메뉴 건너뛰기




Volumn , Issue , 2012, Pages 891-895

Electrode assembly design for transcranial Direct Current Stimulation: A FEM modeling study

Author keywords

[No Author keywords available]

Indexed keywords

CURRENT DISTRIBUTION; CURRENT FLOW DENSITY; DIRECT CURRENT; EDGE CONCENTRATIONS; ELECTRODE ASSEMBLIES; ELECTRODE DESIGN; ELECTRODE PLACEMENT; ELECTRODE SIZE; FEM MODELING; FEM SIMULATIONS; GENERAL PATTERNS; INTEGRATED DESIGNS; METAL ELECTRODES; SKIN BURN; SKIN SURFACES; SOLUTION SALINITY; TRANSCRANIAL;

EID: 84881077100     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2012.6346075     Document Type: Conference Paper
Times cited : (43)

References (15)
  • 1
    • 34047147491 scopus 로고    scopus 로고
    • Perception of comfort during transcranial DC stimulation: Effect of NaCl solution concentration applied to sponge electrodes
    • May
    • J.E. Dundas, G.W. Thickbroom, F.L. Mastaglia, "Perception of comfort during transcranial DC stimulation: effect of NaCl solution concentration applied to sponge electrodes," Clin Neurophysiol., vol. 118, no. 5, pp. 1166-1170, May 2007
    • (2007) Clin Neurophysiol. , vol.118 , Issue.5 , pp. 1166-1170
    • Dundas, J.E.1    Thickbroom, G.W.2    Mastaglia, F.L.3
  • 2
    • 84867575796 scopus 로고    scopus 로고
    • The fade-in - Short stimulation - Fade out approach to sham tDCS-reliable at 1 mA for naïve and experienced subjects, but not investigators
    • Feb. (Epub ahead of print)
    • C.G. Ambras, H. Al-Moyed, L. Chaieb, L. Sarp, A. Antal, W. Paulus, "The fade-in - Short stimulation - Fade out approach to sham tDCS-Reliable at 1 mA for naïve and experienced subjects, but not investigators," Brain Stimul., Feb. 2012. (Epub ahead of print)
    • (2012) Brain Stimul.
    • Ambras, C.G.1    Al-Moyed, H.2    Chaieb, L.3    Sarp, L.4    Antal, A.5    Paulus, W.6
  • 3
    • 79960383704 scopus 로고    scopus 로고
    • Avoiding skin burns with transcranial direct current stimulation: Preliminary considerations
    • Apr.
    • C.K. Loo, D.M. Martin, A. Alonzo, S. Gandevia, P.B. Mitchell, P. Sachdev, "Avoiding skin burns with transcranial direct current stimulation: preliminary considerations," Int. J Neuropsychopharmacol., vol. 14, no. 3, pp. 425-426, Apr. 2011.
    • (2011) Int. J Neuropsychopharmacol. , vol.14 , Issue.3 , pp. 425-426
    • Loo, C.K.1    Martin, D.M.2    Alonzo, A.3    Gandevia, S.4    Mitchell, P.B.5    Sachdev, P.6
  • 4
    • 75149165537 scopus 로고    scopus 로고
    • Anodal skin lesions after treatment with transcranial direct current stimulation
    • Jan.
    • E. Frank, S. Wilfurth, M. Landgrebe, P. Eichhammer, G. Hajak, B. Langguth, "Anodal skin lesions after treatment with transcranial direct current stimulation," Brain Stimul., vol. 3, no. 1, pp. 58-59, Jan. 2010.
    • (2010) Brain Stimul. , vol.3 , Issue.1 , pp. 58-59
    • Frank, E.1    Wilfurth, S.2    Landgrebe, M.3    Eichhammer, P.4    Hajak, G.5    Langguth, B.6
  • 5
    • 33745386477 scopus 로고    scopus 로고
    • Modeling the current distribution during transcranial direct current stimulation
    • Jul.
    • P.C. Miranda, M. Lomarev, M. Hallett, "Modeling the current distribution during transcranial direct current stimulation," Clin. Neurophysiol., vol. 117, no. 7, pp. 1623-1629, Jul. 2006.
    • (2006) Clin. Neurophysiol. , vol.117 , Issue.7 , pp. 1623-1629
    • Miranda, P.C.1    Lomarev, M.2    Hallett, M.3
  • 6
    • 68149086370 scopus 로고    scopus 로고
    • Gyriprecise head model of transcranial direct current stimulation: Improved spatial focality using ring electrode versus conventional rectangular pad
    • Oct.
    • A. Datta, V. Bansal, J. Diaz, J. Patel, D. Reato, M. Bikson, "Gyriprecise head model of transcranial direct current stimulation: improved spatial focality using ring electrode versus conventional rectangular pad," Brain Stimul, vol. 2, no. 4, pp. 201-207, Oct. 2009.
    • (2009) Brain Stimul , vol.2 , Issue.4 , pp. 201-207
    • Datta, A.1    Bansal, V.2    Diaz, J.3    Patel, J.4    Reato, D.5    Bikson, M.6
