메뉴 건너뛰기




Volumn 8, Issue , 2013, Pages 2821-2833

Physicochemical characterization of a novel graphene-based magnetic resonance imaging contrast agent

Author keywords

Contrast agent; Dextran; Graphene; Magnetic resonance imaging; Manganese; Physicochemical properties; Preclinical; Relaxivity

Indexed keywords

DEIONIZED WATER; DEXTRAN; GADOBENATE DIMEGLUMINE; GADODIAMIDE; GADOLINIUM; GADOLINIUM PENTETATE MEGLUMINE; GADOTERIDOL; GADOVERSETAMIDE; GRAPHENE OXIDE; MANGAFODIPIR; MANGANESE; MANGANESE ION INTERCALATED GRAPHENE OXIDE NANOPLATELET FUNCTIONALIZED WITH DEXTRAN; MANNITOL; MULTI HANCE; NANOMATERIAL; NUCLEAR MAGNETIC RESONANCE IMAGING AGENT; UNCLASSIFIED DRUG; WATER;

EID: 84881304897     PISSN: 11769114     EISSN: 11782013     Source Type: Journal    
DOI: 10.2147/IJN.S47062     Document Type: Article
Times cited : (68)

References (49)
  • 1
    • 45849099836 scopus 로고    scopus 로고
    • Gadofullerenes and gadonanotubes: A new paradigm for high-performance magnetic resonance imaging contrast agent probes
    • Sitharaman B, Wilson LJ. Gadofullerenes and gadonanotubes: a new paradigm for high-performance magnetic resonance imaging contrast agent probes. J Biomed Nanotechnol. 2007;3(4):342-352.
    • (2007) J Biomed Nanotechnol , vol.3 , Issue.4 , pp. 342-352
    • Sitharaman, B.1    Wilson, L.J.2
  • 3
    • 78149405873 scopus 로고    scopus 로고
    • Geometrical confinement of gadolinium-based contrast agents in nanoporous particles enhances T1 contrast
    • Ananta JS, Godin B, Sethi R, et al. Geometrical confinement of gadolinium-based contrast agents in nanoporous particles enhances T1 contrast. Nat Nanotechnol. 2010;5(11):815-821.
    • (2010) Nat Nanotechnol , vol.5 , Issue.11 , pp. 815-821
    • Ananta, J.S.1    Godin, B.2    Sethi, R.3
  • 4
    • 43049114497 scopus 로고    scopus 로고
    • Nephrogenic systemic fibrosis associated with gadolinium based contrast agents: A summary of the medical literature reporting
    • Broome DR. Nephrogenic systemic fibrosis associated with gadolinium based contrast agents: a summary of the medical literature reporting. Eur J Radiol. 2008;66(2):230-234.
    • (2008) Eur J Radiol , vol.66 , Issue.2 , pp. 230-234
    • Broome, D.R.1
  • 5
    • 84881295324 scopus 로고    scopus 로고
    • Bayer HealthCare Pharmaceuticals Inc, Bracco Diagnostics Inc, GE Healthcare, Mallinkrodit Inc Important Drug Warning for Gadoliniumbased Contrast Agents [letter to healthcare professionals]. Bayer HealthCare Pharmaceuticals Inc, Bracco Diagnostics Inc, GE Healthcare, Mallinkrodit Inc, Available from:, Accessed June 18, 2013
    • Bayer HealthCare Pharmaceuticals Inc, Bracco Diagnostics Inc, GE Healthcare, Mallinkrodit Inc Important Drug Warning for Gadoliniumbased Contrast Agents [letter to healthcare professionals]. Bayer HealthCare Pharmaceuticals Inc, Bracco Diagnostics Inc, GE Healthcare, Mallinkrodit Inc; 2007. Available from: http://www.fda.gov/downloads/safety/medwatch/safetyinformation/safetyalertsforhumanmedicalproducts/ucm154532.pdf. Accessed June 18, 2013.
