메뉴 건너뛰기




Volumn 43, Issue 5, 2013, Pages 396-402

FDG-PET in prosthetic graft infections

Author keywords

[No Author keywords available]

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 84881114213     PISSN: 00012998     EISSN: 15584623     Source Type: Journal    
DOI: 10.1053/j.semnuclmed.2013.04.004     Document Type: Article
Times cited : (53)

References (48)
  • 1
    • 77955467858 scopus 로고    scopus 로고
    • Conservative treatment of vascular prosthetic graft infection is associated with high mortality
    • B.R. Saleem, R. Meerwaldt, and I.F. Tielliu Conservative treatment of vascular prosthetic graft infection is associated with high mortality Am J Surg 200 1 2010 47 52
    • (2010) Am J Surg , vol.200 , Issue.1 , pp. 47-52
    • Saleem, B.R.1    Meerwaldt, R.2    Tielliu, I.F.3
  • 2
    • 34250853384 scopus 로고    scopus 로고
    • Prevention of infection in peripheral arterial reconstruction: A systematic review and meta-analysis
    • A.H. Stewart, P.S. Eyers, and J.J. Earnshaw Prevention of infection in peripheral arterial reconstruction: A systematic review and meta-analysis J Vasc Surg 46 1 2007 148 155
    • (2007) J Vasc Surg , vol.46 , Issue.1 , pp. 148-155
    • Stewart, A.H.1    Eyers, P.S.2    Earnshaw, J.J.3
  • 3
    • 0033964255 scopus 로고    scopus 로고
    • Management of patients with prosthetic vascular graft infection
    • J.M. Seeger Management of patients with prosthetic vascular graft infection Am Surg 66 2 2000 166 177
    • (2000) Am Surg , vol.66 , Issue.2 , pp. 166-177
    • Seeger, J.M.1
  • 4
    • 33745489940 scopus 로고    scopus 로고
    • Prosthetic vascular graft infection: A risk factor analysis using a case-control study
    • V.S. Antonios, A.A. Noel, and J.M. Steckelberg Prosthetic vascular graft infection: A risk factor analysis using a case-control study J Infect 53 1 2006 49 55
    • (2006) J Infect , vol.53 , Issue.1 , pp. 49-55
    • Antonios, V.S.1    Noel, A.A.2    Steckelberg, J.M.3
  • 6
    • 0031048293 scopus 로고    scopus 로고
    • Graft-related complications after abdominal aortic aneurysm repair: Reassurance from a 36-year population-based experience
    • [discussion 285-6]
    • J.W. Hallett Jr Graft-related complications after abdominal aortic aneurysm repair: Reassurance from a 36-year population-based experience J Vasc Surg 25 2 1997 277 284 [discussion 285-6]
    • (1997) J Vasc Surg , vol.25 , Issue.2 , pp. 277-284
    • Hallett Jr., J.W.1
  • 7
    • 84877720599 scopus 로고    scopus 로고
    • Vascular graft infections
    • B. Hasse Vascular graft infections Swiss Med Wkly 143 2013 w13754
    • (2013) Swiss Med Wkly , vol.143 , pp. 13754
    • Hasse, B.1
  • 8
    • 33845922098 scopus 로고    scopus 로고
    • Does the timing of reoperation influence the risk of graft infection?
    • S. Kolakowski Jr, M.J. Dougherty, and K.D. Calligaro Does the timing of reoperation influence the risk of graft infection? J Vasc Surg 45 1 2007 60 64
    • (2007) J Vasc Surg , vol.45 , Issue.1 , pp. 60-64
    • Kolakowski Jr., S.1    Dougherty, M.J.2    Calligaro, K.D.3
  • 9
    • 0026662763 scopus 로고
    • Are gram-negative bacteria a contraindication to selective preservation of infected prosthetic arterial grafts?
