메뉴 건너뛰기




Volumn 200, Issue 6, 2013, Pages

Adaptive 4D volume perfusion CT of lung cancer: Effects of computerized motion correction and the range of volume coverage on measurement reproducibility

Author keywords

Lung cancer; Motion correction; Perfusion CT; Reproducibility; Tumor coverage

Indexed keywords

ADAPTIVE FOUR DIMENSIONAL VOLUME PERFUSION COMPUTER ASSISTED TOMOGRAPHY; ADULT; AGED; ARTICLE; BLOOD VOLUME; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; LUNG CANCER; MALE; PERMEABILITY; PRIORITY JOURNAL; PROCESS OPTIMIZATION; QUALITY CONTROL PROCEDURES; REPEAT PROCEDURE; REPRODUCIBILITY; TUMOR BLOOD FLOW; BLOOD FLOW VELOCITY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER PROGRAM; FOUR DIMENSIONAL COMPUTED TOMOGRAPHY; LUNG TUMOR; METHODOLOGY; MIDDLE AGED; MOTION; PROSPECTIVE STUDY; RADIOGRAPHY; VASCULARIZATION; VERY ELDERLY;

EID: 84880964698     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.12.9458     Document Type: Article
Times cited : (20)

References (20)
  • 1
    • 33845490014 scopus 로고    scopus 로고
    • Paclitaxel-carboplatin alone or with bevacizumab for non-small-cell lung cancer
    • Sandler A, Gray R, Perry MC, et al. Paclitaxel-carboplatin alone or with bevacizumab for non-small-cell lung cancer. N Engl J Med 2006; 355:2542-2550
    • (2006) N Engl J Med , vol.355 , pp. 2542-2550
    • Sandler, A.1    Gray, R.2    Perry, M.C.3
  • 2
    • 22044445517 scopus 로고    scopus 로고
    • Erlotinib in previously treated nonsmall-cell lung cancer
    • National Cancer Institute of Canada Clinical Trials Group
    • Shepherd FA, Rodrigues Pereira J, Ciuleanu T, et al.; National Cancer Institute of Canada Clinical Trials Group. Erlotinib in previously treated nonsmall-cell lung cancer. N Engl J Med 2005; 353:123-132
    • (2005) N Engl J Med , vol.353 , pp. 123-132
    • Shepherd, F.A.1    Rodrigues Pereira, J.2    Ciuleanu, T.3
  • 3
    • 57849117384 scopus 로고    scopus 로고
    • New Response Evaluation Criteria in Solid Tumours: Revised RECIST guideline (version 11)
    • Eisenhauer EA, Therasse P, Bogaerts J, et al. New Response Evaluation Criteria in Solid Tumours: revised RECIST guideline (version 1.1). Eur J Cancer 2009; 45:228-247
    • (2009) Eur J Cancer , vol.45 , pp. 228-247
    • Eisenhauer, E.A.1    Therasse, P.2    Bogaerts, J.3
  • 4
    • 0036780251 scopus 로고    scopus 로고
    • Clinical translation of angiogenesis inhibitors
    • Kerbel R, Folkman J. Clinical translation of angiogenesis inhibitors. Nat Rev Cancer 2002; 2:727-739
    • (2002) Nat Rev Cancer , vol.2 , pp. 727-739
    • Kerbel, R.1    Folkman, J.2
  • 5
    • 0642307227 scopus 로고    scopus 로고
    • Phase i trial of the antivascular agent combretastatin A4 phosphate on a 5-day schedule to patients with cancer: Magnetic resonance imaging evidence for altered tumor blood flow
    • Stevenson JP, Rosen M, Sun W, et al. Phase I trial of the antivascular agent combretastatin A4 phosphate on a 5-day schedule to patients with cancer: magnetic resonance imaging evidence for altered tumor blood flow. J Clin Oncol 2003; 21:4428-4438
    • (2003) J Clin Oncol , vol.21 , pp. 4428-4438
    • Stevenson, J.P.1    Rosen, M.2    Sun, W.3
  • 6
    • 33748992003 scopus 로고    scopus 로고
    • Quantitative assessment of lung cancer perfusion using MDCT: Does measurement reproducibility improve with greater tumor volume coverage?
    • Ng QS, Goh V, Klotz E, et al. Quantitative assessment of lung cancer perfusion using MDCT: does measurement reproducibility improve with greater tumor volume coverage? AJR 2006; 187:1079-1084
    • (2006) AJR , vol.187 , pp. 1079-1084
    • Ng, Q.S.1    Goh, V.2    Klotz, E.3
  • 7
    • 33646136023 scopus 로고    scopus 로고
    • Lung cancer perfusion at multi-detector row CT: Reproducibility of whole tumor quantitative measurements
    • Ng QS, Goh V, Fichte H, et al. Lung cancer perfusion at multi-detector row CT: reproducibility of whole tumor quantitative measurements. Radiology 2006; 239:547-553
    • (2006) Radiology , vol.239 , pp. 547-553
    • Ng, Q.S.1    Goh, V.2    Fichte, H.3
  • 8
    • 84860389713 scopus 로고    scopus 로고
    • Reproducibility of CT perfusion parameters in liver tumors and normal liver
    • Ng CS, Chandler AG, Wei W, et al. Reproducibility of CT perfusion parameters in liver tumors and normal liver. Radiology 2011; 260:762-770
    • (2011) Radiology , vol.260 , pp. 762-770
    • Ng, C.S.1    Chandler, A.G.2    Wei, W.3