    • (2007)
  • 6
    • 79952586310 scopus 로고    scopus 로고
    • Graphene in biomedicine: Opportunities and challenges
    • Feng L, Liu Z. Graphene in biomedicine: opportunities and challenges. Nanomedicine (Lond). 2011;6(2):317-324.
    • (2011) Nanomedicine (Lond) , vol.6 , Issue.2 , pp. 317-324
    • Feng, L.1    Liu, Z.2
  • 7
    • 84862023932 scopus 로고    scopus 로고
    • Physicochemical characterization, and relaxometry studies of micrographite oxide, graphene nanoplatelets, and nanoribbons
    • Paratala BS, Jacobson BD, Kanakia S, Francis LD, Sitharaman B. Physicochemical characterization, and relaxometry studies of micrographite oxide, graphene nanoplatelets, and nanoribbons. PLoS One. 2012;7(6):e38185.
    • (2012) PLoS One , vol.7 , Issue.6
    • Paratala, B.S.1    Jacobson, B.D.2    Kanakia, S.3    Francis, L.D.4    Sitharaman, B.5
  • 8
    • 27544442176 scopus 로고    scopus 로고
    • Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    • Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ. Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol. 2005;40(11):715-724.
    • (2005) Invest Radiol , vol.40 , Issue.11 , pp. 715-724
    • Rohrer, M.1    Bauer, H.2    Mintorovitch, J.3    Requardt, M.4    Weinmann, H.J.5
  • 9
    • 0028892584 scopus 로고
    • Pre-clinical evaluation of gadobutrol: A new, neutral, extracellular contrast agent for magnetic resonance imaging
    • Vogler H, Platzek J, Schuhmann-Giampieri G, et al. Pre-clinical evaluation of gadobutrol: a new, neutral, extracellular contrast agent for magnetic resonance imaging. Eur J Radiol. 1995;21(1):1-10.
    • (1995) Eur J Radiol , vol.21 , Issue.1 , pp. 1-10
    • Vogler, H.1    Platzek, J.2    Schuhmann-Giampieri, G.3
  • 10
    • 84881277668 scopus 로고    scopus 로고
    • ICH, Geneva: International Conference on Harmonisation, Available from:, Accessed July 15, 2013
    • ICH. Safety pharmacology studies for human pharmaceuticals. Geneva: International Conference on Harmonisation; 2000. Available from: http://www.ich.org/fileadmin/Public_Web_Site/ICH_Products/Guidelines/Safety/S7A/Step4/S7A_Guideline.pdf. Accessed July 15, 2013.
    • (2000) Safety Pharmacology Studies For Human Pharmaceuticals
  • 12
    • 0003479926 scopus 로고    scopus 로고
    • OECD, Paris: Organisation for Economic Co-operation and Development, Available from:, Accessed July 15, 2013
    • OECD. OECD guidelines for the testing of chemicals. Paris: Organisation for Economic Co-operation and Development; 2000. Available from: http://www.oecd.org/chemicalsafety/testing/2731134.pdf. Accessed July 15, 2013.
    • (2000) OECD Guidelines For the Testing of Chemicals
  • 13
    • 0033852026 scopus 로고    scopus 로고
    • Safety of approved MR contrast media for intravenous injection
    • Runge VM. Safety of approved MR contrast media for intravenous injection. J Magn Reson Imaging. 2000;12(2):205-213.
    • (2000) J Magn Reson Imaging , vol.12 , Issue.2 , pp. 205-213
    • Runge, V.M.1
  • 14
    • 79960019416 scopus 로고    scopus 로고
    • In vitro and in vivo behaviors of dextran functionalized graphene
    • Zhang S, Yang K, Feng L, Liu Z. In vitro and in vivo behaviors of dextran functionalized graphene. Carbon. 2011;49(12):4040-4049.