    • [discussion 345-6]
    • K.D. Calligaro Are gram-negative bacteria a contraindication to selective preservation of infected prosthetic arterial grafts? J Vasc Surg 16 3 1992 337 345 [discussion 345-6]
    • (1992) J Vasc Surg , vol.16 , Issue.3 , pp. 337-345
    • Calligaro, K.D.1
  • 10
    • 1842483412 scopus 로고    scopus 로고
    • Treatment of infections associated with surgical implants
    • R.O. Darouiche Treatment of infections associated with surgical implants N Engl J Med 350 14 2004 1422 1429
    • (2004) N Engl J Med , vol.350 , Issue.14 , pp. 1422-1429
    • Darouiche, R.O.1
  • 11
    • 0028199941 scopus 로고
    • Prosthetic graft infection
    • D.F. Bandyk, and G.E. Esses Prosthetic graft infection Surg Clin North Am 74 3 1994 571 590
    • (1994) Surg Clin North Am , vol.74 , Issue.3 , pp. 571-590
    • Bandyk, D.F.1    Esses, G.E.2
  • 12
    • 33746232895 scopus 로고    scopus 로고
    • Infection in prosthetic vascular grafts
    • R.B. Ratherford, Saunders Philadelphia, PA
    • D.F. Bandyk, and M.R. Back Infection in prosthetic vascular grafts R.B. Ratherford, Vascular Surgery 2005 Saunders Philadelphia, PA 875 894
    • (2005) Vascular Surgery , pp. 875-894
    • Bandyk, D.F.1    Back, M.R.2
  • 13
    • 0016193711 scopus 로고
    • Infection in vascular prostheses. Clinical manifestations and surgical management
    • J. Goldstone, and W.S. Moore Infection in vascular prostheses. Clinical manifestations and surgical management Am J Surg 128 2 1974 225 233
    • (1974) Am J Surg , vol.128 , Issue.2 , pp. 225-233
    • Goldstone, J.1    Moore, W.S.2
  • 14
    • 0034220406 scopus 로고    scopus 로고
    • Aortic prosthetic graft infections: Radiologic manifestations and implications for management
    • D.F. Orton, R.F. LeVeen, and J.A. Saigh Aortic prosthetic graft infections: Radiologic manifestations and implications for management Radiographics 20 4 2000 977 993
    • (2000) Radiographics , vol.20 , Issue.4 , pp. 977-993
    • Orton, D.F.1    Leveen, R.F.2    Saigh, J.A.3
  • 15
    • 38649117932 scopus 로고    scopus 로고
    • The incidence and factors associated with graft infection after aortic aneurysm repair
    • T.R. Vogel, R. Symons, and D.R. Flum The incidence and factors associated with graft infection after aortic aneurysm repair J Vasc Surg 47 2 2008 264 269
    • (2008) J Vasc Surg , vol.47 , Issue.2 , pp. 264-269
    • Vogel, T.R.1    Symons, R.2    Flum, D.R.3
  • 16
    • 79251596731 scopus 로고    scopus 로고
    • Molecular diagnosis of nonaneurysmal infectious aortitis
    • S. Kanemitsu, T. Shimono, and A. Nakamura Molecular diagnosis of nonaneurysmal infectious aortitis J Vasc Surg 53 2 2011 472 474
    • (2011) J Vasc Surg , vol.53 , Issue.2 , pp. 472-474
    • Kanemitsu, S.1    Shimono, T.2    Nakamura, A.3
  • 17
    • 58849104094 scopus 로고    scopus 로고
    • Imaging of vascular graft infection
    • I.P.C. Murray, P.J. Ell, Churchill Livingstone Edinburgh
    • J.E. Seabold Imaging of vascular graft infection I.P.C. Murray, P.J. Ell, Nuclear Medicine in Clinical Diagnosis and Treatment 1999 Churchill Livingstone Edinburgh
    • (1999) Nuclear Medicine in Clinical Diagnosis and Treatment
    • Seabold, J.E.1
  • 18
    • 0032915562 scopus 로고    scopus 로고
    • Imaging techniques for evaluation of postoperative orthopedic infections
