메뉴 건너뛰기




Volumn 179, Issue , 2013, Pages 194-200

New label free CA125 detection based on gold nanostructured screen-printed electrode

Author keywords

CA125; Gold nanoparticles; Impedimetric immunosensor; Screen printed electrode; Tumour marker

Indexed keywords

ELECTRODES; FIBER OPTIC SENSORS; GOLD; GRAPHITE ELECTRODES; METAL NANOPARTICLES; NANOPARTICLES; TUMORS;

EID: 84880921300     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.10.017     Document Type: Article
Times cited : (107)

References (38)
  • 2
    • 64049096712 scopus 로고    scopus 로고
    • The footprints of cancer development: Cancer biomarkers
    • M.F. Ullah, M. Aatif, The footprints of cancer development: cancer biomarkers, Cancer Treatment Reviews 35 (3) (2009) 193-200.
    • (2009) Cancer Treatment Reviews , vol.35 , Issue.3 , pp. 193-200
    • Ullah, M.F.1    Aatif, M.2
  • 4
    • 33645220216 scopus 로고    scopus 로고
    • Development of biosensors for cancer clinical testing
    • A. Rasooly, J. Jacobson, Development of biosensors for cancer clinical testing, Biosensors and Bioelectronics 21 (2006) 1851-1858.
    • (2006) Biosensors and Bioelectronics , vol.21 , pp. 1851-1858
    • Rasooly, A.1    Jacobson, J.2
  • 5
    • 78650701076 scopus 로고    scopus 로고
    • A new electrochemical multiplexed assay for PSA cancer marker detection
    • A. Zani, S. Laschi, M. Mascini, G. Marrazza, A new electrochemical multiplexed assay for PSA cancer marker detection, Electroanalysis 23 (2011) 91-99.
    • (2011) Electroanalysis , vol.23 , pp. 91-99
    • Zani, A.1    Laschi, S.2    Mascini, M.3    Marrazza, G.4
  • 7
    • 34548770067 scopus 로고    scopus 로고
    • Electrochemical immunoassay for carbohydrate antigen-125 based on polythionine and gold hollow microspheres modified glassy carbon electrodes
    • X.-H. Fu, Electrochemical immunoassay for carbohydrate antigen-125 based on polythionine and gold hollow microspheres modified glassy carbon electrodes, Electroanalysis 19 (2007) 1831-1839.
    • (2007) Electroanalysis , vol.19 , pp. 1831-1839
    • Fu, X.-H.1
  • 9
    • 77953362978 scopus 로고    scopus 로고
    • Nanotechniques in proteomics: Current status, promises and challenges
    • S. Ray, H. Chandra, S. Srivastava, Nanotechniques in proteomics: current status, promises and challenges, Biosensors and Bioelectronics 25 (2010) 2389-2401.
    • (2010) Biosensors and Bioelectronics , vol.25 , pp. 2389-2401
    • Ray, S.1    Chandra, H.2    Srivastava, S.3
  • 10
    • 79960643499 scopus 로고    scopus 로고
    • Biosensors in clinical chemistry-2011 update
    • Paul D'Orazio, Biosensors in clinical chemistry-2011 update, Clinica Chimica Acta 412 (2011) 1749-1761.
    • (2011) Clinica Chimica Acta , vol.412 , pp. 1749-1761
    • D'Orazio, P.1
  • 11
    • 67650073108 scopus 로고    scopus 로고
    • Protein chips and nanomaterials for application in tumor marker immunoassays
    • H. Chen, C. Jiang, C. Yu, S. Zhang, B. Liu, J. Kong, Protein chips and nanomaterials for application in tumor marker immunoassays, Biosensors and Bioelectronics 24 (2009) 3399-3411.
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 3399-3411
    • Chen, H.1    Jiang, C.2    Yu, C.3    Zhang, S.4    Liu, B.5    Kong, J.6
  • 12
    • 34147162372 scopus 로고    scopus 로고
    • An amperometric immunosensor for separation-free immunoassay of CA125 based on its covalent immobilization coupled with thionine on carbon nanofiber
    • DOI 10.1016/j.jim.2007.01.026, PII S0022175907000506