    • (2011) Carbon , vol.49 , Issue.12 , pp. 4040-4049
    • Zhang, S.1    Yang, K.2    Feng, L.3    Liu, Z.4
  • 16
    • 84881302225 scopus 로고    scopus 로고
    • Feridex IV (ferumoxides injectable solution) [package insert]. Wayne, NJ: Bayer Healthcare Pharmaceuticals Inc, Available from:, Accessed June 18, 2013
    • Feridex IV (ferumoxides injectable solution) [package insert]. Wayne, NJ: Bayer Healthcare Pharmaceuticals Inc; 2007. Available from: http://www.amagpharma.com/documents/products/pdfs/feridex_insert.pdf. Accessed June 18, 2013.
    • (2007)
  • 17
    • 33748776267 scopus 로고    scopus 로고
    • Nonfouling characteristics of dextrancontaining surfaces
    • Martwiset S, Koh AE, Chen W. Nonfouling characteristics of dextrancontaining surfaces. Langmuir. 2006;22(19):8192-8196.
    • (2006) Langmuir , vol.22 , Issue.19 , pp. 8192-8196
    • Martwiset, S.1    Koh, A.E.2    Chen, W.3
  • 18
    • 34249742469 scopus 로고    scopus 로고
    • Synthesis of graphene-based nanosheets via chemical reduction of exfoliated graphite oxide
    • Stankovich S, Dikin DA, Piner RD, et al. Synthesis of graphene-based nanosheets via chemical reduction of exfoliated graphite oxide. Carbon. 2007;45(7):1558-1565.
    • (2007) Carbon , vol.45 , Issue.7 , pp. 1558-1565
    • Stankovich, S.1    Dikin, D.A.2    Piner, R.D.3
  • 19
    • 30144432589 scopus 로고    scopus 로고
    • One-step synthesis of dextran-based stable nanoparticles assisted by self-assembly
    • Tang M, Dou H, Sun K. One-step synthesis of dextran-based stable nanoparticles assisted by self-assembly. Polymer. 2006;47(2):728-734.
    • (2006) Polymer , vol.47 , Issue.2 , pp. 728-734
    • Tang, M.1    Dou, H.2    Sun, K.3
  • 20
    • 0343474942 scopus 로고
    • Physical stability of suspensions
    • Zatz JL. Physical stability of suspensions. J Soc Cosmet Chem. 1985;36(6):393-411.
    • (1985) J Soc Cosmet Chem , vol.36 , Issue.6 , pp. 393-411
    • Zatz, J.L.1
  • 21
    • 0031300548 scopus 로고    scopus 로고
    • The ProHance story: The making of a novel MRI contrast agent
    • Tweedle MF. The ProHance story: the making of a novel MRI contrast agent. Eur Radiol. 1997;7 Suppl 5:225-230.
    • (1997) Eur Radiol , vol.7 , Issue.SUPPL. 5 , pp. 225-230
    • Tweedle, M.F.1
  • 23
    • 74949085018 scopus 로고    scopus 로고
    • Water-soluble graphene covalently functionalized by biocompatible poly-L-lysine
    • Shan C, Yang H, Han D, Zhang Q, Ivaska A, Niu L. Water-soluble graphene covalently functionalized by biocompatible poly-L-lysine. Langmuir. 2009;25(20):12030-12033.
    • (2009) Langmuir , vol.25 , Issue.20 , pp. 12030-12033
    • Shan, C.1    Yang, H.2    Han, D.3    Zhang, Q.4    Ivaska, A.5    Niu, L.6
  • 24
    • 50249123111 scopus 로고    scopus 로고
    • PEGylated nanographene oxide for delivery of water-insoluble cancer drugs
    • Liu Z, Robinson JT, Sun X, Dai H. PEGylated nanographene oxide for delivery of water-insoluble cancer drugs. J Am Chem Soc. 2008;130(33): 10876-10877.
