메뉴 건너뛰기




Volumn 180, Issue 11-12, 2013, Pages 1065-1071

Detection of lead(II) using an glassy carbon electrode modified with Nafion, carbon nanotubes and benzo-18-crown-6

Author keywords

Anodic stripping voltammetry; Carbon nanotubes; Crown ether; Lead; Selectivity

Indexed keywords


EID: 84881026448     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-013-1022-7     Document Type: Article
Times cited : (47)

References (31)
  • 1
    • 71749114630 scopus 로고    scopus 로고
    • Highly selective optical-sensing film for lead(II) determination in water samples
    • Ensafi AA, Far AK, Meghdadi S (2009) Highly selective optical-sensing film for lead(II) determination in water samples. J Hazard Mater 172: 1069-1075.
    • (2009) J Hazard Mater , vol.172 , pp. 1069-1075
    • Ensafi, A.A.1    Far, A.K.2    Meghdadi, S.3
  • 2
    • 0033813412 scopus 로고    scopus 로고
    • Environmental lead exposure: a public health problem of global dimensions
    • Tong S, Schirnding YEV, Prapamontol T (2000) Environmental lead exposure: a public health problem of global dimensions. Bull World Health Organ 78: 1068-1077.
    • (2000) Bull World Health Organ , vol.78 , pp. 1068-1077
    • Tong, S.1    Schirnding, Y.E.V.2    Prapamontol, T.3
  • 3
    • 22144464444 scopus 로고    scopus 로고
    • Low-level environmental lead exposure and children's intellectual function: an international pooled analysis
    • Lanphear BP et al (2005) Low-level environmental lead exposure and children's intellectual function: an international pooled analysis. Environ Health Perspect 113: 894-899.
    • (2005) Environ Health Perspect , vol.113 , pp. 894-899
    • Lanphear, B.P.1
  • 4
    • 33947111304 scopus 로고    scopus 로고
    • Lead exposure, IQ, and behaviour in urban 5-7 year olds: does lead affect behaviour only by lowering IQ?
    • Chen A, Cai B, Dietrich KN, Radcliffe J, Rogan WJ (2007) Lead exposure, IQ, and behaviour in urban 5-7 year olds: does lead affect behaviour only by lowering IQ? Pediatrics 119: 650-658.
    • (2007) Pediatrics , vol.119 , pp. 650-658
    • Chen, A.1    Cai, B.2    Dietrich, K.N.3    Radcliffe, J.4    Rogan, W.J.5
  • 5
    • 40549084327 scopus 로고    scopus 로고
    • Very low lead exposures and children's neurodevelopment
    • Bellinger DC (2008) Very low lead exposures and children's neurodevelopment. Curr Opin Pediatr 20: 172-177.
    • (2008) Curr Opin Pediatr , vol.20 , pp. 172-177
    • Bellinger, D.C.1
  • 6
    • 0345276515 scopus 로고
    • Determination of cadmium, lead and copper in water samples by flame atomic-absorption spectrometry with preconcentration by flow-injection on-line sorbent extraction
    • Fang Z, Guo T, Welz B (1991) Determination of cadmium, lead and copper in water samples by flame atomic-absorption spectrometry with preconcentration by flow-injection on-line sorbent extraction. Talanta 38: 613-619.
    • (1991) Talanta , vol.38 , pp. 613-619
    • Fang, Z.1    Guo, T.2    Welz, B.3
  • 7
    • 0034804191 scopus 로고    scopus 로고
    • Determination of heavy metals in soils, sediments and geological materials by ICP-AES and ICP-MS
    • Moor C, Lymberopoulou T, Dietrich VJ (2001) Determination of heavy metals in soils, sediments and geological materials by ICP-AES and ICP-MS. Microchim Acta 136: 123-128.
    • (2001) Microchim. Acta , vol.136 , pp. 123-128
    • Moor, C.1    Lymberopoulou, T.2    Dietrich, V.J.3
  • 8
    • 0028376240 scopus 로고
    • In vivo X-ray fluorescence of lead in bone: review and current issues
    • Todd AC, Chettle DR (1994) In vivo X-ray fluorescence of lead in bone: review and current issues. Environ Health Perspect 102: 172-177.