    • L. Wu, F. Yan, H. Ju, An amperometric immunosensor for separation-free immunoassay of CA125 based on its covalent immobilization coupled with thionine on carbon nanofiber, Journal of Immunological Methods 322 (2007) 12-19. (Pubitemid 46560586)
    • (2007) Journal of Immunological Methods , vol.322 , Issue.1-2 , pp. 12-19
    • Wu, L.1    Yan, F.2    Ju, H.3
  • 13
    • 75849121386 scopus 로고    scopus 로고
    • Poly(amidoamine) dendrimer-functionalized magnetic beads as an immunosensing probe for electrochemical immunoassay for carbohydrate antigen-125 in human serum
    • X.-H. Fu, Poly(amidoamine) dendrimer-functionalized magnetic beads as an immunosensing probe for electrochemical immunoassay for carbohydrate antigen-125 in human serum, Analytical Letters 43 (2010) 455-465.
    • (2010) Analytical Letters , vol.43 , pp. 455-465
    • Fu, X.-H.1
  • 14
    • 0019790278 scopus 로고
    • Reactivity of a monoclonal antibody with human ovarian carcinoma
    • R.C. Bast, M. Feeney, H. Lazarus, L.M. Nadler, R.B. Colvin, R.C. Knapp, Reactivity of a monoclonal antibody with human ovarian carcinoma, The Journal of Clinical Investigation 68 (1981) 1331-1337. (Pubitemid 12235035)
    • (1981) Journal of Clinical Investigation , vol.68 , Issue.5 , pp. 1331-1337
    • Bast Jr., R.C.1    Feeney, M.2    Lazarus, H.3
  • 15
    • 0035920171 scopus 로고    scopus 로고
    • Molecular cloning of the CA125 ovarian cancer antigen
    • B.W.T. Yin, K.O. Lloyd, Molecular cloning of the CA125 ovarian cancer antigen, Journal of Biological Chemistry 276 (2001) 27371.
    • (2001) Journal of Biological Chemistry , vol.276 , pp. 27371
    • Yin, B.W.T.1    Lloyd, K.O.2
  • 16
    • 0036222803 scopus 로고    scopus 로고
    • The significance of serum CA 125 elevation in malignant and nonmalignant diseases
    • DOI 10.1006/gyno.2002.6603
    • K. Sjövall, B. Nilsson, N. Einhorn, The significance of serum CA 125 elevation in malignant and nonmalignant diseases, Gynecologic Oncology 85 (2002) 175-178. (Pubitemid 34304030)
    • (2002) Gynecologic Oncology , vol.85 , Issue.1 , pp. 175-178
    • Sjovall, K.1    Nilsson, B.2    Einhorn, N.3
  • 17
    • 33645983368 scopus 로고    scopus 로고
    • Electrochemical immuno-bioanalysis for carcinoma antigen 125 based on thionine and gold nanoparticles-modified carbon paste interface
    • D. Tang, R. Yuan, Y. Chai, Electrochemical immuno-bioanalysis for carcinoma antigen 125 based on thionine and gold nanoparticles-modified carbon paste interface, Analytica Chimica Acta 564 (2006) 158-165.
    • (2006) Analytica Chimica Acta , vol.564 , pp. 158-165
    • Tang, D.1    Yuan, R.2    Chai, Y.3
  • 18
    • 34548480491 scopus 로고    scopus 로고
    • A disposable two-throughput electrochemical immunosensor chip for simultaneous multianalyte determination of tumor markers
    • DOI 10.1016/j.bios.2007.03.023, PII S0956566307001893
    • J. Wu, Z. Zhang, Z. Fu, H. Ju, A disposable two-throughput electrochemical immunosensor chip for simultaneous multianalyte determination of tumor markers, Biosensors and Bioelectronics 23 (2007) 114-120. (Pubitemid 47375094)
    • (2007) Biosensors and Bioelectronics , vol.23 , Issue.1 , pp. 114-120
    • Wu, J.1    Zhang, Z.2    Fu, Z.3    Ju, H.4
  • 19
    • 70349506773 scopus 로고    scopus 로고
    • Electrochemical sensing platform based on tris(2,2′-bipyridyl) cobalt(III) and multiwall carbon nanotubes-Nafion composite for immunoassay of carcinoma antigen-125