  • 9
    • 84865272078 scopus 로고    scopus 로고
    • Intraobserver and interobserver agreement of volume perfusion CT (VPCT) measurements in patients with lung lesions
    • Sauter AW, Merkle A, Schulze M, et al. Intraobserver and interobserver agreement of volume perfusion CT (VPCT) measurements in patients with lung lesions. Eur J Radiol 2012; 81:2853-2859
    • (2012) Eur J Radiol , vol.81 , pp. 2853-2859
    • Sauter, A.W.1    Merkle, A.2    Schulze, M.3
  • 10
    • 70349684980 scopus 로고    scopus 로고
    • Tumor response in patients with advanced non-small cell lung cancer: Perfusion CT evaluation of chemotherapy and radiation therapy
    • Wang J, Wu N, Cham MD, Song Y. Tumor response in patients with advanced non-small cell lung cancer: perfusion CT evaluation of chemotherapy and radiation therapy. AJR 2009; 193:1090-1096
    • (2009) AJR , vol.193 , pp. 1090-1096
    • Wang, J.1    Wu, N.2    Cham, M.D.3    Song, Y.4
  • 11
    • 78649650204 scopus 로고    scopus 로고
    • Assessment of non-small cell lung cancer perfusion: Pathologic-CT correlation in 15 patients
    • Tacelli N, Remy-Jardin M, Copin MC, et al. Assessment of non-small cell lung cancer perfusion: pathologic-CT correlation in 15 patients. Radiology 2010; 257:863-871
    • (2010) Radiology , vol.257 , pp. 863-871
    • Tacelli, N.1    Remy-Jardin, M.2    Copin, M.C.3
  • 12
    • 79955002324 scopus 로고    scopus 로고
    • Wholetumor perfusion CT in patients with advanced lung adenocarcinoma treated with conventional and antiangiogenetic chemotherapy: Initial experience
    • Fraioli F, Anzidei M, Zaccagna F, et al. Wholetumor perfusion CT in patients with advanced lung adenocarcinoma treated with conventional and antiangiogenetic chemotherapy: initial experience. Radiology 2011; 259:574-582
    • (2011) Radiology , vol.259 , pp. 574-582
    • Fraioli, F.1    Anzidei, M.2    Zaccagna, F.3
  • 13
    • 79952340035 scopus 로고    scopus 로고
    • Differentiation of malignant and benign pulmonary nodules with quantitative first-pass 320-detector row perfusion CT versus FDG PET/CT
    • Ohno Y, Koyama H, Matsumoto K, et al. Differentiation of malignant and benign pulmonary nodules with quantitative first-pass 320-detector row perfusion CT versus FDG PET/CT. Radiology 2011; 258:599-609
    • (2011) Radiology , vol.258 , pp. 599-609
    • Ohno, Y.1    Koyama, H.2    Matsumoto, K.3
  • 14
    • 82955162511 scopus 로고    scopus 로고
    • Effect of scan time on perfusion and flow extraction product (K-trans) measurements in lung cancer using low-dose volume perfusion CT (VPCT)
    • Spira D, Gerlach JD, Spira SM, Schulze M, Sauter A, Horger M. Effect of scan time on perfusion and flow extraction product (K-trans) measurements in lung cancer using low-dose volume perfusion CT (VPCT). Acad Radiol 2012; 19:78-83
    • (2012) Acad Radiol , vol.19 , pp. 78-83
    • Spira, D.1    Gerlach, J.D.2    Spira, S.M.3    Schulze, M.4    Sauter, A.5    Horger, M.6
  • 15
    • 0034913780 scopus 로고    scopus 로고
    • Standardized perfusion value: Universal CT contrast enhancement scale that correlates with FDG PET in lung nodules
    • Miles KA, Griffiths MR, Fuentes MA. Standardized perfusion value: universal CT contrast enhancement scale that correlates with FDG PET in lung nodules. Radiology 2001; 220:548-553
    • (2001) Radiology , vol.220 , pp. 548-553
    • Miles, K.A.1    Griffiths, M.R.2    Fuentes, M.A.3
  • 16
    • 84155172940 scopus 로고    scopus 로고
    • CT perfusion of renal cell carcinoma: Impact of volume coverage on quantitative analysis
    • Reiner CS, Goetti R, Eberli D, et al. CT perfusion of renal cell carcinoma: impact of volume coverage on quantitative analysis. Invest Radiol 2012; 47:33-40
    • (2012) Invest Radiol , vol.47 , pp. 33-40
    • Reiner, C.S.1    Goetti, R.2    Eberli, D.3
  • 18
    • 0025765943 scopus 로고
    • Measurement of tissue perfusion by dynamic computed tomography
    • Miles KA. Measurement of tissue perfusion by dynamic computed tomography. Br J Radiol 1991; 64:409-412
    • (1991) Br J Radiol , vol.64 , pp. 409-412
    • Miles, K.A.1
  • 19
    • 0020956774 scopus 로고
    • Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
    • Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 1983; 3:1-7
    • (1983) J Cereb Blood Flow Metab , vol.3 , pp. 1-7
    • Patlak, C.S.1    Blasberg, R.G.2    Fenstermacher, J.D.3
  • 20
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.