    • J.E. Seabold, and J.V. Nepola Imaging techniques for evaluation of postoperative orthopedic infections Q J Nucl Med 43 1 1999 21 28
    • (1999) Q J Nucl Med , vol.43 , Issue.1 , pp. 21-28
    • Seabold, J.E.1    Nepola, J.V.2
  • 19
    • 34548264125 scopus 로고    scopus 로고
    • Detection of abdominal aortic graft infection: Comparison of magnetic resonance imaging and indium-labeled white blood cell scanning
    • S. Shahidi, A. Eskil, and E. Lundorf Detection of abdominal aortic graft infection: Comparison of magnetic resonance imaging and indium-labeled white blood cell scanning Ann Vasc Surg 21 5 2007 586 592
    • (2007) Ann Vasc Surg , vol.21 , Issue.5 , pp. 586-592
    • Shahidi, S.1    Eskil, A.2    Lundorf, E.3
  • 20
    • 0141669363 scopus 로고    scopus 로고
    • Clinical performance of PET/CT in evaluation of cancer: Additional value for diagnostic imaging and patient management
    • R. Bar-Shalom, N. Yefremov, and L. Guralnik Clinical performance of PET/CT in evaluation of cancer: Additional value for diagnostic imaging and patient management J Nucl Med 44 8 2003 1200 1209
    • (2003) J Nucl Med , vol.44 , Issue.8 , pp. 1200-1209
    • Bar-Shalom, R.1    Yefremov, N.2    Guralnik, L.3
  • 21
    • 0038148743 scopus 로고    scopus 로고
    • SPECT/CT in tumor imaging: Technical aspects and clinical applications
    • Z. Keidar, O. Israel, and Y. Krausz SPECT/CT in tumor imaging: Technical aspects and clinical applications Semin Nucl Med 33 3 2003 205 218
    • (2003) Semin Nucl Med , vol.33 , Issue.3 , pp. 205-218
    • Keidar, Z.1    Israel, O.2    Krausz, Y.3
  • 22
    • 78650507686 scopus 로고    scopus 로고
    • In situ rifampin-soaked grafts with omental coverage and antibiotic suppression are durable with low reinfection rates in patients with aortic graft enteric erosion or fistula
    • 107 e1-7 [discussion 106-7]
    • G.S. Oderich, T.C. Bower, and J. Hofer In situ rifampin-soaked grafts with omental coverage and antibiotic suppression are durable with low reinfection rates in patients with aortic graft enteric erosion or fistula J Vasc Surg 53 1 2011 99-106, 107 e1-7 [discussion 106-7]
    • (2011) J Vasc Surg , vol.53 , Issue.1 , pp. 99-106
    • Oderich, G.S.1    Bower, T.C.2    Hofer, J.3
  • 23
    • 84860637956 scopus 로고    scopus 로고
    • Aortic graft infections: Current perspectives. Introduction
    • P. Berger, and F.L. Moll Aortic graft infections: Current perspectives. Introduction Semin Vasc Surg 24 4 2011 181
    • (2011) Semin Vasc Surg , vol.24 , Issue.4 , pp. 181
    • Berger, P.1    Moll, F.L.2
  • 24
  • 25
    • 40449090476 scopus 로고    scopus 로고
    • Imaging of infectious diseases using [(18)F]fluorodeoxyglucose PET
    • C.P. Bleeker-Rovers, F.J. Vos, and H.M. Corstens Imaging of infectious diseases using [(18)F]fluorodeoxyglucose PET Q J Nucl Med Mol Imaging 52 1 2008 17 29
    • (2008) Q J Nucl Med Mol Imaging , vol.52 , Issue.1 , pp. 17-29
    • Bleeker-Rovers, C.P.1    Vos, F.J.2    Corstens, H.M.3
  • 26
    • 0036245331 scopus 로고    scopus 로고
    • Promising role of 18-F-fluoro-D-deoxyglucose positron emission tomography in clinical infectious diseases
    • F. De Winter, D. Vogelaers, and F. Gemmel Promising role of 18-F-fluoro-D-deoxyglucose positron emission tomography in clinical infectious diseases Eur J Clin Microbiol Infect Dis 21 4 2002 247 257
    • (2002) Eur J Clin Microbiol Infect Dis , vol.21 , Issue.4 , pp. 247-257