    • (2008) J Am Chem Soc , vol.130 , Issue.33 , pp. 10876-10877
    • Liu, Z.1    Robinson, J.T.2    Sun, X.3    Dai, H.4
  • 25
    • 79952820824 scopus 로고    scopus 로고
    • Biocompatible reduced graphene oxide prepared by using dextran as a multifunctional reducing agent
    • Kim YK, Kim MH, Min DH. Biocompatible reduced graphene oxide prepared by using dextran as a multifunctional reducing agent. Chem Commun (Camb). 2011;47(11):3195-3197.
    • (2011) Chem Commun (Camb) , vol.47 , Issue.11 , pp. 3195-3197
    • Kim, Y.K.1    Kim, M.H.2    Min, D.H.3
  • 26
    • 0030013470 scopus 로고    scopus 로고
    • Are low osmolality contrast media less nephrotoxic?
    • Deray G, Jacobs C. Are low osmolality contrast media less nephrotoxic? Nephrol Dial Transplant. 1996;11(6):930-931.
    • (1996) Nephrol Dial Transplant , vol.11 , Issue.6 , pp. 930-931
    • Deray, G.1    Jacobs, C.2
  • 27
    • 84860654423 scopus 로고    scopus 로고
    • American Society of Health-System Pharmacists, Bethesda, MD, Contrast Media and Medication Management Standard Resource Center
    • American Society of Health-System Pharmacists. Quick Guide to Contrast Media. Bethesda, MD: Contrast Media and Medication Management Standard Resource Center; 2010.
    • (2010) Quick Guide to Contrast Media
  • 28
    • 0003149983 scopus 로고    scopus 로고
    • Haemodynamic and rheological effects of contrast media: The role of viscosity and osmolality
    • Pugh ND. Haemodynamic and rheological effects of contrast media: the role of viscosity and osmolality. Eur Radiol. 1996;6 Suppl 2: S13-S15.
    • (1996) Eur Radiol , vol.6 , Issue.SUPPL. 2
    • Pugh, N.D.1
  • 30
    • 0036081889 scopus 로고    scopus 로고
    • Effects of two dimeric iodinated contrast media on renal medullary blood perfusion and oxygenation in dogs
    • Lancelot E, Idée JM, Laclédère C, Santus R, Corot C. Effects of two dimeric iodinated contrast media on renal medullary blood perfusion and oxygenation in dogs. Invest Radiol. 2002;37(7):368-375.
    • (2002) Invest Radiol , vol.37 , Issue.7 , pp. 368-375
    • Lancelot, E.1    Idée, J.M.2    Laclédère, C.3    Santus, R.4    Corot, C.5
  • 31
    • 67651098771 scopus 로고    scopus 로고
    • Protein-targeted gadolinium-based magnetic resonance imaging (MRI) contrast agents: Design and mechanism of action
    • Caravan P. Protein-targeted gadolinium-based magnetic resonance imaging (MRI) contrast agents: design and mechanism of action. Acc Chem Res. 2009;42(7):851-862.
    • (2009) Acc Chem Res , vol.42 , Issue.7 , pp. 851-862
    • Caravan, P.1
  • 32
    • 79955007487 scopus 로고    scopus 로고
    • Development and validation of a higher-throughput equilibrium dialysis assay for plasma protein binding
    • van Liempd S, Morrison D, Sysmans L, Nelis P, Mortishire-Smith R. Development and validation of a higher-throughput equilibrium dialysis assay for plasma protein binding. J Lab Autom. 2011;16(1):56-67.
    • (2011) J Lab Autom , vol.16 , Issue.1 , pp. 56-67
    • van Liempd, S.1    Morrison, D.2    Sysmans, L.3    Nelis, P.4    Mortishire-Smith, R.5
  • 33
    • 79959551151 scopus 로고    scopus 로고
    • Can we accurately quantify nanoparticle associated proteins when constructing high-affinity MRI molecular imaging probes?
    • Rimkus G, Bremer-Streck S, Grüttner C, Kaiser WA, Hilger I. Can we accurately quantify nanoparticle associated proteins when constructing high-affinity MRI molecular imaging probes? Contrast Media Mol Imaging. 2011;6(3):119-125.
