메뉴 건너뛰기




Volumn 200, Issue 6, 2013, Pages

Lowering radiation exposure in CT angiography using automated tube potential selection and optimized iodine delivery rate

Author keywords

Contrast material; CT angiography; High pitch CT angiography; Iodine delivery rate; Radiation dose reduction

Indexed keywords

IOMEPROL; CONTRAST MEDIUM; DRUG DERIVATIVE; IOPAMIDOL;

EID: 84880929321     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.12.9635     Document Type: Article
Times cited : (25)

References (22)
  • 1
    • 0042343644 scopus 로고    scopus 로고
    • Thoracic involvement of type A aortic dissection and intramural hematoma: Diagnostic accuracy-comparison of emergency helical CT and surgical findings
    • Yoshida S, Akiba H, Tamakawa M, et al. Thoracic involvement of type A aortic dissection and intramural hematoma: diagnostic accuracy-comparison of emergency helical CT and surgical findings. Radiology 2003; 228:430-435
    • (2003) Radiology , vol.228 , pp. 430-435
    • Yoshida, S.1    Akiba, H.2    Tamakawa, M.3
  • 2
    • 76849100384 scopus 로고    scopus 로고
    • MDCT evaluation of acute aortic syndrome
    • Yoo SM, Lee HY, White CS. MDCT evaluation of acute aortic syndrome. Thorac Surg Clin 2010; 20:149-165
    • (2010) Thorac Surg Clin , vol.20 , pp. 149-165
    • Yoo, S.M.1    Lee, H.Y.2    White, C.S.3
  • 3
    • 64249163592 scopus 로고    scopus 로고
    • Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms
    • Alerci M, Oberson M, Fogliata A, Gallino A, Vock P, Wyttenbach R. Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms. Eur Radiol 2009; 19:1223-1231
    • (2009) Eur Radiol , vol.19 , pp. 1223-1231
    • Alerci, M.1    Oberson, M.2    Fogliata, A.3    Gallino, A.4    Vock, P.5    Wyttenbach, R.6
  • 4
    • 79954492455 scopus 로고    scopus 로고
    • Multidetector computed tomography in transcatheter aortic valve implantation
    • Leipsic J, Gurvitch R, LaBounty TM, et al. Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 2011; 4:416-429
    • (2011) JACC Cardiovasc Imaging , vol.4 , pp. 416-429
    • Leipsic, J.1    Gurvitch, R.2    Labounty, T.M.3
  • 5
    • 84857055684 scopus 로고    scopus 로고
    • Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode
    • Wuest W, Anders K, Schuhbaeck A, et al. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol 2012; 22:51-58
    • (2012) Eur Radiol , vol.22 , pp. 51-58
    • Wuest, W.1    Anders, K.2    Schuhbaeck, A.3
  • 6
    • 77950604781 scopus 로고    scopus 로고
    • Highpitch dual-source CT angiography of the thoracic and abdominal aorta: Is simultaneous coronary artery assessment possible?
    • Goetti R, Baumuller S, Feuchtner G, et al. Highpitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible? AJR 2010; 194:938-944
    • (2010) AJR , vol.194 , pp. 938-944
    • Goetti, R.1    Baumuller, S.2    Feuchtner, G.3
  • 7
    • 12544253582 scopus 로고    scopus 로고
    • Aortoiliac multidetector-row CT angiography with low kV settings: Improved vessel enhancement and simultaneous reduction of radiation dose
    • Wintersperger B, Jakobs T, Herzog P, et al. Aortoiliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 2005; 15:334-341
    • (2005) Eur Radiol , vol.15 , pp. 334-341
    • Wintersperger, B.1    Jakobs, T.2    Herzog, P.3
  • 8
    • 30844453160 scopus 로고    scopus 로고
    • Low-dose multidetector-row CT angiography of the infrarenal aorta and lower extremity vessels: Image quality and diagnostic accuracy in comparison with standard DSA
    • Fraioli F, Catalano C, Napoli A, et al. Low-dose multidetector-row CT angiography of the infrarenal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA. Eur Radiol 2006; 16:137-146
    • (2006) Eur Radiol , vol.16 , pp. 137-146
    • Fraioli, F.1    Catalano, C.2    Napoli, A.3
  • 9
    • 79958765730 scopus 로고    scopus 로고
    • Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair
    • Iezzi R, Cotroneo A, Giammarino A, Spigonardo F, Storto M. Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair. Eur J Radiol 2011; 79:21-28
    • (2011) Eur J Radiol , vol.79 , pp. 21-28
    • Iezzi, R.1    Cotroneo, A.2    Giammarino, A.3    Spigonardo, F.4    Storto, M.5
  • 11
    • 33846667184 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm: Can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose?
    • Macari M, Chandarana H, Schmidt B, Lee J, Lamparello P, Babb J. Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 2006; 241:908-914
    • (2006) Radiology , vol.241 , pp. 908-914
    • Macari, M.1    Chandarana, H.2    Schmidt, B.3    Lee, J.4    Lamparello, P.5    Babb, J.6
  • 12
    • 0032603548 scopus 로고    scopus 로고
