메뉴 건너뛰기




Volumn 7, Issue 3, 2013, Pages 159-169

Virtual prototyping of a new intramedullary nail for tibial fractures

Author keywords

Intramedullary nail; Non linear FEM analyses; Parametric CAD model; Redesign; Virtual prototyping

Indexed keywords

INTRAMEDULLARY NAILS; NONLINEAR FEM; PARAMETRIC CAD; REDESIGN; VIRTUAL PROTOTYPING;

EID: 84881025953     PISSN: 19552513     EISSN: 19552505     Source Type: Journal    
DOI: 10.1007/s12008-012-0175-7     Document Type: Article
Times cited : (17)

References (27)
  • 1
    • 0030033440 scopus 로고    scopus 로고
    • The rationales of interlocking nailing of the femur, tibia, and humerus: an overview
    • Brumback, R. J.: The rationales of interlocking nailing of the femur, tibia, and humerus: an overview. Clin. Orthop. 324, 292-320 (1996).
    • (1996) Clin. Orthop. , vol.324 , pp. 292-320
    • Brumback, R.J.1
  • 3
    • 33846028185 scopus 로고    scopus 로고
    • Failure of the spiral blade and intramedullary nail in the treatment of ipsilateral femoral neck and shaft fractures
    • Amin, A., Mahaluxmivala, J., Ramkumar, U., Hill, R.: Failure of the spiral blade and intramedullary nail in the treatment of ipsilateral femoral neck and shaft fractures. Injury Extra 38, 84-87 (2007).
    • (2007) Injury Extra , vol.38 , pp. 84-87
    • Amin, A.1    Mahaluxmivala, J.2    Ramkumar, U.3    Hill, R.4
  • 5
    • 0021950634 scopus 로고
    • The results of plating humeral shaft fractures in patients with multiple injuries
    • Bell, M. J., Beauchamp, C. G., Kellam, J. K., McMurtry, R. Y.: The results of plating humeral shaft fractures in patients with multiple injuries. J. Bone Joint Surg. 67B, 293-296 (1985).
    • (1985) J. Bone Joint Surg. , vol.67 , pp. 293-296
    • Bell, M.J.1    Beauchamp, C.G.2    Kellam, J.K.3    McMurtry, R.Y.4
  • 8
    • 0022506671 scopus 로고
    • Biomechanical performance of locked intramedullary nail systems in comminuted femoral shaft fractures
    • Johnson, K. D., Tencer, A. F., Blumenthal, S., August, A., Johnston, U.: Biomechanical performance of locked intramedullary nail systems in comminuted femoral shaft fractures. Clin. Orthop. Relat. Res. 206, 84 (1986).
    • (1986) Clin. Orthop. Relat. Res. , vol.206 , pp. 84
    • Johnson, K.D.1    Tencer, A.F.2    Blumenthal, S.3    August, A.4    Johnston, U.5
  • 9
    • 33746496124 scopus 로고    scopus 로고
    • A biomechanical comparison of unlocked or locked reamed intramedullary nails in the treatment of mid-third simple transverse femoral shaft fractures
    • Wu, C. C., Tai, C. L.: A biomechanical comparison of unlocked or locked reamed intramedullary nails in the treatment of mid-third simple transverse femoral shaft fractures. Chang Gung Med. J. 29, 275-282 (2006).
    • (2006) Chang Gung Med. J. , vol.29 , pp. 275-282
    • Wu, C.C.1    Tai, C.L.2
  • 10
    • 1542454992 scopus 로고
    • Interlocking intramedullary nailing of the femur: current concepts
    • Russell, T. A., Taylor, J. C.: Interlocking intramedullary nailing of the femur: current concepts. Semin. Orthop. 1, 217-231 (1986).
    • (1986) Semin. Orthop. , vol.1 , pp. 217-231
    • Russell, T.A.1    Taylor, J.C.2
  • 11
    • 0029943542 scopus 로고    scopus 로고
    • The risk of neurovascular injury with distal locking screws of humeral intramedullary nails
    • Rupp, R. E., Chrissos, M. G., Ebraheim, N. A.: The risk of neurovascular injury with distal locking screws of humeral intramedullary nails. Orthopedics 19, 593-595 (1996).
    • (1996) Orthopedics , vol.19 , pp. 593-595
    • Rupp, R.E.1    Chrissos, M.G.2    Ebraheim, N.A.3
  • 12
    • 38749144741 scopus 로고    scopus 로고
    • Targeting device for intramedullary nails: a new high-stable mechanical guide; Injury
    • Arlettaz, Y., Akiki, A., Chevalley, F., Leyvraz, P. F.: Targeting device for intramedullary nails: a new high-stable mechanical guide; Injury. Int. J. Care Inj. 39, 170-175 (2008).