    • (2011) Contrast Media Mol Imaging , vol.6 , Issue.3 , pp. 119-125
    • Rimkus, G.1    Bremer-Streck, S.2    Grüttner, C.3    Kaiser, W.A.4    Hilger, I.5
  • 34
    • 0025250753 scopus 로고
    • The nutritional relationships of manganese
    • Watts DL. The nutritional relationships of manganese. J Orthomol Med. 1990;5(4):219-222.
    • (1990) J Orthomol Med , vol.5 , Issue.4 , pp. 219-222
    • Watts, D.L.1
  • 35
    • 0018584053 scopus 로고    scopus 로고
    • Serum levels of selenium, calcium, copper magnesium, manganese and zinc in various human diseases
    • Sullivan JF, Blotcky AJ, Jetton MM, Hahn HK, Burch RE. Serum levels of selenium, calcium, copper magnesium, manganese and zinc in various human diseases. J Nutr. 109(8):1432-1437.
    • J Nutr , vol.109 , Issue.8 , pp. 1432-1437
    • Sullivan, J.F.1    Blotcky, A.J.2    Jetton, M.M.3    Hahn, H.K.4    Burch, R.E.5
  • 36
    • 0025895433 scopus 로고
    • Manganese neurotoxicity: Cellular effects and blood-brain barrier transport
    • Aschner M, Aschner JL. Manganese neurotoxicity: cellular effects and blood-brain barrier transport. Neurosci Biobehav Rev. 1991;15(3): 333-340.
    • (1991) Neurosci Biobehav Rev , vol.15 , Issue.3 , pp. 333-340
    • Aschner, M.1    Aschner, J.L.2
  • 37
    • 0036885886 scopus 로고    scopus 로고
    • Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR). Dialysis and contrast media
    • Morcos SK, Thomsen HS, Webb JA Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR). Dialysis and contrast media. Eur Radiol. 2002;12(12):3026-3030.
    • (2002) Eur Radiol , vol.12 , Issue.12 , pp. 3026-3030
    • Morcos, S.K.1    Thomsen, H.S.2    Webb, J.A.3
  • 39
    • 37549005609 scopus 로고    scopus 로고
    • Allergic-like breakthrough reactions to gadolinium contrast agents after corticosteroid and antihistamine premedication
    • Dillman JR, Ellis JH, Cohan RH, Strouse PJ, Jan SC. Allergic-like breakthrough reactions to gadolinium contrast agents after corticosteroid and antihistamine premedication. AJR Am J Oroentgenol. 2008;190(1): 187-190.
    • (2008) AJR Am J Oroentgenol , vol.190 , Issue.1 , pp. 187-190
    • Dillman, J.R.1    Ellis, J.H.2    Cohan, R.H.3    Strouse, P.J.4    Jan, S.C.5
  • 40
    • 59449094474 scopus 로고    scopus 로고
    • Influence of magnetic resonance contrast media on the activity of histamine inactivating enzymes
    • Kuefner MA, Feurle J, Uder M, Bautz W, Schwelberger HG. Influence of magnetic resonance contrast media on the activity of histamine inactivating enzymes. Acad Radiol. 2009;16(3):358-362.
    • (2009) Acad Radiol , vol.16 , Issue.3 , pp. 358-362
    • Kuefner, M.A.1    Feurle, J.2    Uder, M.3    Bautz, W.4    Schwelberger, H.G.5
  • 41
    • 84881297987 scopus 로고    scopus 로고
    • ProHance® (gadoteridol) injection, solution [product label]. Princeton, NJ: Bracco Diagnostics Inc; nd. Available from:, Accessed June 18, 2013
    • ProHance® (gadoteridol) injection, solution [product label]. Princeton, NJ: Bracco Diagnostics Inc; nd. Available from: http://dailymed.nlm.nih.gov/dailymed/lookup.cfm?setid=778aee03-07d4c-481a-be8a-a75db0702f5a. Accessed June 18, 2013.
