , Issue.1 , pp. 29-37
    • Aursnes, I.1    Sundal, J.2    Nome, T.3
  • 19
    • 84860463955 scopus 로고    scopus 로고
    • Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis
    • A.K. Tiwari, P. Pandey, S. Dixit, and V. Raina Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis Clin Chem Lab Med 50 2011 471 474
    • (2011) Clin Chem Lab Med , vol.50 , pp. 471-474
    • Tiwari, A.K.1    Pandey, P.2    Dixit, S.3    Raina, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.