  • 7
    • 81055156180 scopus 로고    scopus 로고
    • Transcranial direct current stimulation in refactory continuous spikes and waves during slow sleep: A controlled study
    • Nov.
    • E.T. Varga, D. Terney, M.D. Atkins, M. Nikanorova, D.S. Jeppesen, P. Uldall, H. Hjalgrim, S. Beniczky, "Transcranial direct current stimulation in refactory continuous spikes and waves during slow sleep: a controlled study," Epilepsy Res., vol. 97, no. 1-2, pp. 142-145, Nov. 2011.
    • (2011) Epilepsy Res. , vol.97 , Issue.1-2 , pp. 142-145
    • Varga, E.T.1    Terney, D.2    Atkins, M.D.3    Nikanorova, M.4    Jeppesen, D.S.5    Uldall, P.6    Hjalgrim, H.7    Beniczky, S.8
  • 9
    • 34447101128 scopus 로고    scopus 로고
    • Design of electrodes and current limits for low frequency electrical impedance tomography of the brain
    • Jul.
    • O. Gilad, L. Horesh, D.S. Holder, "Design of electrodes and current limits for low frequency electrical impedance tomography of the brain," Med. Biol. Eng. Comput., vol. 45, no. 7, pp. 621-633, Jul. 2007.
    • (2007) Med. Biol. Eng. Comput. , vol.45 , Issue.7 , pp. 621-633
    • Gilad, O.1    Horesh, L.2    Holder, D.S.3
  • 10
    • 0029608828 scopus 로고
    • The electrical characteristics of human skin in vivo
    • Nov.
    • Y.N. Kalia, R.H. Guy, "The electrical characteristics of human skin in vivo," Pharm Res., vol. 12, no. 11, pp. 1605-1613, Nov. 1995.
    • (1995) Pharm Res. , vol.12 , Issue.11 , pp. 1605-1613
    • Kalia, Y.N.1    Guy, R.H.2
  • 11
    • 0022270425 scopus 로고
    • Sensory effects of transient electrical stimulation - Evaluation with a neuroelectric model
    • Dec.
    • J.P. Reilly, V.T. Freeman, W.D. Larkin, "Sensory effects of transient electrical stimulation - evaluation with a neuroelectric model," IEEE Trans. Biomed. Eng., vol. 32, no. 12, pp. 1001-1011, Dec. 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.32 , Issue.12 , pp. 1001-1011
    • Reilly, J.P.1    Freeman, V.T.2    Larkin, W.D.3
  • 12
    • 77954218682 scopus 로고    scopus 로고
    • Electrodes for high defintion transcutaneous DC stimulation for application in drug delivery and electrotherapy, including tDCS
    • Jul.
    • P. Minhas, V. Bansal, J. Patel, J.S. Ho, J. Diaz, A. Datta, M. Bikson, "Electrodes for high defintion transcutaneous DC stimulation for application in drug delivery and electrotherapy, including tDCS," J. Neurosci. Methods., vol. 190, no. 2, pp. 188-197, Jul. 2010.
    • (2010) J. Neurosci. Methods. , vol.190 , Issue.2 , pp. 188-197
    • Minhas, P.1    Bansal, V.2    Patel, J.3    Ho, J.S.4    Diaz, J.5    Datta, A.6    Bikson, M.7
  • 13
    • 79952311305 scopus 로고    scopus 로고
    • Cutaneous perception during tDCS: Role of electrode shape and sponge salinity
    • Apr.
    • P. Minhas, A. Datta, M. Bikson, "Cutaneous perception during tDCS: role of electrode shape and sponge salinity," Clin. Neurophysiol., vol. 122, no. 4, pp. 637-638, Apr. 2011.
    • (2011) Clin. Neurophysiol. , vol.122 , Issue.4 , pp. 637-638
    • Minhas, P.1    Datta, A.2    Bikson, M.3
  • 14
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • Feb.
    • D.R. Merrill, M. Bikson, J.G. Jefferys, "Electrical stimulation of excitable tissue: design of efficacious and safe protocols," J. Neurosci. Methods., vol. 141, no. 2, pp. 171-198, Feb.2005.
    • (2005) J. Neurosci. Methods. , vol.141 , Issue.2 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.G.3
  • 15
    • 77950983944 scopus 로고    scopus 로고
    • Comparing different electrode configurations using the 10-10 international system in tDCS: A finite element model analysis
    • P. Faria, A. Leal, P.C. Miranda, "Comparing different electrode configurations using the 10-10 international system in tDCS: a finite element model analysis," Conf. Proc. IEEE Eng. Med. Biol. Soc., 2009, pp. 1596-1599.
    • (2009) Conf. Proc. IEEE Eng. Med. Biol. Soc. , pp. 1596-1599
    • Faria, P.1    Leal, A.2    Miranda, P.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.