  • 42
    • 84881295186 scopus 로고    scopus 로고
    • MultiHance - gadobenate dimeglumine injection, solution [highlights of prescribing information]. Princeton, NJ: Bracco Diagnostics Inc; nd. Available from:, Accessed June 18, 2013
    • MultiHance - gadobenate dimeglumine injection, solution [highlights of prescribing information]. Princeton, NJ: Bracco Diagnostics Inc; nd. Available from: http://dailymed.nlm.nih.gov/dailymed/lookup.cfm?setid=e56fd303-309e0c-490b-8f31-64fc267b4df5. Accessed June 18, 2013.
  • 43
    • 84881309025 scopus 로고    scopus 로고
    • Magnevist® (brand of gadopentetate dimeglumine) [package insert]. Wayne, NJ: Bayer HealthCare Pharmaceuticals Inc, Available from:, Accessed June 18, 2013
    • Magnevist® (brand of gadopentetate dimeglumine) [package insert]. Wayne, NJ: Bayer HealthCare Pharmaceuticals Inc; 2011. Available from: http://labeling.bayerhealthcare.com/html/products/pi/Magnevist_PI.pdf. Accessed June 18, 2013.
    • (2011)
  • 44
    • 84881303045 scopus 로고    scopus 로고
    • Teslascan data sheet [webpage on the Internet]. Portland: RxList Inc., Available from:, Accessed July 15, 2013
    • Teslascan data sheet [webpage on the Internet]. Portland: RxList Inc.; 2009. Available from: http://www.rxlist.com/teslascan-drug.htm. Accessed July 15, 2013.
    • (2009)
  • 45
    • 84881301761 scopus 로고    scopus 로고
    • Optimark [package insert]. Hazelwood, MO: Mallinckrodt; nd. Available from:, Accessed June 18, 2013
    • Optimark [package insert]. Hazelwood, MO: Mallinckrodt; nd. Available from: http://www.mallinckrodt.com/webforms/threecolumn.aspx?id=497. Accessed June 18, 2013.
  • 46
    • 84881291243 scopus 로고    scopus 로고
    • Omniscan™ (gadodiamide) injection [product label]. Princeton, NJ: GE Healthcare, Accessed July 15, 2013
    • Omniscan™ (gadodiamide) injection [product label]. Princeton, NJ: GE Healthcare; 2011. http://dailymed.nlm.nih.gov/dailymed/lookup.cfm?setid=1e9a37e2-f28a-4373-bf0f-3e9b60f42d8a. Accessed July 15, 2013.
    • (2011)
  • 47
    • 0041472781 scopus 로고    scopus 로고
    • Dendrimer-based macromolecular MRI contrast agents: Characteristics and application
    • Kobayashi H, Brechbiel MW. Dendrimer-based macromolecular MRI contrast agents: characteristics and application. Mol Imaging. 2003;2(1):1-10.
    • (2003) Mol Imaging , vol.2 , Issue.1 , pp. 1-10
    • Kobayashi, H.1    Brechbiel, M.W.2
  • 48
    • 84859589244 scopus 로고    scopus 로고
    • Multimodal imaging guided photothermal therapy using functionalized graphene nanosheets anchored with magnetic nanoparticles
    • Yang K, Hu L, Ma X, et al. Multimodal imaging guided photothermal therapy using functionalized graphene nanosheets anchored with magnetic nanoparticles. Adv Mater. 2012;24(14):1868-1872.
    • (2012) Adv Mater , vol.24 , Issue.14 , pp. 1868-1872
    • Yang, K.1    Hu, L.2    Ma, X.3
  • 49
    • 34548809094 scopus 로고    scopus 로고
    • Gadonanotubes as new high-performance MRI contrast agents
    • Sitharaman B, Wilson LJ. Gadonanotubes as new high-performance MRI contrast agents. Int J Nanomedicine. 2006;1(3):291-295.
    • (2006) Int J Nanomedicine , vol.1 , Issue.3 , pp. 291-295
    • Sitharaman, B.1    Wilson, L.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.