    • (1994) Environ Health Perspect , vol.102 , pp. 172-177
    • Todd, A.C.1    Chettle, D.R.2
  • 9
    • 0002030318 scopus 로고
    • Determination of lead isotope ratios by inductively coupled plasma-mass spectrometry (ICP-MS)
    • Longerich HP, Fryer BJ, Strong DF (1987) Determination of lead isotope ratios by inductively coupled plasma-mass spectrometry (ICP-MS). Spectrochim Acta B: Atomic Spectrosc 42: 39-48.
    • (1987) Spectrochim Acta B: Atomic Spectrosc , vol.42 , pp. 39-48
    • Longerich, H.P.1    Fryer, B.J.2    Strong, D.F.3
  • 12
    • 0037350774 scopus 로고    scopus 로고
    • Mercury film electrodes: developments, trends and potentialities for electroanalysis
    • Economou A, Fielden PR (2003) Mercury film electrodes: developments, trends and potentialities for electroanalysis. Analyst 128: 205-212.
    • (2003) Analyst , vol.128 , pp. 205-212
    • Economou, A.1    Fielden, P.R.2
  • 13
    • 10344238126 scopus 로고    scopus 로고
    • Square-wave stripping voltammetry for direct determination of eight heavy metals in soil and indoor-airborne particulate matter
    • Farghalya OA, Ghandour MA (2005) Square-wave stripping voltammetry for direct determination of eight heavy metals in soil and indoor-airborne particulate matter. Environ Res 97: 229-235.
    • (2005) Environ Res , vol.97 , pp. 229-235
    • Farghalya, O.A.1    Ghandour, M.A.2
  • 14
    • 77954360905 scopus 로고    scopus 로고
    • A decade with bismuth-based electrodes in electroanalysis
    • Svancara I, Prior C, Hocever SB, Wang J (2010) A decade with bismuth-based electrodes in electroanalysis. Electroanalysis 22: 1405-1420.
    • (2010) Electroanalysis , vol.22 , pp. 1405-1420
    • Svancara, I.1    Prior, C.2    Hocever, S.B.3    Wang, J.4
  • 15
    • 34248657954 scopus 로고    scopus 로고
    • Total inorganic arsenic detection in real water samples using anodic stripping voltammetry and a gold-coated diamond thin-film electrode
    • Song Y, Swain GM (2007) Total inorganic arsenic detection in real water samples using anodic stripping voltammetry and a gold-coated diamond thin-film electrode. Anal Chim Acta 593: 7-12.
    • (2007) Anal Chim Acta , vol.593 , pp. 7-12
    • Song, Y.1    Swain, G.M.2
  • 16
    • 34547589005 scopus 로고    scopus 로고
    • Anodic stripping voltammetry of heavy metals at nanocrystalline boron-doped diamond electrode
    • El Tall O, Renault NJ, Sigaud M, Vittori O (2007) Anodic stripping voltammetry of heavy metals at nanocrystalline boron-doped diamond electrode. Electroanalysis 19: 1152-1159.
    • (2007) Electroanalysis , vol.19 , pp. 1152-1159
    • El Tall, O.1    Renault, N.J.2    Sigaud, M.3    Vittori, O.4
  • 17
    • 0034661524 scopus 로고    scopus 로고
    • Bismuth-coated carbon electrodes for anodic stripping voltammetry
    • Wang J, Lu J, Hocever SB, Farias PAM (2000) Bismuth-coated carbon electrodes for anodic stripping voltammetry. Anal Chem 72: 3218-3222.
    • (2000) Anal Chem , vol.72 , pp. 3218-3222
    • Wang, J.1    Lu, J.2    Hocever, S.B.3    Farias, P.A.M.4
  • 18
    • 20444453768 scopus 로고    scopus 로고
    • Adsorptive stripping voltammetric detection of daunomycin at a bismuth bulk electrode
    • Buckova M, Grundler P, Flechsig GU (2005) Adsorptive stripping voltammetric detection of daunomycin at a bismuth bulk electrode. Electroanalysis 17: 440-444.
    • (2005) Electroanalysis , vol.17 , pp. 440-444
    • Buckova, M.1    Grundler, P.2    Flechsig, G.U.3
  • 19
    • 0001320108 scopus 로고
    • Stripping voltammetry of silver(I) with a carbon-paste electrode modified with thiacrown compounds
    • Tanaka S, Yoshida H (1989) Stripping voltammetry of silver(I) with a carbon-paste electrode modified with thiacrown compounds. Talanta 36: 1044-1046.