    • S. Chen, R. Yuan, Y. Chai, L. Min, W. Li, Y. Xu, Electrochemical sensing platform based on tris(2,2′-bipyridyl)cobalt(III) and multiwall carbon nanotubes-Nafion composite for immunoassay of carcinoma antigen-125, Electrochimica Acta 54 (2009) 7242-7247.
    • (2009) Electrochimica Acta , vol.54 , pp. 7242-7247
    • Chen, S.1    Yuan, R.2    Chai, Y.3    Min, L.4    Li, W.5    Xu, Y.6
  • 20
    • 79951615475 scopus 로고    scopus 로고
    • Protein detection using arrayed microsensor chips: Tuning sensor footprint to achieve ultrasensitive readout of CA-125 in serum and whole blood
    • J. Das, S.O. Kelley, Protein detection using arrayed microsensor chips: tuning sensor footprint to achieve ultrasensitive readout of CA-125 in serum and whole blood, Analytical Chemistry 83 (2011) 1167-1172.
    • (2011) Analytical Chemistry , vol.83 , pp. 1167-1172
    • Das, J.1    Kelley, S.O.2
  • 21
    • 84861576780 scopus 로고    scopus 로고
    • Electrochemiluminescence of CdSe quantum dots for highly sensitive competitive immunosensing
    • X. Fang, M. Han, G. Lu, W. Tu, Z. Dai, Electrochemiluminescence of CdSe quantum dots for highly sensitive competitive immunosensing, Sensors and Actuators B: Chemical 168 (2012) 271-276.
    • (2012) Sensors and Actuators B: Chemical , vol.168 , pp. 271-276
    • Fang, X.1    Han, M.2    Lu, G.3    Tu, W.4    Dai, Z.5
  • 23
    • 79959251955 scopus 로고    scopus 로고
    • Ultra trace analysis of small molecule by label-free impedimetric immunosensor using multilayer modified electrode
    • K. Chullasat, P. Kanatharana, W. Limbut, A. Numnuam, P. Thavarungkul, Ultra trace analysis of small molecule by label-free impedimetric immunosensor using multilayer modified electrode, Biosensors and Bioelectronics 26 (2011) 4571-4578.
    • (2011) Biosensors and Bioelectronics , vol.26 , pp. 4571-4578
    • Chullasat, K.1    Kanatharana, P.2    Limbut, W.3    Numnuam, A.4    Thavarungkul, P.5
  • 24
    • 69249219069 scopus 로고    scopus 로고
    • Electrochemical and spectroscopic characterization of screen-printed gold-based electrodes modified with self-assembled monolayers and Tc85 protein
    • P. Ferreira, C.S. Fugivara, S. Barrozo, P.H. Suegama, H. Yamanaka, V. Benedetti, Electrochemical and spectroscopic characterization of screen-printed gold-based electrodes modified with self-assembled monolayers and Tc85 protein, Journal of Electroanalytical Chemistry 634 (2009) 111-122.
    • (2009) Journal of Electroanalytical Chemistry , vol.634 , pp. 111-122
    • Ferreira, P.1    Fugivara, C.S.2    Barrozo, S.3    Suegama, P.H.4    Yamanaka, H.5    Benedetti, V.6
  • 25
    • 14644444164 scopus 로고    scopus 로고
    • Enzyme-based impedimetric detection of PCR products using oligonucleotide-modified screen-printed gold electrodes
    • DOI 10.1016/j.bios.2004.08.025, PII S0956566304003914
    • F. Lucarelli, G. Marrazza, M. Mascini, Enzyme-based impedimetric detection of PCR products using oligonucleotide-modified screen-printed gold electrodes, Biosensors and Bioelectronics 20 (10) (2005) 2001-2009. (Pubitemid 40312096)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.10 SPEC. ISS. , pp. 2001-2009
    • Lucarelli, F.1    Marrazza, G.2    Mascini, M.3
  • 27
    • 65749110687 scopus 로고    scopus 로고
    • Aligned carbon nanotube thin films for DNA electrochemical sensing
    • F. Berti, L. Lozzi, I. Palchetti, S. Santucci, G. Marrazza, Aligned carbon nanotube thin films for DNA electrochemical sensing, Electrochimica Acta 54 (22) (2009) 5035-5041.
    • (2009) Electrochimica Acta , vol.54 , Issue.22 , pp. 5035-5041