    • Dose reduction in CT by on-line tube current control: Principles and validation on phantoms and cadavers
    • Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz WA. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers. Eur Radiol 1999; 9:323-328
    • (1999) Eur Radiol , vol.9 , pp. 323-328
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3    Gies, M.4    Greess, H.5    Bautz, W.A.6
  • 13
    • 81855170190 scopus 로고    scopus 로고
    • Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: Improved dose effectiveness
    • Winklehner A, Goetti R, Baumueller S, et al. Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness. Invest Radiol 2011; 46:767-773
    • (2011) Invest Radiol , vol.46 , pp. 767-773
    • Winklehner, A.1    Goetti, R.2    Baumueller, S.3
  • 14
    • 0036720964 scopus 로고    scopus 로고
    • Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CT
    • Awai K, Takada K, Onishi H, Hori S. Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT. Radiology 2002; 224:757-763
    • (2002) Radiology , vol.224 , pp. 757-763
    • Awai, K.1    Takada, K.2    Onishi, H.3    Hori, S.4
  • 15
    • 22544474645 scopus 로고    scopus 로고
    • Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation
    • Cademartiri F, Mollet NR, van der Lugt A, et al. Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. Radiology 2005; 236:661-665
    • (2005) Radiology , vol.236 , pp. 661-665
    • Cademartiri, F.1    Mollet, N.R.2    Van Der Lugt, A.3
  • 16
    • 15744394375 scopus 로고    scopus 로고
    • Multiphase contrast-enhanced CT of the liver with a multislice CT scanner: Effects of iodine concentration and delivery rate
    • Itoh S, Ikeda M, Achiwa M, Satake H, Ota T, Ishigaki T. Multiphase contrast-enhanced CT of the liver with a multislice CT scanner: effects of iodine concentration and delivery rate. Radiat Med 2005; 23:61-69
    • (2005) Radiat Med , vol.23 , pp. 61-69
    • Itoh, S.1    Ikeda, M.2    Achiwa, M.3    Satake, H.4    Ota, T.5    Ishigaki, T.6
  • 17
    • 25844494373 scopus 로고    scopus 로고
    • High-concentration contrast media in multiphasic abdominal multidetector-row computed tomography: Effect of increased iodine flow rate on parenchymal and vascular enhancement
    • Schoellnast H, Brader P, Oberdabernig B, et al. High-concentration contrast media in multiphasic abdominal multidetector-row computed tomography: effect of increased iodine flow rate on parenchymal and vascular enhancement. J Comput Assist Tomogr 2005; 29:582-587
    • (2005) J Comput Assist Tomogr , vol.29 , pp. 582-587
    • Schoellnast, H.1    Brader, P.2    Oberdabernig, B.3
  • 18
    • 19844375206 scopus 로고    scopus 로고
    • MDCT of hypervascular hepatocellular carcinomas: A prospective study using contrast materials with different iodine concentrations
    • Yagyu Y, Awai K, Inoue M, et al. MDCT of hypervascular hepatocellular carcinomas: a prospective study using contrast materials with different iodine concentrations. AJR 2005; 184:1535-1540
    • (2005) AJR , vol.184 , pp. 1535-1540
    • Yagyu, Y.1    Awai, K.2    Inoue, M.3
  • 19
    • 33748535757 scopus 로고    scopus 로고
    • Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT
    • Setty BN, Sahani DV, Ouellette-Piazzo K, Hahn PF, Shepard JAO. Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT. J Comput Assist Tomogr 2006; 30:818-822
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 818-822
    • Setty, B.N.1    Sahani, D.V.2    Ouellette-Piazzo, K.3    Hahn, P.F.4    Shepard, J.A.O.5
  • 20
    • 75349092506 scopus 로고    scopus 로고
    • Lowtube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
    • Marin D, Nelson RC, Schindera ST, et al. Lowtube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience. Radiology 2010; 254:145-153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 21
    • 27744501240 scopus 로고    scopus 로고
    • Abdominal CT with low tube voltage: Preliminary observations about radiation dose, contrast enhancement, image quality, and noise
    • Nakayama Y, Awai K, Funama Y, et al. Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 2005; 237:945-951
    • (2005) Radiology , vol.237 , pp. 945-951
    • Nakayama, Y.1    Awai, K.2    Funama, Y.3
  • 22
    • 84861313684 scopus 로고    scopus 로고
    • Low-dose multidetector CT angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease
    • Iezzi R, Santoro M, Marano R, et al. Low-dose multidetector CT angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease. Radiology 2012; 263:287-298
    • (2012) Radiology , vol.263 , pp. 287-298
    • Iezzi, R.1    Santoro, M.2    Marano, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.