    • (1989) Talanta , vol.36 , pp. 1044-1046
    • Tanaka, S.1    Yoshida, H.2
  • 20
    • 0001129491 scopus 로고
    • Preconcentration and voltammetric measurement of mercury with a crown-ether modified carbon-paste electrode
    • Wang J, Bonakdar M (1988) Preconcentration and voltammetric measurement of mercury with a crown-ether modified carbon-paste electrode. Talanta 35: 277-280.
    • (1988) Talanta , vol.35 , pp. 277-280
    • Wang, J.1    Bonakdar, M.2
  • 21
    • 0342819025 scopus 로고
    • Helical microtubules of graphite carbon
    • Iijima S (1991) Helical microtubules of graphite carbon. Nature 354: 56-58.
    • (1991) Nature , vol.354 , pp. 56-58
    • Iijima, S.1
  • 22
    • 79960823267 scopus 로고    scopus 로고
    • Carbon Nanotubes/Ionophore modified electrode for anodic stripping determination of lead
    • Lou T, Pan D, Wang Y, Jiang L, Qin W (2011) Carbon Nanotubes/Ionophore modified electrode for anodic stripping determination of lead. Anal Lett 44: 1746-1757.
    • (2011) Anal Lett , vol.44 , pp. 1746-1757
    • Lou, T.1    Pan, D.2    Wang, Y.3    Jiang, L.4    Qin, W.5
  • 23
    • 0001535281 scopus 로고    scopus 로고
    • Voltammetric determination of lead at chemically modified electrodes based on crown ethers
    • Ijeri VS, Srivastava AK (2001) Voltammetric determination of lead at chemically modified electrodes based on crown ethers. Anal Sci 17: 605-608.
    • (2001) Anal Sci , vol.17 , pp. 605-608
    • Ijeri, V.S.1    Srivastava, A.K.2
  • 26
    • 84855347557 scopus 로고    scopus 로고
    • Square wave anodic stripping voltammetric determination of lead (II) using glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes
    • He X, Chen L, Xie X, Su Z, Qin C, Liu Y, Ma M et al (2012) Square wave anodic stripping voltammetric determination of lead (II) using glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes. Microchim Acta 176: 81-89.
    • (2012) Microchim Acta , vol.176 , pp. 81-89
    • He, X.1    Chen, L.2    Xie, X.3    Su, Z.4    Qin, C.5    Liu, Y.6    Ma, M.7
  • 27
    • 84990101529 scopus 로고
    • The discovery of crown ethers (noble lecture)
    • Pedersen CJ (1988) The discovery of crown ethers (noble lecture). Angew Chem Int Ed 27: 1021-1027.
    • (1988) Angew Chem Int Ed , vol.27 , pp. 1021-1027
    • Pedersen, C.J.1
  • 29
    • 0036714718 scopus 로고    scopus 로고
    • Trace analysis of lead at a Nafion-modified electrode using square-wave anodic stripping voltammetry
    • Crowley K, Cassidy J (2002) Trace analysis of lead at a Nafion-modified electrode using square-wave anodic stripping voltammetry. Electroanalysis 14: 1077-1082.
    • (2002) Electroanalysis , vol.14 , pp. 1077-1082
    • Crowley, K.1    Cassidy, J.2
  • 30
    • 49149090039 scopus 로고    scopus 로고
    • 2+ using a carbon nanotube/Nafion composite film-modified electrode
    • 2+ using a carbon nanotube/Nafion composite film-modified electrode. J Appl Electrochem 38: 1223-1227.
    • (2008) J Appl Electrochem , vol.38 , pp. 1223-1227
    • Sun, D.1    Sun, Z.2
  • 31
    • 67249107971 scopus 로고    scopus 로고
    • Nanomaterial/ionophore-based electrode for anodic stripping voltammetric determination of lead: an electrochemical sensing platform toward heavy metals
    • Pan D, Wang Y, Chen Z, Lou T, Qin W (2009) Nanomaterial/ionophore-based electrode for anodic stripping voltammetric determination of lead: an electrochemical sensing platform toward heavy metals. Anal Chem 81: 5088-5094.
    • (2009) Anal Chem , vol.81 , pp. 5088-5094
    • Pan, D.1    Wang, Y.2    Chen, Z.3    Lou, T.4    Qin, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.