    • Berti, F.1    Lozzi, L.2    Palchetti, I.3    Santucci, S.4    Marrazza, G.5
  • 30
    • 79959718320 scopus 로고    scopus 로고
    • Evaluation of a modified carbon micromesh electrode as a new substrate for electrochemical immunosensing
    • D. Rathod, S. Warren, K. Keane, D.a. Egan, E. Dempsey, Evaluation of a modified carbon micromesh electrode as a new substrate for electrochemical immunosensing, Analytical Methods 3 (2011) 799.
    • (2011) Analytical Methods , vol.3 , pp. 799
    • Rathod, D.1    Warren, S.2    Keane, K.3    Egan, D.A.4    Dempsey, E.5
  • 31
    • 0028936621 scopus 로고
    • Expression of the prostate-specific antigen gene by a primary ovarian carcinoma
    • H. Yu, E.P. Diamandis, M. Levesque, S.L. Asa, M. Monne, C.M. Croce, Expression of the prostate-specific antigen gene by a primary ovarian carcinoma, Cancer Research 55 (1995) 1603-1606.
    • (1995) Cancer Research , vol.55 , pp. 1603-1606
    • Yu, H.1    Diamandis, E.P.2    Levesque, M.3    Asa, S.L.4    Monne, M.5    Croce, C.M.6
  • 32
    • 52149108482 scopus 로고    scopus 로고
    • Serum CA125 and PSA concentrations in patients with lymphoma
    • P. Wiernik, Serum CA125 and PSA concentrations in patients with lymphoma, Clinical Advances in Hematology and Oncology 6 (2008) 527-531.
    • (2008) Clinical Advances in Hematology and Oncology , vol.6 , pp. 527-531
    • Wiernik, P.1
  • 33
    • 36348970486 scopus 로고    scopus 로고
    • Synthesis of gold nanotadpoles by a temperature-reducing seed approach and the dielectrophoretic manipulation
    • DOI 10.1021/jp072969g
    • L. Huang, M. Wang, Y. Zhang, Z. Guo, J. Sun, N. Gu, Synthesis of gold nanotadpoles by a temperature-reducing seed approach and the dielectrophoretic manipulation, Journal of Physical Chemistry C 111 (2007) 16154-16160. (Pubitemid 350149943)
    • (2007) Journal of Physical Chemistry C , vol.111 , Issue.44 , pp. 16154-16160
    • Huang, L.1    Wang, M.2    Zhang, Y.3    Guo, Z.4    Sun, J.5    Gu, N.6
  • 34
    • 65349172489 scopus 로고    scopus 로고
    • Electrocatalytic behavior and amperometric detection of morphine on ITO electrode modified with directly electrodeposited gold nanoparticles
    • Y. Zhao, Y. Wu, Y. Zhang, Z. Chen, X. Cao, J. Di, et al., Electrocatalytic behavior and amperometric detection of morphine on ITO electrode modified with directly electrodeposited gold nanoparticles, Electroanalysis 21 (2009) 939-943.
    • (2009) Electroanalysis , vol.21 , pp. 939-943
    • Zhao, Y.1    Wu, Y.2    Zhang, Y.3    Chen, Z.4    Cao, X.5    Di, J.6
  • 35
    • 34247248352 scopus 로고    scopus 로고
    • An acetylcholinesterase enzyme electrode stabilized by an electrodeposited gold nanoparticle layer
    • DOI 10.1016/j.elecom.2006.11.021, PII S1388248106005431
    • O. Shulga, J.R. Kirchhoff, An acetylcholinesterase enzyme electrode stabilized by an electrodeposited gold nanoparticle layer, Electrochemistry Communications 9 (2007) 935-940. (Pubitemid 46617369)
    • (2007) Electrochemistry Communications , vol.9 , Issue.5 , pp. 935-940
    • Shulga, O.1    Kirchhoff, J.R.2
  • 37
    • 0028017255 scopus 로고
    • Voltammetric studies of composite ceramic carbon working electrodes
    • DOI 10.1016/0003-2670(94)80309-9
    • G. Gun, M. Tsionsky, O. Lev, Voltammetric studies of composite ceramic carbon working electrodes, Analytica Chimica Acta 294 (1994) 261-270. (Pubitemid 24264592)
    • (1994) Analytica Chimica Acta , vol.294 , Issue.3 , pp. 261-270
    • Gun, G.1    Tsionsky, M.2    Lev, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.