    • De Winter, F.1    Vogelaers, D.2    Gemmel, F.3
  • 27
    • 0034945682 scopus 로고    scopus 로고
    • New concepts in infection/inflammation imaging
    • H.J. Rennen, F.H. Corstens, and W.J. Oyen New concepts in infection/inflammation imaging Q J Nucl Med 45 2 2001 167 173
    • (2001) Q J Nucl Med , vol.45 , Issue.2 , pp. 167-173
    • Rennen, H.J.1    Corstens, F.H.2    Oyen, W.J.3
  • 28
    • 33846140451 scopus 로고    scopus 로고
    • Masked prosthetic graft to sigmoid colon fistula diagnosed by 18-fluorodeoxyglucose positron emission tomography
    • T. Tsunekawa, H. Ogino, and K. Minatoya Masked prosthetic graft to sigmoid colon fistula diagnosed by 18-fluorodeoxyglucose positron emission tomography Eur J Vasc Endovasc Surg 33 2 2007 187 189
    • (2007) Eur J Vasc Endovasc Surg , vol.33 , Issue.2 , pp. 187-189
    • Tsunekawa, T.1    Ogino, H.2    Minatoya, K.3
  • 29
    • 0141746238 scopus 로고    scopus 로고
    • 18-Fluorodeoxyglucose positron emission tomography as a novel imaging tool for the diagnosis of aortoenteric fistula and aortic graft infection - A case report
    • A.S. Krupnick, J.V. Lombardi, and F.H. Engels 18-Fluorodeoxyglucose positron emission tomography as a novel imaging tool for the diagnosis of aortoenteric fistula and aortic graft infection - A case report Vasc Endovascular Surg 37 5 2003 363 366
    • (2003) Vasc Endovascular Surg , vol.37 , Issue.5 , pp. 363-366
    • Krupnick, A.S.1    Lombardi, J.V.2    Engels, F.H.3
  • 30
    • 74849083109 scopus 로고    scopus 로고
    • Comparison of detection of F-18 fluorodeoxyglucose positron emission tomography and 99mTc-hexamethylpropylene amine oxime labelled leukocyte scintigraphy for an aortic graft infection
    • E. Gardet, R. Addas, and J. Monteil Comparison of detection of F-18 fluorodeoxyglucose positron emission tomography and 99mTc-hexamethylpropylene amine oxime labelled leukocyte scintigraphy for an aortic graft infection Interact Cardiovasc Thorac Surg 10 1 2010 142 143
    • (2010) Interact Cardiovasc Thorac Surg , vol.10 , Issue.1 , pp. 142-143
    • Gardet, E.1    Addas, R.2    Monteil, J.3
  • 31
    • 0033948146 scopus 로고    scopus 로고
    • Infection imaging using whole-body FDG-PET
    • K.D. Stumpe, H. Dazzi, and A. Schaffner Infection imaging using whole-body FDG-PET Eur J Nucl Med 27 7 2000 822 832
    • (2000) Eur J Nucl Med , vol.27 , Issue.7 , pp. 822-832
    • Stumpe, K.D.1    Dazzi, H.2    Schaffner, A.3
  • 32
    • 37849044994 scopus 로고    scopus 로고
    • The use of positron emission tomography with (18)F-fluorodeoxyglucose for the diagnosis of vascular graft infection
    • P. Lauwers, S. Van den Broeck, and L. Carp The use of positron emission tomography with (18)F-fluorodeoxyglucose for the diagnosis of vascular graft infection Angiology 58 6 2007 717 724
    • (2007) Angiology , vol.58 , Issue.6 , pp. 717-724
    • Lauwers, P.1    Van Den Broeck, S.2    Carp, L.3
  • 33
    • 27644514797 scopus 로고    scopus 로고
    • Detection of aortic graft infection by fluorodeoxyglucose positron emission tomography: Comparison with computed tomographic findings
    • K. Fukuchi, Y. Ishida, and M. Higashi Detection of aortic graft infection by fluorodeoxyglucose positron emission tomography: Comparison with computed tomographic findings J Vasc Surg 42 5 2005 919 925
    • (2005) J Vasc Surg , vol.42 , Issue.5 , pp. 919-925
    • Fukuchi, K.1    Ishida, Y.2    Higashi, M.3