    • (2008) Int. J. Care Inj. , vol.39 , pp. 170-175
    • Arlettaz, Y.1    Akiki, A.2    Chevalley, F.3    Leyvraz, P.F.4
  • 13
    • 0037403882 scopus 로고    scopus 로고
    • Experimental model for a new distal locking aiming device for solid intramedullary tibia nails
    • Abdlslama, Kalid M., Bonnaire, F.: Experimental model for a new distal locking aiming device for solid intramedullary tibia nails. Inj. Int. J. Care Inj. 34, 363-366 (2003).
    • (2003) Inj. Int. J. Care Inj. , vol.34 , pp. 363-366
    • Abdlslama Kalid, M.1    Bonnaire, F.2
  • 14
    • 0024518018 scopus 로고
    • Humeral locking nail: a preliminary report
    • Seidel, H.: Humeral locking nail: a preliminary report. Orthopedics 12, 219-226 (1989).
    • (1989) Orthopedics , vol.12 , pp. 219-226
    • Seidel, H.1
  • 15
    • 0033847788 scopus 로고    scopus 로고
    • Development and testing of a new self-locking intramedullary nail system: testing of handling aspects and mechanical properties. Injury
    • Knothe, U., Knothe, M. L., Klaue, K., Perren, S. M.: Development and testing of a new self-locking intramedullary nail system: testing of handling aspects and mechanical properties. Injury. Int. J. Care Inj. 31, 617-626 (2000).
    • (2000) Int. J. Care Inj. , vol.31 , pp. 617-626
    • Knothe, U.1    Knothe, M.L.2    Klaue, K.3    Perren, S.M.4
  • 17
    • 33744953718 scopus 로고    scopus 로고
    • Evaluation and improvement of the efficiency of the Seidel humeral nail by numerical-experimental analysis of the bone-implant contact
    • Giudice, F., La Rosa, G., Russo, T., Varsalona, R.: Evaluation and improvement of the efficiency of the Seidel humeral nail by numerical-experimental analysis of the bone-implant contact. Med. Eng. Phys. 28, 682-693 (2006).
    • (2006) Med. Eng. Phys. , vol.28 , pp. 682-693
    • Giudice, F.1    La Rosa, G.2    Russo, T.3    Varsalona, R.4
  • 20
    • 84881026600 scopus 로고    scopus 로고
    • Accessed 22 March 2009
    • http://www. bioimpianti. it/linea_trauma_omero-Clos. html (2009). Accessed 22 March 2009.
    • (2009)
  • 21
    • 84881024221 scopus 로고    scopus 로고
    • Accessed 17 Jan 2011
    • http://www. synthes. com/ (2011). Accessed 17 Jan 2011.
    • (2011)
  • 22
    • 84881023019 scopus 로고    scopus 로고
    • Accessed 18 Oct 2008
    • http://www. 3dcontentcentral. com/ (2008). Accessed 18 Oct 2008.
    • (2008)
  • 23
    • 0026990532 scopus 로고
    • A comparison of the fatigue behavior of human trabecular and cortical bone tissue
    • Goldstein, S. A., Choi, K.: A comparison of the fatigue behavior of human trabecular and cortical bone tissue. J. Biomech. 25, 1371-1381 (1992).
    • (1992) J. Biomech. , vol.25 , pp. 1371-1381
    • Goldstein, S.A.1    Choi, K.2
  • 26
    • 84881024475 scopus 로고    scopus 로고
    • Solid modeling and static finite element analysis of the human tibia
    • Mechanical, Materials and Aerospace Engineering Department, College of Engineering University of Central Florida, Orlando, Florida
    • Ionescu, I., Conway, T., Schonning, A, Almutairi, M., Nicholson, D. W.: Solid modeling and static finite element analysis of the human tibia. Mechanical, Materials and Aerospace Engineering Department, College of Engineering University of Central Florida, Orlando, Florida (2003).
    • (2003)
    • Ionescu, I.1    Conway, T.2    Schonning, A.3    Almutairi, M.4    Nicholson, D.W.5
  • 27
    • 39249085417 scopus 로고    scopus 로고
    • A new intramedullary nailing device for the treatment of femoral shaft fractures: a biomechanical study
    • Wang, G., Pan, T., Peng, X., Wang, J.: A new intramedullary nailing device for the treatment of femoral shaft fractures: a biomechanical study. Clin. Biomech. 23, 305-312 (2008).
    • (2008) Clin. Biomech. , vol.23 , pp. 305-312
    • Wang, G.1    Pan, T.2    Peng, X.3    Wang, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.