메뉴 건너뛰기




Volumn , Issue , 2012, Pages 219-222

Using dual-antenna nanosecond pulse near-field sensing technology for non-contact and continuous blood pressure measurement

Author keywords

[No Author keywords available]

Indexed keywords

ANALYSIS SOFTWARES; BLOOD FLOW; BLOOD-PRESSURE MONITORING; CARDIO-VASCULAR DISEASE; CARDIOVASCULAR PARAMETERS; CLINICAL DIAGNOSIS; COMMERCIAL PRODUCTS; CONTINUOUS MEASUREMENTS; HOMECARE APPLICATIONS; LONG TERM MONITORING; MEASUREMENT PROCEDURES; MEASUREMENT RESULTS; MEASURING METHOD; MINIATURE RADARS; NANOSECOND PULSE; NEAR-FIELD; NON-CONTACT; NONINVASIVE METHODS; PRESSURE PARAMETER; PRESSURE SENSITIVE; PULSE WAVE VELOCITY; RADIO FREQUENCY PULSE; SCREENING TECHNOLOGY; SENSING PROBE; SENSING TECHNOLOGY; SYSTOLIC PRESSURE;

EID: 84881081691     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2012.6345909     Document Type: Conference Paper
Times cited : (11)

References (11)
  • 1
    • 0037782343 scopus 로고    scopus 로고
    • Current perspectives on arterial stiffness and pulse pressure in hypertension and cardiovascular diseases
    • M. E. Safar, B. I. Levy, H. Struijker-Boudier, "Current perspectives on arterial stiffness and pulse pressure in hypertension and cardiovascular diseases,", Circulation, 2003, vol. 107, pp. 2864-2869.
    • (2003) Circulation , vol.107 , pp. 2864-2869
    • Safar, M.E.1    Levy, B.I.2    Struijker-Boudier, H.3
  • 2
    • 0029087202 scopus 로고
    • Assessment of arterial distensibility by automatic pulse wave velocity measurement: Validation and clinical application studies
    • R. Asmar, A. Benetos, J. Topouchian, et al, "Assessment of arterial distensibility by automatic pulse wave velocity measurement: validation and clinical application studies," Hypertension, 1995, vol. 26, pp. 485-90.
    • (1995) Hypertension , vol.26 , pp. 485-490
    • Asmar, R.1    Benetos, A.2    Topouchian, J.3
  • 3
    • 0037864017 scopus 로고    scopus 로고
    • A new device for automatic measurements of arterial stiffness and ankle-brachial index
    • M. Y. Cortez-Cooper, J. A. Supak, H. Tanaka, "A new device for automatic measurements of arterial stiffness and ankle-brachial index," Am J Cardiol, 2003, vol. 91, pp. 1519-1522.
    • (2003) Am J Cardiol , vol.91 , pp. 1519-1522
    • Cortez-Cooper, M.Y.1    Supak, J.A.2    Tanaka, H.3
  • 5
    • 0032408206 scopus 로고    scopus 로고
    • Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
    • I. B. Wilkinson, S. A. Fuchs, I. M. Jansen, et al, "Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis," J. Hypertens., 1998, vol. 16, pp. 2079-2084.
    • (1998) J. Hypertens , vol.16 , pp. 2079-2084
    • Wilkinson, I.B.1    Fuchs, S.A.2    Jansen, I.M.3
  • 6
    • 0024661972 scopus 로고
    • On-line doppler ultrasound measurement of aortic compliance and its repeatability in normal subjects
    • S. Kontis, R. G. Gosling," On-line Doppler ultrasound measurement of aortic compliance and its repeatability in normal subjects," Clin Phys Physiol Meas., 1989, vol. 10, pp. 127-135.
    • (1989) Clin Phys Physiol Meas. , vol.10 , pp. 127-135
    • Kontis, S.1    Gosling, R.G.2
  • 7
    • 0023429695 scopus 로고
    • Continuous, real-time, noninvasive monitor of blood pressure: Peñaz methodology applied to the finger
    • R. D. Boehmer, "Continuous, real-time, noninvasive monitor of blood pressure: Peñaz methodology applied to the finger," J Clin Monit., 1987, vol. 3, pp. 282-287.
    • (1987) J Clin Monit. , vol.3 , pp. 282-287
    • Boehmer, R.D.1
  • 8
    • 0036667793 scopus 로고    scopus 로고
    • Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
    • S. Loukougeorgakis, R. Dawson, N. Phillips, et al, "Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method," Physiol Meas., 2002, vol. 23, pp. 581-596.
    • (2002) Physiol Meas. , vol.23 , pp. 581-596
    • Loukougeorgakis, S.1    Dawson, R.2    Phillips, N.3
  • 9
    • 0033048761 scopus 로고    scopus 로고
    • Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: Aging and arterial compliance
    • G. E. McVeigh, C. W. Bratteli, D. J. Morgan, et al, "Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: aging and arterial compliance," Hypertension, 1999, vol. 33, pp. 1392-1398.
    • (1999) Hypertension , vol.33 , pp. 1392-1398
    • McVeigh, G.E.1    Bratteli, C.W.2    Morgan, D.J.3
  • 10
    • 70349335373 scopus 로고    scopus 로고
    • Pulse wave velocity and digital volume pulse as indirect estimators of blood pressure: Pilot study on healthy volunteers
    • J. M. Padilla, E. J. Berjano, J. Sáiz, R. Rodriguez and Fácila, "Pulse wave velocity and digital volume pulse as indirect estimators of blood pressure: pilot study on healthy volunteers.," Cardiovasc Eng., 2009, vol. 9, pp. 104112.
    • (2009) Cardiovasc Eng. , vol.9 , pp. 104112
    • Padilla, J.M.1    Berjano, E.J.2    Sáiz, J.3    Rodriguez, R.4    Fácila5
  • 11
    • 36949018131 scopus 로고    scopus 로고
    • Assessment of relationships between blood pressure, pulse wave velocity and digital volume pulse
    • J. M. Padilla, E. J. Berjano, J. Sáiz, L. Fácila, P. Díaz, S. Mercé, "Assessment of Relationships between Blood Pressure, Pulse Wave Velocity and Digital Volume Pulse," Computers in Cardiology, 2006, vol. 33, pp. 893-896.
    • (2006) Computers in Cardiology , vol.33 , pp. 893-896
    • Padilla, J.M.1    Berjano, E.J.2    Sáiz, J.3    Fácila, L.4    Díaz, P.5    Mercé, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.