  • 34
    • 34547727202 scopus 로고    scopus 로고
    • Prosthetic vascular graft infection: The role of 18F-FDG PET/CT
    • Z. Keidar, A. Engel, and A. Hoffman Prosthetic vascular graft infection: The role of 18F-FDG PET/CT J Nucl Med 48 8 2007 1230 1236
    • (2007) J Nucl Med , vol.48 , Issue.8 , pp. 1230-1236
    • Keidar, Z.1    Engel, A.2    Hoffman, A.3
  • 35
    • 11144346097 scopus 로고    scopus 로고
    • Diagnosis of vascular prosthesis infection with FDG-PET/CT
    • P. Stadler, O. Bilohlavek, and M. Spacek Diagnosis of vascular prosthesis infection with FDG-PET/CT J Vasc Surg 40 6 2004 1246 1247
    • (2004) J Vasc Surg , vol.40 , Issue.6 , pp. 1246-1247
    • Stadler, P.1    Bilohlavek, O.2    Spacek, M.3
  • 36
    • 0037908634 scopus 로고    scopus 로고
    • PET/CT using 2-deoxy-2-[18F]fluoro-D-glucose for the evaluation of suspected infected vascular graft
    • Z. Keidar, A. Engel, and S. Nitecki PET/CT using 2-deoxy-2-[18F]fluoro-D- glucose for the evaluation of suspected infected vascular graft Mol Imaging Biol 5 1 2003 23 25
    • (2003) Mol Imaging Biol , vol.5 , Issue.1 , pp. 23-25
    • Keidar, Z.1    Engel, A.2    Nitecki, S.3
  • 37
    • 33947581676 scopus 로고    scopus 로고
    • Detection of aortic graft infection by 18-fluorodeoxyglucose positron emission tomography combined with computed tomography
    • G. Tegler, J. Sorensen, and M. Bjorck Detection of aortic graft infection by 18-fluorodeoxyglucose positron emission tomography combined with computed tomography J Vasc Surg 45 4 2007 828 830
    • (2007) J Vasc Surg , vol.45 , Issue.4 , pp. 828-830
    • Tegler, G.1    Sorensen, J.2    Bjorck, M.3
  • 38
    • 33746450490 scopus 로고    scopus 로고
    • Role of FDG-PET and PET/CT in the diagnosis of prolonged febrile states
    • M. Jaruskova, and O. Belohlavek Role of FDG-PET and PET/CT in the diagnosis of prolonged febrile states Eur J Nucl Med Mol Imaging 33 8 2006 913 918
    • (2006) Eur J Nucl Med Mol Imaging , vol.33 , Issue.8 , pp. 913-918
    • Jaruskova, M.1    Belohlavek, O.2
  • 39
    • 77957344861 scopus 로고    scopus 로고
    • Chronic vascular graft infection with fistula to bone causing vertebral osteomyelitis, imaged with F-18 FDG PET/CT
    • W. Makis, and J. Stern Chronic vascular graft infection with fistula to bone causing vertebral osteomyelitis, imaged with F-18 FDG PET/CT Clin Nucl Med 35 10 2010 794 796
    • (2010) Clin Nucl Med , vol.35 , Issue.10 , pp. 794-796
    • Makis, W.1    Stern, J.2
  • 40
    • 84859165371 scopus 로고    scopus 로고
    • Accuracy of FDG-PET-CT in the diagnostic work-up of vascular prosthetic graft infection
    • J.L. Bruggink, A.W. Glaudemans, and B.R. Saleem Accuracy of FDG-PET-CT in the diagnostic work-up of vascular prosthetic graft infection Eur J Vasc Endovasc Surg 40 3 2010 348 354
    • (2010) Eur J Vasc Endovasc Surg , vol.40 , Issue.3 , pp. 348-354
    • Bruggink, J.L.1    Glaudemans, A.W.2    Saleem, B.R.3
  • 41
    • 64649094538 scopus 로고    scopus 로고
    • Diagnostics of "non-acute" vascular prosthesis infection using 18F-FDG PET/CT: Our experience with 96 prostheses
    • M. Spacek, O. Belohlavek, and J. Votrubova Diagnostics of "non-acute" vascular prosthesis infection using 18F-FDG PET/CT: Our experience with 96 prostheses Eur J Nucl Med Mol Imaging 36 5 2009 850 858
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.5 , pp. 850-858
    • Spacek, M.1    Belohlavek, O.2    Votrubova, J.3
  • 42
    • 84878186821 scopus 로고    scopus 로고
    • Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography
    • Y. Tokuda, H. Oshima, and Y. Araki Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography Eur J Cardiothorac Surg 2013
    • (2013) Eur J Cardiothorac Surg
    • Tokuda, Y.1    Oshima, H.2    Araki, Y.3
  • 43
    • 33845426032 scopus 로고    scopus 로고
    • Inflammatory F-18 fluorodeoxyglucose uptake over arterial bypass prosthesis seen on positron emission tomography can predict acute vascular events
    • M. Duet, J.P. Laissy, and B. Paulmier Inflammatory F-18 fluorodeoxyglucose uptake over arterial bypass prosthesis seen on positron emission tomography can predict acute vascular events J Nucl Cardiol 13 6 2006 876 879
    • (2006) J Nucl Cardiol , vol.13 , Issue.6 , pp. 876-879
    • Duet, M.1    Laissy, J.P.2    Paulmier, B.3
  • 44
    • 53749090533 scopus 로고    scopus 로고
    • High 18F-FDG uptake in synthetic aortic vascular grafts on PET/CT in symptomatic and asymptomatic patients
    • J. Wasselius, J. Malmstedt, and B. Kalin High 18F-FDG uptake in synthetic aortic vascular grafts on PET/CT in symptomatic and asymptomatic patients J Nucl Med 49 10 2008 1601 1605
    • (2008) J Nucl Med , vol.49 , Issue.10 , pp. 1601-1605
    • Wasselius, J.1    Malmstedt, J.2    Kalin, B.3
  • 45
    • 84895063308 scopus 로고    scopus 로고
    • 18F-FDG uptake in uninfected prosthetic vascular grafts: Frequency, patterns, intensity, & changes over time
    • M.B. Tomas, L. Rivera, and K.J. Nichols 18F-FDG uptake in uninfected prosthetic vascular grafts: Frequency, patterns, intensity, & changes over time J Nucl Med 53 2012 540
    • (2012) J Nucl Med , Issue.53 , pp. 540
    • Tomas, M.B.1    Rivera, L.2    Nichols, K.J.3
  • 46
    • 0030254972 scopus 로고    scopus 로고
    • Normal physiological and benign pathological variants of 18-fluoro-2-deoxyglucose positron-emission tomography scanning: Potential for error in interpretation
    • G.J. Cook, I. Fogelman, and M.N. Maisey Normal physiological and benign pathological variants of 18-fluoro-2-deoxyglucose positron-emission tomography scanning: Potential for error in interpretation Semin Nucl Med 26 4 1996 308 314
    • (1996) Semin Nucl Med , vol.26 , Issue.4 , pp. 308-314
    • Cook, G.J.1    Fogelman, I.2    Maisey, M.N.3
  • 47
    • 77954995400 scopus 로고    scopus 로고
    • Do hyperglycemia and diabetes affect the incidence of false-negative 18F-FDG PET/CT studies in patients evaluated for infection or inflammation and cancer? A comparative analysis
    • Z. Rabkin, O. Israel, and Z. Keidar Do hyperglycemia and diabetes affect the incidence of false-negative 18F-FDG PET/CT studies in patients evaluated for infection or inflammation and cancer? A comparative analysis J Nucl Med 51 7 2010 1015 1020
    • (2010) J Nucl Med , vol.51 , Issue.7 , pp. 1015-1020
    • Rabkin, Z.1    Israel, O.2    Keidar, Z.3
  • 48
    • 34547767536 scopus 로고    scopus 로고
    • Diagnosis of vascular prosthesis infection: PET or SPECT?
    • L. Burroni, C. D'Alessandria, and A. Signore Diagnosis of vascular prosthesis infection: PET or SPECT? J Nucl Med 48 8 2007 1227 1229
    • (2007) J Nucl Med , vol.48 , Issue.8 , pp. 1227-1229
    • Burroni, L.1    D'Alessandria, C.2    Signore, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.